Written and maintained by CASRAI Editorial Board
Published
On this page
Enterolert is a defined-substrate water test from IDEXX that detects and counts enterococci, bacteria used as indicators of fecal contamination, in about 24 hours. A reagent is added to the water sample; where enterococci are present they metabolize a nutrient indicator and the sample fluoresces. In a Quanti-Tray format the fluorescent wells are counted and converted to a most probable number (MPN) per 100 mL. IDEXX states a detection limit of 1 organism per 100 mL.
Enterolert definition and scope
Enterolert is the enterococci member of IDEXX’s family of defined-substrate water tests; Colilert is the companion test for coliforms and E. coli. IDEXX describes Enterolert as detecting enterococci in drinking, bottled, recreational, wastewater, ambient and ground water, and says it is intended for water quality research and analysis by technically qualified individuals. IDEXX also states that the method is approved by the US EPA, appears in Standard Methods, and is an official ASTM method (D6503-99).
The regulatory scope is narrower than the product description, and the difference matters to anyone writing a method statement. The EPA and USGS method index (NEMI) lists the Enterolert Test Kit Procedure (revision 1999, source IDEXX) as an MPN method for ambient and compliance monitoring of fresh, drinking and saltwater. It also records that the EPA’s August 2001 Federal Register notice (66(169):45811-45829) covered enterococci in ambient surface waters only (fresh, marine and estuarine), and that applicability to other sample types has to be demonstrated by the laboratory. For where such methods sit among federal test-procedure rules, see 40 CFR Part 136.
How Enterolert works and is used in practice
The detection chemistry
The kit contains a proprietary nutrient indicator. Enterococci metabolize it, and the product of that metabolism fluoresces, which is what the analyst reads. IDEXX notes that the formulation contains no sodium azide, and that no media preparation, autoclaving or colony counting is needed. This differs from membrane filtration, where the sample is passed through a filter, the filter is incubated on a selective medium and colonies are counted.
Quantification with Quanti-Tray
For counts, IDEXX describes adding the reagent to the sample, pouring the mixture into a Quanti-Tray, sealing it in the Quanti-Tray Sealer and incubating for 24 hours at 41 °C ± 0.5 °C. Fluorescent wells are counted and the count is looked up in the MPN table supplied with the tray. The standard Quanti-Tray counts from 1 to 200 per 100 mL, and Quanti-Tray/2000 counts from 1 to 2,419 per 100 mL. NEMI records the same ranges as 1-200 MPN/100 mL for the 51-well tray and 1-2,419 MPN/100 mL for the 97-well tray, and also records a tube-based MPN option taken from Standard Methods (20th edition).
Presence/absence reading
NEMI’s method summary describes a presence/absence format in which one packet of powder is added to a 100 mL sample in a sterile, non-fluorescing vessel and incubated at 41 °C for 24 hours. The result is read at 24 hours, and before 28 hours, with a 6-watt, 365 nm ultraviolet lamp held within about 5 inches of the sample. Blue fluorescence is a positive result.
Equipment named in the method
NEMI lists the requirements as sterile pipets, sterile unbuffered dilution water, an incubator that holds 41 °C within 0.5 °C, and a 365 nm UV lamp. Reagent storage is 2-30 °C away from light; IDEXX gives a shelf life of up to 12 months from manufacture.
What an MPN result is
A Quanti-Tray result is a most probable number, a statistical estimate derived from how many wells fluoresce, not a direct count of colonies. That is why the result is read from a table and reported per 100 mL, and why the tray type sets the reportable range. A standard tray tops out at 200 per 100 mL and Quanti-Tray/2000 at 2,419 per 100 mL, so a sample expected to exceed the upper limit of the tray in use would need a different approach; NEMI’s own dilution rule for marine samples (1:10 with sterile deionized or distilled water) is the dilution step the method itself describes.
