Written and maintained by CASRAI Editorial Board
Published
On this page
The EU RoHS Directive, formally Directive 2011/65/EU, restricts the use of ten hazardous substances in electrical and electronic equipment placed on the EU market. RoHS stands for Restriction of Hazardous Substances. The European Commission states that the current directive entered into force on 21 July 2011 and that all products with an electrical or electronic component, unless specifically excluded, have to comply. For laboratories and instrument makers, the details that matter are the scope, the exclusion for research-only equipment, and the narrow exemptions for lead, cadmium and mercury in measuring instruments.
What does RoHS stand for, and what is the directive for?
RoHS stands for Restriction of Hazardous Substances, the title the European Commission uses for its page on Restriction of Hazardous Substances in Electrical and Electronic Equipment (RoHS). The directive’s Article 1 sets rules on restricting hazardous substances in electrical and electronic equipment (EEE) “with a view to contributing to the protection of human health and the environment, including the environmentally sound recovery and disposal of waste EEE”.
The Commission describes the problem it addresses: waste electrical and electronic equipment (WEEE) is one of the fastest-growing waste streams in the EU, and EEE can contain hazardous substances. EU law has restricted those substances through RoHS since 2003, while the separate WEEE Directive promotes collection and recycling of the equipment. The restricted substances are ones the Commission says can be replaced with safer alternatives: heavy metals, flame retardants and plasticisers.
Which substances does Directive 2011/65/EU restrict, and at what limits?
Article 4 requires that EEE placed on the market, including cables and spare parts, does not contain the substances listed in Annex II, above maximum concentrations measured by weight in homogeneous materials. Annex II was substituted by Commission Delegated Directive (EU) 2015/863, which is why the Commission today speaks of ten substances rather than six. The data table below lists all ten with their limits.
Two points are easy to miss. First, the limits are expressed as a maximum concentration by weight in homogeneous materials, as Article 4(2) states, not as an average over the whole finished product. Second, cadmium has a limit ten times lower (0.01%) than the other nine substances (0.1%).
What counts as electrical and electronic equipment, and what is excluded?
The definition
Article 3 defines EEE as equipment that depends on electric currents or electromagnetic fields to work properly, together with equipment for generating, transferring and measuring such currents and fields, designed for use with a voltage rating not exceeding 1,000 volts for alternating current and 1,500 volts for direct current. Equipment is “dependent” on currents or fields if it needs them to fulfil at least one intended function.
Annex I categories and the open scope
Annex I lists eleven categories. Article 2(2), which tied scope to those categories, was deleted by Directive (EU) 2017/2102, so the scope is now open: all EEE is covered unless Article 2(4) excludes it. The Commission page reflects this when it says every product with an electrical or electronic component must comply unless specifically excluded. The categories remain important because the application dates and exemption entries are keyed to them.
| Annex I category | Description in the directive |
|---|---|
| 1 | Large household appliances |
| 2 | Small household appliances |
| 3 | IT and telecommunications equipment |
| 4 | Consumer equipment |
| 5 | Lighting equipment |
| 6 | Electrical and electronic tools |
| 7 | Toys, leisure and sports equipment |
| 8 | Medical devices |
| 9 | Monitoring and control instruments, including industrial monitoring and control instruments |
| 10 | Automatic dispensers |
| 11 | Other EEE not covered by the categories above |
Article 2(4) exclusions
The directive does not apply to: equipment for security or military purposes; space equipment; equipment specifically designed as part of other excluded equipment; large-scale stationary industrial tools; large-scale fixed installations; means of transport (with a carve-out for non-type-approved electric two-wheelers); non-road mobile machinery made available exclusively for professional use; active implantable medical devices; certain professional photovoltaic panels; pipe organs; and, under point (j), “equipment specifically designed solely for the purposes of research and development only made available on a business-to-business basis”.
Point (j) is the exclusion most relevant to a research setting, and both conditions in it must hold: the equipment is designed solely for research and development, and it is made available only business-to-business. Article 3 also defines “large-scale stationary industrial tools” as including tools in an industrial manufacturing facility or a research and development facility, which is a separate route to exclusion for very large fixed equipment. The same article says the directive applies without prejudice to safety, health and chemicals legislation, in particular REACH (Regulation (EC) No 1907/2006).
What are some examples of equipment in scope?
The directive does not publish a list of named products, and a product’s status depends on the definition and exclusions above. What can be said from the text is which equipment types the directive itself recognises. Annex I names categories such as household appliances, IT equipment, lighting, tools, toys, medical devices and monitoring and control instruments. The exemption lists in Annex IV, which are limited to medical devices and monitoring and control instruments, mention specific laboratory and clinical equipment: ionising radiation detectors, X-ray tubes, ion selective electrodes including the glass of pH electrodes, electrochemical oxygen sensors, reference electrodes, helium-cadmium lasers, atomic absorption spectroscopy lamps, ultrasonic transducers, portable X-ray fluorescence instruments and superconducting circuits in MRI, SQUID, NMR and FTMS equipment (Annex IV as it stood in the consolidated text dated May 2020). An exemption only makes sense for equipment that would otherwise be restricted, so these entries indicate that such instruments fall within the directive’s scope unless Article 2(4) excludes them. That reading is an editorial interpretation, not a statement in the directive.
