Written and maintained by CASRAI Editorial Board
Published
On this page
The FRAP assay (Ferric Reducing Antioxidant Power, originally developed as the Ferric Reducing Ability of Plasma) is a standardized, colorimetric laboratory method used to quantify the total antioxidant and reducing capacity of biological fluids, pharmaceutical extracts, foods, and beverage samples. At an acidic pH of 3.6, non-enzymatic antioxidants act as single-electron reductants, converting a colorless ferric-tripyridyltriazine [Fe(III)-TPTZ] complex into an intensely blue-colored ferrous-tripyridyltriazine [Fe(II)-TPTZ] complex that exhibits a sharp absorbance maximum at 593 nm. Because the increase in optical density at 593 nm is directly proportional to the molar concentration of electron-donating reducing agents in the reaction mixture, researchers readily quantify antioxidant activity against a ferrous sulfate standard curve or express capacity in Trolox equivalents.
In laboratory literature and protocol indices, the acronym FRAP is also widely used to describe an unrelated confocal laser microscopy method. If your research workflow involves measuring lateral molecular diffusion rates, membrane fluidity, or cytoplasmic binding kinetics through photobleaching and subsequent signal recovery, consult our dedicated technical guide to Fluorescence Recovery After Photobleaching. This current guide focuses exclusively on the redox-based colorimetric Ferric Reducing Antioxidant Power assay.
Definition, Core Mechanism, and Chemical Principle
Introduced by Iris Benzie and J. J. Strain in 1996 as a clinical tool to assess oxidative stress in blood plasma, the FRAP assay measures the collective reducing capability of small-molecule antioxidants present in a complex matrix. Unlike enzymatic antioxidant defense systems—such as superoxide dismutase, catalase, or glutathione peroxidase—which catalytically degrade reactive oxygen species, dietary and physiological non-enzymatic antioxidants neutralize oxidative radicals by direct electron donation. The FRAP assay exploits this reducing behavior through a controlled, single electron transfer (SET) redox reaction.
The assay reaction is governed by the reduction of the yellow-to-colorless ferric iron chelate, [Fe(III)(TPTZ)₂]³⁺ (where TPTZ represents 2,4,6-tri(2-pyridyl)-s-triazine), to the bis-complex [Fe(II)(TPTZ)₂]²⁺. The fundamental redox equilibrium can be expressed as:
[Fe(III)(TPTZ)₂]³⁺ + e⁻ (from antioxidant) → [Fe(II)(TPTZ)₂]²⁺ (blue complex, λmax = 593 nm)
Two physicochemical conditions dictate the validity and reproducibility of this reaction: maintaining an acidic pH of 3.6 and operating at a controlled reaction temperature (conventionally 37°C or ambient room temperature). At neutral or alkaline pH, unchelated ferric and ferrous ions spontaneously hydrolyze and precipitate as insoluble iron hydroxides and oxides, terminating the reaction and scattering light. Crucially, buffering the medium at pH 3.6 elevates the redox potential of the Fe(III)/Fe(II) couple, ensuring that virtually any antioxidant compound possessing a standard half-cell potential lower than that of the ferric-TPTZ chelate will donate an electron. Consequently, the assay operates under thermodynamic driving forces that favor rapid electron transfer from primary reducing species such as ascorbic acid, uric acid, and α-tocopherol.
The resulting [Fe(II)(TPTZ)₂]²⁺ chromophore exhibits a high molar absorptivity (approximately 22,600 M⁻¹ cm⁻¹ at 593 nm). This high extinction coefficient yields exceptional analytical sensitivity, enabling the detection of antioxidant concentrations down to sub-micromolar levels in microplate spectrophotometers and standard cuvette instruments.
Reagent Preparation and the 10:1:1 Working Formulation
A critical determinant of FRAP assay accuracy is the freshness and stoichiometric ratio of the working reagent. The classical Benzie and Strain formulation requires preparing three separate concentrated stock solutions that are combined immediately before running the assay in a 10:1:1 volumetric ratio. Consistent bench execution requires analytical grade reagents, ultrapure deionized water (resistivity ≥ 18.2 MΩ·cm), and clean polypropylene or borosilicate glassware.