What to document when reporting an Enterolert result
The method record and the product pages together imply a short list of facts that make a result reproducible. This list is an editorial synthesis of the sources above, not a requirement quoted from any of them.
- The exact product (Enterolert or Enterolert-E) and the reference method it is reported against (ASTM D6503-99 or ISO 7899-1 as named by IDEXX).
- The tray format and its reportable range (1-200 or 1-2,419 MPN/100 mL).
- Sample temperature on receipt against the 1-4 °C handling range, and whether thiosulfate was added for a chlorinated sample.
- Incubator temperature records against the 41 °C ± 0.5 °C requirement, and the time the plate or tray was read against the 24-hour window.
- The positive and negative control strains run for the lot (ATCC 35667 and ATCC 43862) and the monthly replicate comparison.
- Any dilution made, with the diluent used.
The ASTM D6503 record
NEMI also holds a separate summary of ASTM D6503, titled Standard Test Method for Enterococci in Water Using Enterolert. It gives the current edition as approved on 10 December 1999 and published in April 2000, and describes the test as detecting enterococci such as E. faecium and E. faecalis at 1 CFU per 100 mL after 24 hours at 41 ± 0.5 °C. It lists the formats as presence/absence or quantification by 5-tube, 10-tube, 15-tube serial dilution or the Quanti-Tray system, and names drinking, source, recreational (marine and fresh) and bottled water as the matrices. It states that it is the user’s responsibility to ensure the method’s validity for waters of untested matrices, which echoes the scope caveat above. The two NEMI records also differ on sample transport: the ASTM record says to ice or refrigerate samples at 2-8 °C in transit, to avoid immersing bottles in water, and gives a maximum holding time of 6 hours, while the IDEXX procedure record says 1-4 °C. It also asks for incubator temperatures to be checked and recorded daily, and for quality control on each new lot. A laboratory should state which of the two records its procedure follows.
Enterolert variants and related methods
IDEXX sells Enterolert in more than one form. Enterolert-E is described by IDEXX as developed for the European market and as correlating with ISO 7899-1, the method used under the EU Bathing Water Directive. It uses the same 24-hour, 41 °C ± 0.5 °C incubation and is used with any multiple-tube format; with Quanti-Tray/2000 it counts 1-2,419 per 100 mL. IDEXX lists packs of 20 tests (WENTE-020) and 200 tests (WENTE-200) and states that no comparator is supplied, so a negative control is used to interpret results. The data table below compares the two IDEXX product pages with the NEMI record of the Enterolert procedure.
Enterolert measures enterococci as a group at the water-sample level. It is not an identification scheme for an isolate. Clinical and food microbiology isolates are characterized with biochemical tests such as bile esculin and the PYR test, which answer a different question. Coliform-based indicator approaches are covered in fecal coliform, and the wider workflow of sampling, holding and reporting is in bacteriological water testing.
Where Enterolert matters for labs: a quality checklist
The NEMI method summary contains the controls a laboratory needs to write into its procedure. They are collected in the table below.
| Control point | What the NEMI method record states |
|---|---|
| Sample handling | Chill samples to 1-4 °C. For chlorinated waters, add sodium thiosulfate at 0.0008% w/w. |
| Positive control culture | Enterococcus faecium ATCC 35667, run for each lot. |
| Negative control culture | Serratia marcescens ATCC 43862, run for each lot. |
| Analyst precision | Monthly replicate counts: within 5% for the same analyst and within 10% between analysts. |
| High background bacteria | Gram-positive and gram-negative bacteria above roughly 100,000 to 1,000,000 per 100 mL can interfere. |
| Marine samples | Bacillus species can interfere; a 1:10 dilution with sterile deionized or distilled water is required. |
| Incubation and reading | 41 °C within 0.5 °C; read at 24 hours and before 28 hours under 365 nm UV. |
Two points follow for a supply or quality manager. First, the reagent, the Quanti-Tray consumables, the sealer, a controlled 41 °C incubator and a 365 nm lamp are all part of the method, so a lab adopting it is committing to a set of items and not a single kit. Second, the performance statements on IDEXX’s page, such as 50% fewer false positives and 95% fewer false negatives than membrane filtration, are the manufacturer’s own claims and should be cited as such.
