Written and maintained by CASRAI Editorial Board
Published
On this page
An argon safety data sheet (SDS) describes a gas that is not classified as toxic, is non-flammable and lists no reactivity hazard, so its hazards are physical: a cylinder holding gas under pressure (GHS hazard statement H280) and a gas that can displace oxygen in the room and cause suffocation. Two supplier SDSs read for this page, a US Praxair sheet and an Air Liquide sheet in the EU format, both classify compressed argon as “Compressed gas”, signal word “Warning”, with CAS number 7440-37-1.
Definition and scope: what an argon SDS covers
A safety data sheet is the supplier document that US employers must keep for each hazardous chemical in the workplace. OSHA’s Hazard Communication Standard (29 CFR 1910.1200, paragraph (g)(2)) lists sixteen sections in a fixed order, from Section 1 (Identification) through Section 8 (Exposure controls/personal protection), Section 13 (Disposal considerations) and Section 14 (Transport information) to Section 16 (Other information, including the date of preparation or last revision). Our guide to how to read a safety data sheet walks through all sixteen; this page applies them to one gas.
“Argon SDS” covers more than one product. Suppliers publish separate sheets for compressed argon in cylinders and for refrigerated (liquid) argon, and some sheets describe argon mixtures such as argon with carbon dioxide. The two sheets compared below are for pure compressed argon. The refrigerated liquid has an additional hazard statement, covered under the types section.
Everything on this page is a summary of published sheets and a public chemical database for lab staff and EHS officers who need to understand what the sheet is telling them. The sheet from your own supplier, for the product you actually receive, is the document that governs your site, and sheets differ between suppliers and between regions.
What an argon SDS says, section by section
Section 2: hazard identification and GHS classification
The Praxair sheet (P-4563, written to 29 CFR 1910.1200, revision date printed as 10/03/2014) gives the GHS-US classification as “Compressed gas”, H280, with the signal word “Warning”. H280 reads “CONTAINS GAS UNDER PRESSURE; MAY EXPLODE IF HEATED”. It adds an OSHA-specific statement, OSHA-H01: “MAY DISPLACE OXYGEN AND CAUSE RAPID SUFFOCATION.” The precautionary statements include P271+P403 (use and store outdoors or in a well-ventilated place) and several Compressed Gas Association (CGA) statements: use a back-flow preventive device in the piping (CGA-PG05), use equipment rated for cylinder pressure (CGA-PG10), close the valve after each use and when empty (CGA-PG06), and protect from sunlight when the ambient temperature exceeds 52 °C (125 °F) (CGA-PG02). The same section records “Asphyxiant in high concentrations” as another hazard that does not contribute to the classification.
The Air Liquide sheet (reference EIGA003A, version 1.1, revision date 26 July 2019) uses the EU CLP format. It classifies argon as “Gases under pressure: Compressed gas”, H280, signal word “Warning”, with storage statement P410+P403 (protect from sunlight; store in a well-ventilated place). Its suffocation language sits in the section on other hazards rather than in a hazard statement: asphyxiant in high concentrations, symptoms that may include loss of mobility or consciousness, and a warning that the victim may not be aware of the asphyxiation.
Section 8: exposure controls and PPE
This is the section that surprises people. The Praxair sheet lists the ACGIH and OSHA exposure limits as “Not established”. The Air Liquide sheet lists no derived no-effect level (DNEL) or predicted no-effect concentration (PNEC) for argon. Because argon is not a toxicant, the controls are about the atmosphere, not about skin or eye contact with the gas: oxygen detectors where asphyxiating gases may be released, adequate ventilation, and a permit-to-work or work permit system for maintenance activities.
Personal protective equipment is aimed at handling cylinders and at emergencies. The Praxair sheet calls for working gloves when handling gas containers and safety glasses with side shields, and for respiratory protection under OSHA 29 CFR 1910.134 and ANSI Z88.2, with a self-contained breathing apparatus (SCBA) for emergencies or unknown exposure levels. It lists thermal hazard protection as “None necessary”. The Air Liquide sheet bases PPE on a documented risk assessment and names safety glasses with side shields (EN 166), working gloves (EN 388), safety shoes (EN ISO 20345), and SCBA or a positive-pressure airline with mask in oxygen-deficient atmospheres (EN 137).