- Component A: Acetate Buffer (300 mM, pH 3.6). Dissolve 3.10 g of sodium acetate trihydrate (CH₃COONa·3H₂O) in approximately 800 mL of deionized water. Add 16.0 mL of glacial acetic acid (CH₃COOH). Verify and adjust the pH to precisely 3.60 ± 0.02 using a calibrated pH meter (using concentrated HCl or 1 M NaOH only if necessary), then dilute with deionized water to a final volume of 1.00 L. This buffer provides the ionic strength and buffering capacity required to maintain an invariant acidic reaction environment when complex samples are introduced; see our practical review of buffer solution principles for background on maintaining pH stability during analytical titrations.
- Component B: TPTZ Solution (10 mM). Dissolve 0.0312 g of 2,4,6-tripyridyl-s-triazine in 10.0 mL of 40 mM hydrochloric acid (HCl). Because TPTZ dissolves sluggishly at room temperature, gently warm the vial in a 50°C water bath with intermittent vortexing until the powder completely dissolves. TPTZ is sensitive to photochemical oxidation; store this solution wrapped in aluminum foil at 4°C, and discard if any discoloration occurs.
- Component C: Ferric Chloride Solution (20 mM). Dissolve 0.0541 g of ferric chloride hexahydrate (FeCl₃·6H₂O) in 10.0 mL of deionized water. Prepare this solution fresh on the day of experimentation, as aqueous ferric chloride solutions slowly form colloidal oxy-hydroxide precipitates over extended storage.
Assembling the Working FRAP Reagent: Mix Component A, Component B, and Component C in a 10:1:1 volumetric ratio (for example, 25.0 mL of acetate buffer, 2.5 mL of TPTZ solution, and 2.5 mL of ferric chloride solution). Pre-warm the assembled working reagent to 37°C in an incubator or water bath prior to dispensing. The working solution should exhibit a pale brownish-straw appearance. Inspect the reagent blank: if the initial absorbance at 593 nm against air or water exceeds 0.080 OD units, the working solution has suffered premature reduction or iron contamination and must be discarded and remade.
Step-by-Step Bench Protocol and Standard Curve Setup
The FRAP assay can be conducted either in standard 1.0 cm pathlength spectrophotometer cuvettes or in clear, flat-bottom 96-well microplates for high-throughput screening. The microplate format dramatically conserves reagent volume and allows simultaneous measurement of multiple standards, controls, and technical replicates.
1. Standard Curve Preparation: Prepare a primary stock solution of 2.0 mM ferrous sulfate heptahydrate (FeSO₄·7H₂O, molecular weight 278.02 g/mol) by dissolving 0.0556 g in 100.0 mL of deionized water or 300 mM acetate buffer. Serial dilutions are constructed to span a typical working range of 0 to 1,000 μM Fe(II):
- Standard 0 (Reagent Blank): 0 μM Fe(II) (pure assay diluent)
- Standard 1: 100 μM Fe(II)
- Standard 2: 250 μM Fe(II)
- Standard 3: 500 μM Fe(II)
- Standard 4: 750 μM Fe(II)
- Standard 5: 1,000 μM Fe(II)
Alternatively, for studies reporting Trolox Equivalent Antioxidant Capacity (TEAC), a parallel standard curve is constructed using 6-hydroxy-2,5,7,8-tetramethylchroman-2-carboxylic acid (Trolox) dissolved in ethanol or methanol over concentrations ranging from 0 to 500 μM.
2. Sample Extraction and Preparation: Biological fluids (plasma, serum, saliva) can generally be analyzed after mild dilution in deionized water or assay buffer (typically 1:5 to 1:20 dilution). Plant leaves, botanical supplements, and food products require solvent extraction (such as acidified 80% aqueous methanol or ethanol). Solid homogenates must be centrifuged at 12,000 × g for 10 minutes at 4°C to pellet insoluble particulates, yielding an optically clear supernatant.
3. Microplate Pipetting Scheme: Dispense 10.0 μL of each standard, unknown sample, or sample blank into triplicate wells of a clear 96-well plate. Add 190.0 μL of pre-warmed (37°C) working FRAP reagent to each well using a calibrated multi-channel pipette, bringing the total reaction volume to 200.0 μL. For strongly colored extracts (such as red wine, berry juices, or beet extracts), prepare corresponding sample blanks containing 10.0 μL of sample combined with 190.0 μL of 300 mM acetate buffer without TPTZ or iron to correct for intrinsic background absorbance.