When did the restrictions start for each product class?
The 2011 directive did not apply to everything on the same day. Article 4(3) sets application dates for equipment that was outside the earlier Directive 2002/95/EC, and Annex II adds separate dates for the four phthalates.
| Equipment or substance group | Application date in the consolidated text |
|---|---|
| Medical devices and monitoring and control instruments | 22 July 2014 |
| In vitro diagnostic medical devices | 22 July 2016 |
| Industrial monitoring and control instruments | 22 July 2017 |
| All other EEE previously outside Directive 2002/95/EC | 22 July 2019 |
| DEHP, BBP, DBP and DIBP in medical devices (including in vitro diagnostic) and in monitoring and control instruments | 22 July 2021 |
Article 4(4) additionally exempts spare parts and cables for equipment that was placed on the market before the relevant date, so a replacement part for older equipment is not automatically caught. The Annex II text also says DEHP, BBP and DBP are not applied to toys already covered by entry 51 of REACH Annex XVII.
What are the RoHS exemptions for lead?
Article 4(6) states that the substance restriction does not apply to the applications listed in Annexes III and IV. Annex III covers exemptions for EEE in general; Annex IV covers medical devices and monitoring and control instruments. Under Article 5, the Commission adapts both annexes by delegated act, and it may include an application only if substitution is scientifically or technically impracticable, the reliability of substitutes is not ensured, or the negative environmental, health and consumer-safety impacts of substitution are likely to outweigh the benefits. When it sets the duration of an exemption, the Commission considers the availability of substitutes, socioeconomic impact and innovation.
The lead entries in the Annex III consolidated text of May 2020 include, by way of illustration:
- lead in glass of cathode ray tubes (5(a)) and in the glass of fluorescent tubes not exceeding 0.2% by weight (5(b));
- lead as an alloying element in steel for machining purposes and in galvanised steel up to 0.35% (6(a)), in aluminium up to 0.4% (6(b)) and in copper alloy up to 4% (6(c));
- lead in high melting temperature solders, meaning lead-based alloys containing 85% by weight or more lead (7(a)), and in solders for servers, storage and storage array systems and network infrastructure equipment (7(b));
- lead in glass or ceramic other than dielectric ceramic in capacitors, for example piezoelectronic devices (7(c)-I), and in dielectric ceramic in capacitors for a rated voltage of 125 V AC or 250 V DC or higher (7(c)-II).
In Annex IV, lead appears in entries relevant to laboratory and clinical instruments, including lead and cadmium in ion selective electrodes including glass of pH electrodes (1a), lead anodes in electrochemical oxygen sensors (1b), lead bearings in X-ray tubes, lead as shielding, lead in single crystal piezoelectric materials for ultrasonic transducers (14), and lead and cadmium in atomic absorption spectroscopy lamps (10). Mercury appears in reference electrodes (1d) and cadmium in helium-cadmium lasers (9).
The expiry dates attached to these entries differ by equipment category (medical devices, in vitro diagnostic devices, industrial monitoring and control instruments, other EEE) and have been amended repeatedly since the 2020 text. The Commission’s page lists the delegated directives that have amended Annexes III and IV, for example Delegated Directives (EU) 2022/1631 and 2022/1632 and, in December 2021, twelve delegated directives ending a series of mercury-in-lamp exemptions (published 24 February 2022). For that reason this page does not give current expiry dates: to know whether a particular exemption is available today, read the current consolidated text and the amending delegated directives listed by the Commission.
What is the latest update on RoHS?
The Commission’s RoHS page gives this timeline: the first RoHS rules entered into force on 27 January 2003; the current directive entered into force on 21 July 2011, with a transposition deadline of 2 January 2013; the directive was amended on 15 November 2017 by Directive (EU) 2017/2102, which adjusted the scope (Directive (EU) 2017/2102); in December 2021 delegated directives ended mercury-in-lamp exemptions; a public consultation on the review ran from 10 March to 2 June 2022; and on 7 December 2023 the Commission finalised its review and proposed a targeted amendment of the directive. The page links the review report under Article 24(2) and two supporting studies from March 2021 and March 2023. Exemptions continue to change through delegated directives, so the Commission page is the place to check for anything newer than this summary.
How does conformity work, and where does the CE mark come in?
Under Article 16, EEE bearing the CE marking is presumed to comply with the restrictions in the absence of evidence to the contrary. Equipment is also presumed compliant if tests, measurements or an assessment were carried out according to harmonised standards whose references are published in the Official Journal. The directive assigns duties to manufacturers, authorised representatives, importers and distributors (Article 3 defines each role, including “placing on the market” as the first making available of a product on the Union market), so a laboratory that imports an instrument for use in the EU should know which party carries the manufacturer’s obligations.
