Written and maintained by CASRAI Editorial Board
Published
On this page
A BRET assay (bioluminescence resonance energy transfer assay) detects whether two molecules are within roughly 10 nanometres of each other inside living cells. One partner is tagged with a light-emitting enzyme (a luciferase) and the other with a fluorescent acceptor. When the enzyme oxidises its substrate and the two tags are close, the energy passes to the acceptor without an outside light source, and the plate reader sees extra light at the acceptor’s wavelength. NanoBRET is the version that uses the small NanoLuc luciferase as the donor.
Definition and scope of the BRET assay
The 2019 review in Molecules defines BRET as resonance energy transfer between a light-emitting enzyme and fluorescent acceptors, and names its main advantage over biochemical methods: protein-protein interactions can be monitored without disrupting the natural environment, which detergents and membrane preparations frequently alter. A 2019 review in Frontiers in Bioengineering and Biotechnology describes BRET as a biophysical technique for monitoring proximity within live cells, and notes that it has been used extensively in pharmacological research, particularly on G protein-coupled receptors (GPCRs).
The technique grew out of a natural phenomenon. The Molecules review traces BRET to marine animals such as the sea pansy Renilla reniformis and the jellyfish Aequorea victoria, and the Frontiers review identifies the first use as a research method in 1999, when Xu and colleagues used it to study interactions of circadian clock proteins in cyanobacteria. That first system paired Renilla luciferase (Rluc) with enhanced yellow fluorescent protein (EYFP) and the substrate coelenterazine.
Scope matters, because BRET is a proximity readout and not a general-purpose binding measurement. It answers questions of the form “are these two tagged proteins, or this tagged protein and this labelled ligand, close enough to transfer energy in this cell under these conditions?” It does not by itself prove that two untagged native proteins interact, and the sections below set out what that means for interpreting a result. Related reporter chemistry that shares the luciferase side of the assay is covered in the luciferase reporter assay guide.
How a BRET assay works
The energy-transfer mechanism
According to the Frontiers review, BRET relies on dipole-dipole, non-radiative energy transfer from a luciferase energy donor to an acceptor fluorophore after the luciferase oxidises its substrate. Because transfer occurs only when donor and acceptor are within about 10 nm, attaching the two tags to proteins of interest lets proximity between the proteins be monitored. The Molecules review states the working range as under 100 Ångström, which is the same order of magnitude as conventional protein dimensions, and reports a Förster distance (R0, the separation giving 50% of maximum transfer) of about 4.4 nm for the original BRET1 system.
In the classic configuration, two proteins are expressed as fusions, one carrying the luciferase and one carrying the acceptor. After a cell-permeable substrate such as coelenterazine is added, light is read in two channels, around 480 nm for Rluc emission and around 530 nm for YFP emission. If the proteins interact, the substrate-driven energy is transferred to the YFP and extra emission appears at 530 nm.
The four factors that set signal strength
The Molecules review lists four factors that influence BRET signal intensity:
- Distance. Signal falls as the separation between the two partners increases from 10 to 100 Å.
- Spectral overlap. The donor’s emission spectrum must overlap the acceptor’s excitation spectrum.
- Relative orientation. Because transfer is dipole-dipole, the relative orientation of the pair matters.
- Donor to acceptor ratio. This is the basis of the donor saturation assay, in which a fixed amount of donor is co-expressed with increasing amounts of acceptor.
What an assay needs in practice
The Frontiers review gives three requirements for running a BRET assay: the molecules of interest must be labelled with donor and acceptor in a way that does not unduly compromise their function; the tagged molecules must be configured and localised appropriately in the experimental environment; and an instrument must be available to monitor energy transfer, most often a microplate reader that can measure live cells in real time. In reagent terms that means donor and acceptor constructs (or a labelled ligand), the luciferase substrate, cells or a suitable system to express them, and a reader that can separate the two emission channels.
The same review notes that the readout is expressed as a change in the BRET ratio, which in turn indicates proximity of the tagged proteins or small molecules.
BRET compared with FRET
Fluorescence resonance energy transfer (FRET) uses the same distance-dependent physics but starts from a fluorescent donor that must itself be excited by light. The Molecules review lists the key difference: BRET does not require extrinsic excitation by a light source, because the donor is powered by its enzymatic reaction. Both techniques need tagged fusion proteins, and the review adds that these tags may affect transport between cell compartments, post-translational modification, targeting and degradation.
