Written and maintained by CASRAI Editorial Board
Published · Last updated
On this page
An amplicon sequence variant (ASV) is a DNA sequence inferred from amplicon sequencing reads after sequencing errors have been modelled and removed, so that it is resolved exactly, down to single-nucleotide differences, instead of being merged into a cluster of similar reads. ASVs are the unit that denoising methods such as DADA2 and Deblur report; the older unit, the operational taxonomic unit (OTU), is a cluster of reads that differ by less than a fixed threshold, most commonly 3%.
Definition and scope: what is an amplicon, and what is an ASV?
What is an amplicon?
An amplicon is a piece of DNA produced by PCR amplification of a chosen target region. Illumina describes amplicon sequencing as the ultra-deep sequencing of PCR products, which allows efficient variant identification, and notes that it supports multiplexing of hundreds to thousands of amplicons per reaction. The same page lists two typical uses: finding rare somatic mutations in complex samples such as tumours mixed with germline DNA, and 16S rRNA sequencing, “a common amplicon sequencing method used to identify and compare bacteria within a given sample.” In marker-gene work the amplified region is a barcode: 16S for bacteria, ITS for fungi and 18S for eukaryotes (Callahan et al., Nature Methods 2016).
What is an ASV?
Callahan, McMurdie and Holmes (ISME Journal 2017) define ASVs as sequence variants that “can be resolved exactly, down to the level of single-nucleotide differences” over the sequenced gene region. They are inferred from the data alone, so the label is the DNA sequence itself. The authors argue that this makes ASVs consistent labels with intrinsic biological meaning that stay comparable “into the indefinite future”, independent of any reference database. Because the same exact sequence receives the same label in every study that amplifies the same region, ASV tables from separate studies can be merged.
How ASVs are inferred in practice
ASV methods work by denoising. Per Callahan et al. (2017), they “infer the biological sequences in the sample prior to the introduction of amplification and sequencing errors”. Real biological sequences are separated from erroneous ones partly because real sequences are more likely to be observed repeatedly than error-containing sequences. Inference is done per sample rather than read by read, which is why the computing cost grows linearly with the number of samples while memory use stays flat, and why samples can be processed in parallel.
Three denoising methods are named in the primary literature that this page draws on:
- DADA2 (Callahan et al., Nature Methods 2016) resolves differences of as little as one nucleotide from Illumina amplicon data. In the mock communities the authors tested, it identified more real variants and fewer spurious sequences than the other methods compared.
- Deblur (Amir et al., mSystems 2017) uses error profiles to obtain putative error-free sequences from Illumina MiSeq or HiSeq data. The authors call the output sub-OTUs (sOTUs) and note that clinical, food-safety and some ecological uses need this higher specificity.
- UNOISE (Edgar 2016) and minimum entropy decomposition (Eren et al. 2015) are cited by Callahan et al. (2017) as related approaches; this page does not compare their performance.
For the workflow side, the QIIME 2 guide covers a platform in which ASV inference is one step, and the guide to read length explains why the length of the sequenced region matters for exact-variant resolution.
ASVs vs OTUs vs sOTUs
What are ASVs and OTUs, and how do they differ?
The difference is in how the unit is defined. An OTU is defined by clustering reads under a fixed dissimilarity threshold, typically 3% (Callahan et al. 2016). Clustering lumps nearby sequences together, which reduces the chance that sequencing errors are read as real variation, but it precludes seeing fine-scale variation. Callahan et al. (2017) distinguish two OTU strategies: closed-reference OTUs, matched against a reference database, and de novo OTUs, clustered within one dataset. An ASV is defined by the exact sequence after error removal, with no threshold and no dependence on a reference database.
Callahan et al. (2017) argue that ASVs combine the strengths of both OTU strategies. Closed-reference OTUs have computational cost that scales linearly with study size, allow independently processed datasets to be merged, and support forward prediction. De novo OTUs measure diversity accurately and work where reference databases are shallow. The authors conclude that ASVs should replace OTUs as the standard unit of marker-gene analysis. The data table below sets the approaches side by side.