Section 7: handling and storage
Both sheets treat the cylinder as the hazard. The Praxair sheet specifies leather safety gloves and safety shoes for cylinder handling, no dragging, rolling, sliding or dropping, valve protection cap in place, never lifting a cylinder by its cap, using a cart, and never inserting an object into the cap openings. It says to store containers in a cool, well-ventilated place where the temperature will not exceed 125 °F (52 °C), to secure them upright, to store full and empty containers separately, to use first-in, first-out stock rotation, never to work on a pressurized system, and never to place a container where it may become part of an electrical circuit. For sizes and valve outlets, see the CASRAI entries on compressed gas cylinder sizes and CGA fittings.
The Air Liquide sheet adds three instructions that the US sheet does not state in the same words: keep the container below 50 °C, keep it away from combustible materials, and prevent suck-back of water into the container. It also says to check the gas system for leaks, never to use direct flame or electrical heating to raise the pressure in a cylinder, and to close the valve after each use even when the cylinder is connected.
Section 10: stability and reactivity
The Air Liquide sheet describes argon as stable with no reactivity hazard. The Praxair “incompatible materials” entry does not name a material that reacts with argon; it notes only that welding or cutting with argon shielding can form carbon monoxide, carbon dioxide, ozone and nitrogen oxides from the arc. Those are products of the arc and the work piece, not of argon. The Praxair sheet lists decomposition products as “None”.
Sections 11 and 13: toxicology and disposal
Praxair does not classify argon for acute toxicity, and the Air Liquide sheet says adverse effects from skin or eye contact are not expected. For disposal, the Praxair sheet says the gas may be vented to the atmosphere in a well-ventilated place and must not be discharged anywhere its accumulation could be dangerous; for other questions it refers the reader to the supplier. The Air Liquide sheet allows venting in a well-ventilated place and says unused product in the original cylinder should be returned to the supplier.
Section 14: transport
The Praxair sheet gives the US Department of Transportation description “UN1006 Argon, compressed, 2.2”, a Class 2.2 non-flammable compressed gas, and Emergency Response Guide number 121. The Air Liquide sheet gives UN 1006, ADR class 2, classification code 1A, hazard identification number 20, tunnel code E and packing instruction P200. Our guide to hazard class 2.2 non-flammable gases explains what the class means for shipping.
Argon hazards: oxygen displacement and cylinder pressure
Read together, the two sheets describe the same two hazards. The first is pressure: H280 warns that the container may explode if heated, which is why both sheets set storage temperature ceilings and instruct users to protect cylinders from sunlight and heat. The second is asphyxiation: argon released into an enclosed space displaces the air, and the Air Liquide sheet notes that the person affected may not realise it is happening. That is why the sheets point to oxygen detectors and to SCBA or airline respirators for oxygen-deficient atmospheres.
The classification does not capture this second hazard consistently. The US sheet carries it in a hazard statement; the EU sheet carries it as an “other hazard” outside the classification. The practical reading for a lab is the same either way: treat argon storage and use areas as locations where oxygen monitoring and ventilation belong in the risk assessment.
Types: compressed argon, refrigerated argon and what PubChem aggregates
PubChem’s argon record (CID 23968) aggregates 643 harmonised classification and labelling reports submitted to the European Chemicals Agency (ECHA), from 10 notifications. H280 appears in 68% of the reports. H281, “Contains refrigerated gas; may cause cryogenic burns or injury”, appears in 33.3%, which reflects the refrigerated liquid form. A further 4 of 643 reports (0.6%) say the substance does not meet GHS criteria for classification. PubChem notes that the information may vary between notifications depending on impurities, additives and other factors.
The point for a lab is that “argon” on a label can mean a gas in a cylinder or a cryogenic liquid in a vessel, and the hazard statements differ. Liquid argon adds a cold-contact hazard to the pressure and asphyxiation hazards. The data table below sets the three views side by side. For a nitrogen equivalent, see the nitrogen gas SDS and liquid nitrogen SDS guides, which cover the sibling inert gas in compressed and cryogenic form.
Where it matters for labs and EHS officers
The table below turns the section-by-section read into a checklist of what each part of an argon SDS tells a lab and what it leaves for the lab to decide. Each row traces to the two sheets above.