What is a FRET assay?
A FRET assay measures energy transfer from an excited donor fluorophore to a nearby acceptor. Evident Scientific (Olympus) describes FRET as a process in which radiationless energy transfer occurs from an excited-state fluorophore to a nearby molecule through dipole-dipole coupling, with the two molecules positioned within a range of 1 to 10 nanometres of each other. Its page states that transfer efficiency drops with the sixth power of the separation, that the donor is excited with light matching its absorption maximum, and that the donor emission spectrum should substantially overlap the acceptor’s absorption spectrum.
That external excitation step is the practical contrast with BRET. In a BRET experiment no excitation light is used. For the microscopy side of the technique, see the FRET microscopy guide, and for the time-resolved plate-reader variant used in screening, see the HTRF assay guide.
How does a NanoBRET assay work?
A NanoBRET assay is a BRET assay whose donor is NanoLuc luciferase. In the Promega NanoBRET Protein:Protein Interaction System technical manual (TM439), the assay is described as a live-cell, proximity-based method that can be run as an endpoint or kinetic assay. The protein of one partner is fused to NanoLuc, the energy donor, and the other is fused to HaloTag, which is labelled with a fluorescent HaloTag ligand to make it the energy acceptor. Promega describes the blue-shifted NanoLuc donor and the red-shifted HaloTag acceptor as minimising spectral overlap, which improves the signal-to-background ratio.
Why NanoLuc changes the assay is explained in the Frontiers review. NanoLuc is a 19 kDa luciferase engineered from a subunit of the luciferase of the deep-sea shrimp Oplophorus gracilirostris. With its substrate furimazine it gives about 150 times the luminescence of firefly or Renilla luciferase, with a signal half-life above 2 hours, and its emission peaks near 460 nm. The review draws two consequences. First, the extra brightness allows low-abundance interactions to be monitored at lower and often more physiologically relevant expression levels. Second, the small size makes it less likely to cause function-altering steric hindrance, and allows NanoLuc to be fused to the extracellular N-terminus of a receptor for ligand-binding studies without impairing localisation at the plasma membrane.
The Molecules review adds that the NanoLuc/HaloTag pair reduces the background caused by donor signal in the acceptor channel, that NanoBRET can detect interactions in trans (between cells), and that, as of that 2019 review, the main limitation was the requirement for the synthetic substrate furimazine, which the authors described as expensive and not generically available. Reagent availability has changed over time, so a lab should confirm current supply with its own vendor.
NanoBRET formats beyond protein pairs
Per the Frontiers review, NanoBRET is also used for protein-ligand interactions, as an alternative to radioligand binding, and for target engagement at intracellular targets, where an Nluc-tagged intracellular protein is paired with a cell-permeable fluorescent dye-ligand conjugate. The Molecules review describes GPCR binding assays that tag the receptor N-terminus with NanoLuc and use BODIPY or TAMRA fluorescent ligands. The Promega manual lists a NanoBRET Positive Control and a NanoBRET PPI Control Pair (p53 and MDM2) among the system’s controls. More on the donor enzyme itself is in the NanoLuc luciferase guide.
BRET variants at a glance
BRET has branched into several systems that differ in luciferase, substrate and acceptor. The data table below compares BRET1, BRET2, eBRET, BRET3, NanoBRET and extended NanoBRET using the two review articles. Three patterns stand out from the sources:
- Spectral separation versus brightness. BRET2 shifts Rluc emission to about 395-400 nm with coelenterazine 400a, giving greater separation from the acceptor and lower background, but both reviews report weak, short-lived light output (seconds), which the Molecules review links to a need for higher expression and a higher risk of random, non-specific interactions.
- Observation time. The Frontiers table gives an approximate assay duration of about 1 hour for BRET1, over 6 hours for eBRET (EnduRen substrate), about 2 hours for NanoBRET and over 6 hours for the extended NanoBRET format. Both extended formats require a substrate pre-incubation period.
- Donor choice. BRET3 uses firefly luciferase (62 kDa according to the Molecules review) with D-luciferin, and the review reports overlap between donor and acceptor emission and sensitivity of the enzyme to ATP level, temperature and ionic strength as reasons it spread less for drug screening.