Common misunderstandings
Enterolert is the same as Colilert
It is not. Both use the defined-substrate approach and the Quanti-Tray format, but Colilert addresses coliforms and E. coli, while Enterolert addresses enterococci. IDEXX presents them as separate products for separate indicator organisms.
Approval for one water type covers all water types
The NEMI record states that the EPA’s 2001 notice covered enterococci in ambient surface waters and that applicability to other matrices must be demonstrated. A product page that lists drinking, bottled and wastewater among the water types it detects is describing detection, not regulatory acceptance for each of them.
Enterolert-E and Enterolert are interchangeable labels
IDEXX distinguishes the two: Enterolert-E is the product developed for the European market and correlated with ISO 7899-1, and its page states that a negative control is used for interpretation. A laboratory reporting to a particular regulator should name the exact product and reference method.
Positive means any glow
The NEMI record ties the reading to a time window (24 hours, before 28 hours), a lamp specification and a blue-fluorescence criterion, and lists interferences. A reading outside those conditions is not the method.
Sources
- IDEXX, Enterolert product page, read 2026-11-21.
- IDEXX, Enterolert-E product page, read 2026-11-21.
- National Environmental Methods Index, ASTM D6503: Enterococci in Water, method summary, read 2026-11-21.
- National Environmental Methods Index (EPA/USGS), IDEXX: Enterolert Test Kit Procedure, method summary, read 2026-11-21.
This page describes a laboratory test method for general information; it is not a substitute for the manufacturer’s current instructions or the method your regulator requires.
Data: Enterolert product pages and the NEMI method record compared: reference method, incubation, counting range and storage
Cross-walk of IDEXX's Enterolert and Enterolert-E product pages with the two NEMI (EPA/USGS) summaries of the Enterolert Test Kit Procedure, compiled on 2026-11-21 from the four pages listed as sources. Cells not stated by a source are marked as such.
Period covered: 2026-11-21.
| Record | Reference method named by the source | Incubation temperature (°C) | Incubation time (hours) | Counting range, 51-well or standard Quanti-Tray (MPN/100 mL) | Counting range, 97-well Quanti-Tray/2000 (MPN/100 mL) | Storage |
|---|---|---|---|---|---|---|
| IDEXX Enterolert page | ASTM D6503-99; US EPA approved; Standard Methods | 41 | 24 | 1-200 | 1-2,419 | 2-30 °C, away from light; shelf life up to 12 months |
| IDEXX Enterolert-E page | Correlates with ISO 7899-1 | 41 | 24 | 1-200 | 1-2,419 | 2-30 °C; shelf life up to 12 months |
| NEMI method summary 5441 (ASTM D6503, approved Dec. 10, 1999) | ASTM D6503; presence/absence or 5-, 10-, 15-tube MPN or Quanti-Tray | 41 | 24 | Not stated in this record | Not stated in this record | Not stated in this record |
| NEMI method summary 5590 (Enterolert Test Kit Procedure, rev. 1999) | MPN method; Standard Methods 20th ed.; 40 CFR 136; Fed. Reg. 66(169) 2001 | 41 | 24 | 1-200 | 1-2,419 | Not stated in this record |
Sources
- IDEXX Enterolert (accessed 2026-11-21)
- IDEXX Enterolert-E (accessed 2026-11-21)
- NEMI: ASTM D6503 Enterococci in Water (accessed 2026-11-21)
- NEMI: IDEXX Enterolert Test Kit Procedure (accessed 2026-11-21)
Compiled by CASRAI from the sources above. Free to reuse under CC BY 4.0 with attribution.