Common misunderstandings
- RoHS is not REACH. The directive applies without prejudice to REACH; the two address chemicals through different legal instruments. The Annex II phthalate entries even cross-refer to REACH Annex XVII.
- The limit is per homogeneous material. A product-level average is not the test the directive states.
- Exemptions do not make a product permanently compliant. Entries in Annexes III and IV are time-limited and adapted under Article 5, so an exemption used by a product must be checked against the current text.
- Research use alone does not exclude equipment. Point (j) requires equipment designed solely for research and development and made available only business-to-business.
- Medical and monitoring equipment is not outside the directive. Categories 8 and 9 are covered, with later application dates and their own Annex IV exemptions; only active implantable medical devices are excluded.
Where it matters for labs and equipment buyers
Laboratories rarely manufacture EEE, but they buy it, import it and sometimes build it. Three questions follow from the text. Is the instrument a medical device or monitoring and control instrument, whose application dates are later and which has its own exemption list? Does it rely on an Annex III or Annex IV exemption that has an expiry date? And was it made available only business-to-business and designed solely for research and development, which would place it under Article 2(4)(j)? Surface-mount and soldering processes are where lead-free manufacturing becomes concrete; see the CASRAI guides on surface mount technology and tin whiskers, and the overview of the semiconductor supply chain for the wider manufacturing context.
Frequently asked questions
What does RoHS stand for?
RoHS stands for Restriction of Hazardous Substances. The directive restricts certain hazardous substances in electrical and electronic equipment to protect human health and the environment.
What are some examples of RoHS compliant products?
The directive names no compliant products. Compliance is a property of each product’s homogeneous materials, supported by the CE marking and the conformity procedure in Article 16. The equipment types it covers are those in Annex I, from household appliances and IT equipment to medical devices and monitoring and control instruments.
What are the RoHS exemptions for lead?
Lead exemptions are listed in Annex III (general EEE) and Annex IV (medical devices and monitoring and control instruments), for example lead in high melting temperature solders and lead in glass or ceramic components. Each entry has its own conditions and expiry, and the Commission amends them by delegated directive under Article 5.
What is the latest update on RoHS?
On the Commission’s page, the most recent milestone listed is the 7 December 2023 conclusion of the review with a proposed targeted amendment of the directive. The page also lists the delegated directives that amend the exemptions.
Sources
- European Commission: Restriction of Hazardous Substances in Electrical and Electronic Equipment (RoHS), checked 2026-11-20
- legislation.gov.uk: Directive 2011/65/EU on the restriction of the use of certain hazardous substances in electrical and electronic equipment (consolidated version of 2020-05-01), checked 2026-11-20
- legislation.gov.uk: Commission Delegated Directive (EU) 2015/863 amending Annex II to Directive 2011/65/EU, checked 2026-11-20
- legislation.gov.uk: Directive (EU) 2017/2102 amending Directive 2011/65/EU, checked 2026-11-20
Data: RoHS Annex II restricted substances and maximum concentration values (Directive 2011/65/EU as amended)
Compilation of the ten substances restricted by Annex II of Directive 2011/65/EU as substituted by Delegated Directive (EU) 2015/863, with the maximum concentration by weight in homogeneous materials and notes on exemptions and application dates taken from the consolidated text and the European Commission RoHS page.
Coverage: European Union.
| Substance | Abbreviation | Maximum concentration in homogeneous materials (% by weight) | Note |
|---|---|---|---|
| Lead | Pb | 0.1 | Annex III and IV exemptions exist for specific applications |
| Mercury | Hg | 0.1 | Annex IV lists mercury in reference electrodes |
| Cadmium | Cd | 0.01 | Lowest limit of the ten; Annex IV lists cadmium in atomic absorption spectroscopy lamps |
| Hexavalent chromium | Cr(VI) | 0.1 | Listed in Annex II; limit applies per homogeneous material |
| Polybrominated biphenyls | PBB | 0.1 | Listed in Annex II; limit applies per homogeneous material |
| Polybrominated diphenyl ethers | PBDE | 0.1 | Listed in Annex II; limit applies per homogeneous material |
| Bis(2-ethylhexyl) phthalate | DEHP | 0.1 | Added by Delegated Directive 2015/863; applies to medical devices from 22 July 2021 |
| Butyl benzyl phthalate | BBP | 0.1 | Added by Delegated Directive 2015/863; applies to medical devices from 22 July 2021 |
| Dibutyl phthalate | DBP | 0.1 | Added by Delegated Directive 2015/863; applies to medical devices from 22 July 2021 |
| Diisobutyl phthalate | DIBP | 0.1 | Added by Delegated Directive 2015/863; applies to medical devices from 22 July 2021 |
Sources
- Directive 2011/65/EU consolidated version 2020-05-01 (accessed 2026-11-20)
- Commission Delegated Directive (EU) 2015/863 (accessed 2026-11-20)
- European Commission RoHS page (accessed 2026-11-20)
Compiled by CASRAI from the sources above. Free to reuse under CC BY 4.0 with attribution.