The Molecules review also notes that no standard nomenclature has ever been established for these systems, so names such as “BRET1” or “BRET2” are descriptive rather than absolute.
BRET, FRET and pull-down compared
People searching for BRET often meet pull-down and FRET in the same results, because all three are used to ask whether two proteins associate. They answer different versions of that question. Each row below is taken from the source named in the last column.
| Question | BRET | FRET | Pull-down assay | Source |
|---|---|---|---|---|
| Where does it run? | In living cells, without disrupting the native environment | Fluorescence method, applied for example in microscopy | In vitro, with bait on beads and prey in solution | Molecules 2019; Evident Scientific; J Biol Methods 2017 |
| What produces the light? | Luciferase reaction with a substrate; no extrinsic excitation | Excited donor fluorophore lit at its absorption maximum | No energy transfer; bound prey is detected on a gel | Molecules 2019; Evident Scientific; J Biol Methods 2017 |
| Distance dependence | Transfer only within about 10 nm | Fluorophores within 1 to 10 nm | Not a proximity assay; reads binding after separation of bound and unbound prey | Frontiers 2019; Evident Scientific; J Biol Methods 2017 |
| Typical output | Change in BRET ratio | Transfer efficiency | Band intensity; dissociation constant (Kd) in the quantitative form | Frontiers 2019; Evident Scientific; J Biol Methods 2017 |
| Main caution | Tags can alter protein behaviour; signal alone does not prove a specific interaction | Tags can alter protein behaviour | Non-specific binding to beads needs controls such as BSA-coupled beads | Molecules 2019; J Biol Methods 2017 |
What is the working principle of a pull-down assay?
A pull-down assay tests whether two proteins bind each other in vitro by immobilising one on beads and exposing it to the other. In the quantitative form described in the Journal of Biological Methods protocol by Lapetina and Gil-Henn (2017), one protein (the bait) is immobilised on beads while a second protein (the prey) is kept in solution. The bait concentration is held constant and the prey concentration is increased until binding saturation is reached. After incubation, the beads are precipitated to separate unbound prey from prey bound to the bait, the bound fraction is loaded on a protein gel, and the bands are analysed by densitometry to calculate a dissociation constant (Kd).
The protocol states that bait can be immobilised by affinity tags, antibody immobilisation or covalent linking to beads. It also describes the controls that keep the result honest: the beads are blocked with BSA to prevent non-specific binding, BSA-coupled beads are prepared as a control, and the prey is pre-cleared to avoid non-specific binding to bait-conjugated beads. The authors state that the in vitro pull-down shows that the interaction of two proteins is direct and not facilitated by other proteins or macromolecules.
That is the real contrast with BRET. A pull-down with purified proteins tells you about direct binding and affinity in a tube; BRET tells you about proximity in an intact cell, where other proteins and compartments are present. Each answers a question the other cannot, which is why the Molecules review recommends confirming BRET screening results with additional controls and with other methods for monitoring protein-protein interactions. An antibody-based relative of pull-down is covered in the co-immunoprecipitation guide.
What is the purpose of fluorescent proteins in these assays?
Fluorescent proteins act as genetically encoded labels: fused to a protein of interest, they let a cell make its own acceptor (in BRET) or donor and acceptor (in FRET) without chemical labelling. In BRET1 the acceptor is a yellow fluorescent protein such as eYFP or Venus. The Molecules review reports that Venus matures faster and is brighter than YFP, and notes in its Table 1 that mOrange matures slowly (half-time of about 2 hours), which is a practical drawback for an acceptor. In FRET, the Evident Scientific page uses cyan fluorescent protein as the donor in its example and lists donor-acceptor pairs with their Förster distances, for example CFP with GFP at 4.7 to 4.9 nm.
Fluorescent proteins are not the only acceptors. The sources describe synthetic dyes on HaloTag ligands (including the NCT dye ligand with emission at 635 nm), BODIPY and TAMRA ligands for binding assays, and quantum dots. For background on the fluorescent protein most people mean, see what is GFP protein.
Reading a BRET result: a checklist from the literature
Each point below comes from the caveats the sources themselves raise.