Where ASVs matter for labs and research offices
Merging and reusing results across studies
Per Callahan et al. (2017), ASV tables from different studies can be merged simply only when they come from the same genetic locus. If two projects used overlapping but not identical primer sets, the sequences must be trimmed to the shared region before comparison, and batch effects from methodological differences should still be considered. For a lab, that makes the primer pair and sequenced region part of the data record. The 27F and 1492R primer guide describes one common bacterial primer pair, and the Earth Microbiome Project’s standard 16S protocol instead targets the V4 region with the 515F-Y and 806R primers and recommends a 5-10% PhiX spike-in on Illumina platforms because amplicon libraries have low base diversity.
Choosing a sequencing provider or a platform
If a core facility or an outside provider will deliver the sequences, the amplified region, read length and the method used to infer variants should be stated in the service agreement so that ASVs from different batches can be compared. The next-generation sequencing service procurement guide covers the commercial side, including 16S rRNA sequencing services. For the wider context of marker-gene work versus shotgun approaches, see the metagenomics guide.
Common misunderstandings
The table below turns the documented caveats into a quick check for reading an ASV table; each row traces to the source in the last column.
| Caveat | What the source states | Source |
|---|---|---|
| Several ASVs from one genome | The same genome can contain multiple ASVs when the targeted locus has multiple copies. | Callahan et al. 2017 |
| Short barcode, limited taxonomic meaning | No guarantee of ecological coherence or even monophyly among genomes sharing a sequence variant. | Callahan et al. 2017 |
| Merging studies | Tables merge simply only for the same locus; overlapping primer sets need trimming to the shared region; batch effects should be considered. | Callahan et al. 2017 |
| Copy number versus cells | Bacterial 16S copy number ranges from 1 to 15 per genome and archaeal from 1 to 4; the rrnDB authors caution that a single mean copy number can mislead. | Stoddard et al. 2015 (rrnDB), read 2026-11-21 |
| Identity not enough for clinical identification | Secondary loci such as rpoB, gyrB or secA1 are required when 16S sequences are identical across species. | CLSI MM18 |
- “One ASV equals one species.” It does not. Callahan et al. (2017) state that “the same genome can contain multiple ASVs if there are multiple copies of the targeted genetic locus”, and that a short barcode gives “no guarantee of ecological coherence or even monophyly among genomes” sharing a sequence variant.
- “ASV counts are cell counts.” The rrnDB database (Stoddard et al. 2015; Roller et al. 2016) catalogues 16S rRNA gene copy numbers of 1 to 15 per bacterial genome and 1 to 4 in archaea. Uncorrected amplicon read counts therefore reflect operon counts as well as cells.
- “ASVs need a reference database.” They do not for inference. A database is needed only afterwards, to assign taxonomy.
- “Denoising removes every error.” Denoising infers the most likely true sequences; it is a statistical inference per sample, not a guarantee. DADA2’s reported advantage was measured on mock communities with known composition.
Frequently asked questions
What is an amplicon?
An amplicon is a DNA fragment produced by PCR amplification of a chosen target region. Amplicon sequencing is the deep sequencing of these PCR products; Illumina notes that it can multiplex hundreds to thousands of amplicons per reaction.
What are ASVs and OTUs?
OTUs are clusters of reads that differ by less than a fixed threshold, usually 3%. ASVs are exact sequences inferred after removing sequencing errors, resolved to single-nucleotide differences. Callahan et al. (2017) recommend ASVs as the standard unit.
What are the limitations of 16S amplicon sequencing?
Four limits are documented in the sources read for this page. First, a short barcode region cannot guarantee that sequences sharing a variant are ecologically coherent or monophyletic (Callahan et al. 2017). Second, one genome can carry several different copies of the 16S gene, giving several ASVs, and copy number ranges from 1 to 15 per bacterial genome in rrnDB, so read counts are not cell counts. Third, results from different primer sets can be merged only after trimming to the shared region, and batch effects remain. Fourth, for clinical identification the CLSI guideline MM18 states that percentage identity alone is insufficient across divergent bacterial genera and calls for secondary loci such as rpoB, gyrB or secA1 when 16S sequences are identical between species, as in the Mycobacterium tuberculosis complex.