| SDS section | What the argon sheets say | What it means for lab planning |
|---|---|---|
| 2 Hazard identification | Compressed gas, H280, Warning; asphyxiant in high concentrations | Pressure and oxygen displacement are the hazards to assess |
| 8 Exposure controls | No ACGIH or OSHA limit listed (Praxair); no DNEL or PNEC (Air Liquide); oxygen detectors and permit-to-work named | There is no concentration limit to measure against, so oxygen monitoring and ventilation carry the control |
| 8 PPE | Gloves and safety glasses with side shields; SCBA or airline respirator for oxygen-deficient atmospheres | PPE protects the handler of the cylinder and the emergency responder, not against contact with the gas |
| 7 Storage | Below 52 °C (125 °F) on the US sheet; below 50 °C on the EU sheet | Both ceilings point to keeping cylinders away from heat and sunlight |
| 10 Reactivity | Stable; the only listed concern is by-products from welding arcs | No incompatibility between argon and a stored material is stated on these sheets |
| 13 Disposal | Vent in a well-ventilated place; return unused cylinders to the supplier | The Praxair sheet refers other disposal questions to the supplier |
| 14 Transport | UN1006, Class 2.2, ERG 121 (US); ADR code 1A (EU) | Shipping follows the non-flammable gas class |
Because the two sheets were written by different suppliers under different legal formats, a lab with both US and EU suppliers will see small differences in wording, storage ceilings and which hazards sit in the classification. The sheet supplied with your own cylinders is the one to file.
Common misunderstandings
“Argon is non-toxic, so it has no hazard”
The sheets say the opposite: argon is classified as a gas under pressure, and both describe the asphyxiation hazard. A lack of toxicity removes the exposure-limit and skin-contact controls; it does not remove the pressure and oxygen-displacement hazards.
“The incompatible materials entry lists what argon reacts with”
On the Praxair sheet the entry covers by-products of welding or cutting with argon shielding, not reactions of argon itself. The Air Liquide sheet records no reactivity hazard.
“There is a limit value I can monitor against”
The Praxair sheet lists the ACGIH and OSHA limits as “Not established”, and the Air Liquide sheet lists no DNEL or PNEC. The control is therefore based on the oxygen-deficiency hazard and a risk assessment, which is why the sheets name oxygen detectors.
“Every argon SDS is identical”
Compressed and refrigerated argon are different products, and the PubChem aggregation shows classifications varying between notifications. Even the two compressed sheets differ in format, hazard wording and storage ceiling.
Where to read manufacturer argon SDSs
The two supplier sheets used here are the Praxair (now Linde) US sheet, hosted as a copy on a University of Washington laboratory safety page, and the Air Liquide sheet reference EIGA003A. Both are linked in the sources below. Suppliers update their sheets, so a copy found through a search may predate the current revision; request the current sheet from the supplier that ships your cylinders and file it with your chemical inventory.
Sources
- Praxair: Safety Data Sheet “Argon, compressed” (P-4563), hosted by the University of Washington, checked 2026-11-18
- Air Liquide: Safety Data Sheet “Argon” (EIGA003A, version 1.1), checked 2026-11-18
- National Library of Medicine, PubChem: Argon (CID 23968), GHS classification, checked 2026-11-18
- Cornell Legal Information Institute: 29 CFR 1910.1200, Hazard communication, checked 2026-11-18
Data: Argon hazard classification and handling limits across three published sources
Compares how a US Praxair safety data sheet (29 CFR 1910.1200 format), an EU Air Liquide safety data sheet (CLP format, EIGA003A) and the PubChem aggregation of ECHA classification reports describe argon: signal word, hazard statements, how the suffocation hazard is placed, listed exposure limits, storage temperature ceiling and UN transport number. Values were read from each source on 2026-11-18.
Period covered: 2014/2026.
| Source | Label system | Hazard statements | Suffocation hazard placement | Exposure limits listed | Storage temperature ceiling (degrees C) | UN number |
|---|---|---|---|---|---|---|
| Praxair SDS P-4563 (rev. 10/03/2014) | US GHS, 29 CFR 1910.1200 | H280; OSHA-H01 (may displace oxygen and cause rapid suffocation) | Hazard statement OSHA-H01, plus asphyxiant in other hazards | ACGIH and OSHA: not established | 52 | UN1006 |
| Air Liquide SDS EIGA003A (v1.1, 26/07/2019) | EU CLP | H280 | Other hazards: asphyxiant in high concentrations; victim may not be aware | No DNEL or PNEC available | 50 | UN 1006 |
| PubChem Argon CID 23968 (ECHA aggregate, 643 reports) | Aggregated ECHA C&L notifications | H280 in 68%; H281 in 33.3%; 0.6% not classified | Not stated in the GHS aggregate | Not stated in the GHS aggregate | Not stated | Not stated |
Sources
- Praxair Safety Data Sheet Argon, compressed (P-4563) (accessed 2026-11-18)
- Air Liquide Safety Data Sheet Argon (EIGA003A) (accessed 2026-11-18)
- PubChem Argon (CID 23968) (accessed 2026-11-18)
Compiled by CASRAI from the sources above. Free to reuse under CC BY 4.0 with attribution.