- Run a donor saturation experiment where you can. With a fixed donor and increasing acceptor, a specific interaction rises hyperbolically and plateaus when all donors are bound; a weak, linear rise indicates non-specific signal (Molecules review).
- Watch expression drift. The Molecules review notes that donor expression often decreases substantially as acceptor expression increases, which can mislead saturation curves, and that high protein levels raise the risk of random, non-specific interactions.
- Do not read a positive signal as proof. The review states that detection of a BRET signal does not necessarily reflect a specific interaction, and the absence of a signal does not mean the tagged proteins do not interact.
- Check that tags are tolerated. Tags must not unduly compromise function or localisation (Frontiers review), and larger luciferases such as Rluc are more likely to cause steric hindrance than the 19 kDa NanoLuc.
- Use a control pair and a second method. The Molecules review recommends controls with a non-related tagged protein plus an additional method for monitoring the interaction. Commercial systems supply control pairs, such as the p53 and MDM2 pair in the Promega system.
- Look for interference. Fluorescent or coloured compounds and phenol red in the medium can interfere with the signal and give false positives or false negatives (Molecules review).
- Mind detector saturation with bright donors. The Frontiers review notes that NanoLuc’s high luminescence output can saturate the detector, so a reduced detector gain or a delay before reading may be required.
- Match the luciferase to the question. Gaussia luciferase is secreted (97% of its signal is found in the supernatant in the Molecules review), so it is unsuitable for intracellular interactions, and the Frontiers review notes that NanoLuc’s blue emission is absorbed and scattered by tissue, which limits in vivo use.
Where it matters for labs and supply decisions
BRET is a bench method whose success depends on a small number of reagents and one instrument. Based on the requirements stated in the sources, a lab planning an assay should be able to list the following before starting:
- Donor and acceptor constructs, or a labelled ligand, including which terminus of each protein carries the tag, since tag position and orientation affect function and energy transfer.
- The luciferase substrate matching the donor: coelenterazine h for BRET1, coelenterazine 400a (DeepBlueC) for BRET2, EnduRen for eBRET, D-luciferin for BRET3 and furimazine for NanoBRET (Molecules and Frontiers reviews).
- An acceptor label, such as a fluorescent protein or, for the Promega PPI system, a fluorescent HaloTag ligand.
- A plate reader able to read live cells and separate the donor and acceptor channels (Frontiers review). Reagent suppliers and instrument vendors specify which readers and filter sets their systems support, so check the system’s manual.
- Controls: a positive control, a control interaction pair and non-interacting tagged proteins.
Substrates differ in how long they sustain a signal, which affects planning: the Frontiers table gives seconds for BRET2, about an hour for BRET1 and over 6 hours for the extended-duration formats, which require pre-incubation of the substrate. If an experiment needs a long kinetic read, the choice of substrate drives the choice of system.
Common misunderstandings
- “A BRET signal means the proteins interact.” It means the two tags are close enough to transfer energy under the conditions tested. Expression level, tag position and non-specific proximity all contribute, which is why saturation experiments and controls exist.
- “BRET and FRET are interchangeable.” They share the transfer physics, but only FRET needs excitation light, and the choice of donor changes background, brightness and what instruments are used.
- “NanoBRET is only for protein pairs.” The same donor is used with fluorescent ligands for receptor binding and target engagement, per the Frontiers and Molecules reviews.
- “A pull-down and a BRET assay test the same thing.” A pull-down with purified proteins reports direct binding in vitro; BRET reports proximity in cells.
- “There is one standard BRET system.” The Molecules review states that no standard nomenclature has ever been established, so a paper’s “BRET2” or “BRET3” should be read together with its stated donor, substrate and acceptor.
Frequently asked questions
What is FRET assay?
A FRET assay measures non-radiative energy transfer from an excited donor fluorophore to a nearby acceptor, which works over roughly 1 to 10 nm according to Evident Scientific. It needs external light to excite the donor, which is the main practical difference from BRET.
What is the working principle of a pull-down assay?
A bait protein is immobilised on beads and incubated with a prey protein. After the beads are separated from unbound prey, the bound fraction is analysed on a gel. The quantitative version raises the prey concentration until binding saturates and fits a dissociation constant (Lapetina and Gil-Henn, 2017).