What are the key differences between Sanger sequencing and amplicon sequencing?
The two are not opposites: amplicon sequencing reads PCR products, and Sanger sequencing can read a single PCR product too. The difference is scale and what is being read. Sanger sequencing, with capillary electrophoresis, returns roughly 700-900 high-quality bases from one reaction and is used to confirm a known stretch of DNA; see the Sanger sequencing guide. Thermo Fisher’s MicroSEQ kits apply it to the 16S gene of one bacterial isolate. Next-generation amplicon sequencing instead reads very large numbers of PCR products in parallel, which is what makes it suitable for mixed communities and rare variants (Illumina), and it is what generates the many reads that denoising methods turn into ASVs.
Do I need a reference database to get ASVs?
No. ASVs are identified independently of a reference database (Callahan et al. 2017). A database such as SILVA is used only to assign taxonomy to the resulting sequences.
Sources
- Callahan BJ, McMurdie PJ, Holmes SP. Exact sequence variants should replace operational taxonomic units in marker-gene data analysis. ISME J 2017;11:2639-2643. PMC5702726, read 2026-11-21.
- Callahan BJ et al. DADA2: high-resolution sample inference from Illumina amplicon data. Nat Methods 2016. PMC4927377, read 2026-11-21.
- Amir A et al. Deblur rapidly resolves single-nucleotide community sequence patterns. mSystems 2017;2:e00191-16. PMC5340863, read 2026-11-21.
- Illumina. Amplicon sequencing, read 2026-11-21.
- Stoddard SF et al. 2015 and Roller BRK et al. 2016, rrnDB (ribosomal RNA operon copy number database), as summarised in the CASRAI fact record read 2026-11-15.
- CLSI MM18, Interpretive Criteria for Identification of Bacteria and Fungi by Targeted DNA Sequencing, 2nd edition, as summarised in the CASRAI fact record read 2026-11-15.
- Earth Microbiome Project 16S Illumina amplicon protocol, as summarised in the CASRAI fact record read 2026-11-15.
Data: Marker-gene sequence units compared: closed-reference OTU, de novo OTU, ASV and sOTU
Compares how four units used in amplicon (marker-gene) sequencing analysis are defined, whether they depend on a reference database, and the advantages the primary literature states for each. Compiled from Callahan et al. 2017 (ISME J), Callahan et al. 2016 (Nat Methods) and Amir et al. 2017 (mSystems).
| Unit | How it is defined | Depends on a reference database | Advantages stated in the source | Primary source |
|---|---|---|---|---|
| Closed-reference OTU | Reads matched to a reference database and grouped under a fixed dissimilarity threshold (typically 3%) | Yes | Computational cost scales linearly with study size; independently processed datasets merge simply; supports forward prediction | Callahan et al. 2017 |
| De novo OTU | Reads clustered within one dataset under a fixed dissimilarity threshold (typically 3%) | No | Accurate diversity measurement; works where reference databases are shallow | Callahan et al. 2017 |
| ASV (exact sequence variant) | Exact sequence inferred after modelling and removing amplification and sequencing errors, resolved to single-nucleotide differences | No (identified independently of a database) | Combines the advantages of both OTU strategies; consistent labels across studies; computation scales linearly with samples | Callahan et al. 2017; Callahan et al. 2016 |
| sOTU (Deblur output) | Putative error-free sequences obtained with error profiles from Illumina MiSeq or HiSeq data | No | Single-nucleotide resolution for uses needing higher specificity, such as clinical and food-safety work | Amir et al. 2017 |
Sources
- Exact sequence variants should replace operational taxonomic units in marker-gene data analysis (accessed 2026-11-21)
- DADA2: high-resolution sample inference from Illumina amplicon data (accessed 2026-11-21)
- Deblur rapidly resolves single-nucleotide community sequence patterns (accessed 2026-11-21)
Compiled by CASRAI from the sources above. Free to reuse under CC BY 4.0 with attribution.







