A blood sugar test lancet is the small, sharp tip that pricks the skin so a drop of blood can reach a glucose test strip. This guide is for clinic staff, supply buyers and students who need to know which kind of lancet is which under US regulation, and what the CDC says to look for and avoid when fingerstick testing is done for more than one person. Lancets are one part of a four-item test set: lancet, lancing device, test strip and meter. Each is shared or not shared under different rules.
What a blood sugar test lancet is
A lancet is the sharp piece that punctures the skin. The FDA describes the basic glucose test as pricking a finger with a lancet to get a drop of blood that is placed on a disposable test strip (FDA, Blood Glucose Monitoring Devices, page current as of 11/14/2024, checked 2026-11-03). The CDC calls the holder that fires the lancet a fingerstick device, also called a lancing device: it “prick[s] the skin to obtain drops of blood for testing” (CDC, Considerations for Blood Glucose Monitoring and Insulin Administration, 7 August 2024, checked 2026-11-03).
The phrase “lancet blood sugar test” in searches means the same product: the lancet used in a blood glucose test. For the lancet on its own, see what a lancet is.
Who uses it: people who test their own blood glucose, and clinic and ward staff who run fingerstick glucose checks.
How it fits in a glucose test
- Lancet: pricks the skin. The CDC says never to reuse lancets.
- Lancing device (fingerstick device): holds the lancet. The CDC says never to use fingerstick devices for more than one person.
- Test strip: receives the drop of blood. See glucose blood test strips.
- Meter: reads the strip. The CDC says to assign meters to one person where possible and not to share them; see what a glucometer is.
The general sample-taking context is covered in capillary blood collection.
Types of blood lancet and their FDA class
US regulation separates blood lancets by whether they are single use or multiple use, and by whether they serve one patient or several. 21 CFR 878.4850 lists four categories (Legal Information Institute copy of the eCFR, checked 2026-11-03).
| Type (21 CFR 878.4850) | Intended use as written | FDA class |
|---|---|---|
| (a) Single use with an integral sharps injury prevention feature | Disposable lancet intended for a single use | Class II (special controls) |
| (b) Single use without an integral sharps injury prevention feature | Disposable lancet intended for a single use | Class II (special controls) |
| (c) Multiple use, single patient only | Multiple-use-capable lancet intended for use on a single patient | Class II (special controls) |
| (d) Multiple use, multiple patients | Multiple-use-capable lancet intended for use on multiple patients | Class III (premarket approval) |
The practical reading of the table is that the only category intended for use on more than one patient is the only one placed in Class III, the class that requires premarket approval. This is a description of the regulation, not a statement about any particular product.
What the CDC says to check on lancets and devices
For fingerstick testing in healthcare settings, the CDC page cited below gives these points:
- Single-use, auto-disabling fingerstick devices are disposable and prevent reuse through an auto-disabling feature, according to the CDC.
- “Never reuse lancets.”
- “Never use fingerstick devices for more than one person.” The CDC adds that use should be restricted to individual persons, and that the FDA recommends healthcare providers label all fingerstick devices and use them on a single patient only.
- “Dispose of used lancets at the point of use in an approved sharps container.” See sharps containers.
Compared with the FDA classes above, a lancet that is single use and has a sharps injury prevention feature is the category in 21 CFR 878.4850(a). For a wider supply list, see the diabetes clinic supply checklist.
Safe use and handling basics
Under the CDC guidance, used lancets are discarded at the point of use, and a lancet is not reused. The FDA states that a blood glucose monitoring device should not be shared with others, to reduce the risk of bloodborne pathogen transmission, and that over-the-counter blood glucose monitoring systems are for single-patient use. If a meter has to be shared, the CDC says it must be cleaned and disinfected as the manufacturer specifies; if the manufacturer does not specify how, it should not be shared. Always follow the instructions for use that come with the specific product.
Common mistakes
- Treating the lancing device as shareable because the lancet is changed. The CDC says never to use a fingerstick device for more than one person.
- Reusing a lancet. The CDC says never to reuse lancets; whether a lancet has expired is a separate question covered in do lancets expire.
- Carrying used lancets to a sharps container instead of discarding them at the point of use.
- Assuming a meter and a lancing device follow the same sharing rule. The CDC allows a meter to be shared only if the manufacturer specifies how to clean and disinfect it.
FAQ
Can lancets be reused?
No. The CDC’s instruction is “Never reuse lancets.” Single-use, auto-disabling fingerstick devices are designed to prevent reuse.
Can a lancing device be shared between people?
No. The CDC states “Never use fingerstick devices for more than one person.”
Is a lancet a regulated medical device?
Yes. Blood lancets are classified under 21 CFR 878.4850, as Class II or, for multiple use on multiple patients, Class III.
What does “lancet blood sugar test” mean?
It is the same product as a blood sugar test lancet: the sharp tip used to obtain a blood drop for a glucose test strip.
Sources
- CDC, Considerations for Blood Glucose Monitoring and Insulin Administration, 7 August 2024, checked 2026-11-03.
- eCFR, 21 CFR 878.4850 Blood lancets (Legal Information Institute copy), checked 2026-11-03.
- FDA, Blood Glucose Monitoring Devices, content current as of 11/14/2024, checked 2026-11-03.
Related supplies for monitoring and testing are listed under diagnostic, monitoring and imaging supplies.