How does a NanoBRET assay work?
One protein is fused to NanoLuc and the other to HaloTag labelled with a fluorescent ligand. When the proteins are close, energy from the furimazine-driven NanoLuc reaction transfers to the acceptor and the red-shifted emission is read in live cells as an endpoint or kinetic assay (Promega TM439).
What is the purpose of fluorescent proteins?
They are genetically encoded labels. In BRET they serve as the energy acceptor, for example eYFP or Venus, and in FRET they can serve as donor and acceptor, so cells can produce the label themselves as part of the fusion protein.
Sources
- El Khamlichi et al., Molecules 2019: Bioluminescence Resonance Energy Transfer as a Method to Study Protein-Protein Interactions: Application to G Protein Coupled Receptor Biology, checked 2026-11-20
- Frontiers in Bioengineering and Biotechnology 2019: NanoBRET: The Bright Future of Proximity-Based Assays, checked 2026-11-20
- Promega: NanoBRET Protein:Protein Interaction System Technical Manual (TM439), checked 2026-11-20
- Evident Scientific: What is Fluorescence Resonance Energy Transfer (FRET) Microscopy?, checked 2026-11-20
- Lapetina and Gil-Henn, Journal of Biological Methods 2017: A guide to simple, direct, and quantitative in vitro binding assays, checked 2026-11-20
Data: BRET system variants compared: donor, substrate, acceptor, assay duration and stated limits
Compares six BRET systems (BRET1, BRET2, eBRET, BRET3, NanoBRET, extended NanoBRET) on luciferase donor, emission peak, substrate, common acceptors, approximate assay duration and the limitation each review states. Compiled by hand from Table 1 of two open-access review articles (Molecules 2019 and Frontiers in Bioengineering and Biotechnology 2019); where the reviews differ slightly, both values are shown.
Period covered: 2019.
| BRET system | Luciferase donor | Donor emission peak (nm) | Substrate | Common acceptors (emission peak, nm) | Approximate assay duration | Stated limitation |
|---|---|---|---|---|---|---|
| BRET1 | Renilla luciferase (Rluc/Rluc8) | 475-480 | Coelenterazine h | YFP or Venus (527-530); eYFP (530) | About 1 h | Sensitive to solvent polarity, serum and pH; not suited to binding studies needing extracellular luciferase tagging |
| BRET2 | Renilla luciferase (Rluc/Rluc8) | 395-400 | Coelenterazine 400a (DeepBlueC) | GFP10 or GFP2 (about 510) | Seconds | Weak, short-lived light output; needs high expression of partners |
| eBRET | Renilla luciferase (Rluc/Rluc8) | 475-480 | EnduRen | YFP or Venus (527-530) | Over 6 h | Same as BRET1 plus substrate pre-incubation; EnduRen is expensive per the Molecules review |
| BRET3 | Firefly luciferase (FLuc, 62 kDa) | 565 | D-luciferin | DsRed (583); Cy3/Cy3.5 (570/596) | Not stated | Overlap of donor and acceptor emission; low signal-to-noise; FLuc sensitive to ATP, temperature and ionic strength |
| NanoBRET | Nanoluciferase (NanoLuc/Nluc, 19 kDa) | About 460 (462 in Molecules) | Furimazine | HaloTag ligand (618 in Molecules; 635 for HT-NCT in Frontiers); Venus (527); BODIPY; TAMRA (about 579) | About 2 h | Bright signal can saturate the detector; substrate pre-incubation; furimazine described as expensive in 2019 |
| Extended NanoBRET (eNanoBRET) | Nanoluciferase (NanoLuc/Nluc, 19 kDa) | About 460 | Endurazine (Vivazine) | HT-NCT (635); Venus (527); BODIPY; TAMRA (about 579) | Over 6 h | Detector saturation and substrate pre-incubation requirement |
Sources
- El Khamlichi et al., Molecules 2019: Bioluminescence Resonance Energy Transfer as a Method to Study Protein-Protein Interactions (accessed 2026-11-20)
- Frontiers in Bioengineering and Biotechnology 2019: NanoBRET: The Bright Future of Proximity-Based Assays (accessed 2026-11-20)
Compiled by CASRAI from the sources above. Free to reuse under CC BY 4.0 with attribution.