4. Incubation and Spectrophotometric Detection: Gently agitate the plate on an orbital shaker for 15 seconds to ensure homogeneous mixing. Incubate the plate at 37°C in the dark. For routine screening of clinical plasma or simple reducing compounds, record the absorbance at 593 nm exactly 4 minutes after reagent addition. For botanical extracts rich in complex flavonoids and polyphenols, continue the incubation and record absorbance at 15 and 30 minutes, as extended incubation is required to monitor slow electron-donating phenolic groups. Ensure your instrument parameters distinguish properly between absorbance and optical density measurements, accounting for pathlength corrections when comparing 96-well microplate data against standard 1-cm pathlength cuvettes.
Calculations, Standard Curve Fitting, and Worked Example
Quantifying antioxidant capacity requires constructing a linear calibration curve from the standard series and applying regression mathematics to correct for dilution and background absorbance. The net absorbance change for each standard and sample is determined by subtracting the reagent blank absorbance:
ΔA = A_sample − A_blank
For pigmented samples with significant native color at 593 nm, the corrected absorbance is refined by subtracting both the reagent blank and the intrinsic sample blank:
ΔA_corrected = A_sample − A_reagent_blank − A_sample_blank
A linear regression line is plotted with standard concentration (in μM) on the x-axis and corrected absorbance (ΔA) on the y-axis, yielding the classic equation y = mx + c, where m represents the calibration slope (sensitivity, in OD·μM⁻¹) and c is the y-intercept. The equivalent concentration in the diluted well is calculated as:
C_well (μM) = (ΔA_corrected − c) / m
To establish the concentration in the original undiluted liquid sample or biological fluid, multiply by the dilution factor (DF):
C_sample (μM Fe(II) equivalents) = C_well × DF
When analyzing solid matrices (such as dried herbs, powders, or agricultural produce), normalize the total antioxidant capacity per unit of sample dry mass:
Antioxidant Capacity (μmol Fe(II) / g dry weight) = (C_sample × V_extract) / m_dry
where C_sample is expressed in μmol/L, V_extract is the total solvent extraction volume in liters (L), and m_dry is the dry mass of extracted sample in grams (g). This rigorous regression and unit conversion workflow mirrors the calibration models utilized in Bradford protein assay standard curve calculations.
Worked Example Walkthrough: Consider an analytical chemist analyzing an aqueous extract of green tea (Camellia sinensis). A 1.000 g sample of dried tea leaves was extracted in 50.0 mL (0.0500 L) of 80% aqueous methanol. Because the raw extract produced an off-scale optical density, the analytical solution was diluted 1:50 in deionized water (dilution factor DF = 50).
- Standard curve regression equation: y = 0.00115x + 0.0120 (where x is Fe(II) concentration in μM, R² = 0.9992)
- Reagent blank absorbance (A_reagent_blank): 0.045 OD
- Sample well raw absorbance (A_sample): 0.655 OD
- Sample blank absorbance (A_sample_blank, tea extract + buffer without TPTZ): 0.018 OD
- Net corrected absorbance: ΔA_corrected = 0.655 − 0.045 − 0.018 = 0.592 OD
- Calculating well concentration: C_well = (0.592 − 0.0120) / 0.00115 = 504.35 μM Fe(II) equivalents
- Applying dilution factor (DF = 50): C_extract = 504.35 μM × 50 = 25,217.4 μM = 25.22 mM Fe(II) equivalents
- Normalizing to dry leaf mass: Capacity = (25,217.4 μmol/L × 0.0500 L) / 1.000 g = 1,260.9 μmol Fe(II) / g dry weight
This resulting antioxidant capacity aligns with benchmark published ranges established by Benzie and Szeto (1999) for commercial unfermented green teas (typically 272 to 1,144 μmol/g dry mass), verifying proper bench execution and dilution control.
Method Comparison: FRAP vs DPPH, ABTS, ORAC, and CUPRAC
Antioxidant activity cannot be fully characterized by a single analytical assay because free-radical scavenging in biological and food systems involves distinct reaction mechanisms, steric accessibilities, and phase partitioning. The analytical chemistry community classifies antioxidant assays into two fundamental categories: Single Electron Transfer (SET) assays and Hydrogen Atom Transfer (HAT) assays. Selecting an appropriate assay or designing a multi-method screening panel requires understanding the technical divergence summarized in the comparison table below.
| Assay Method | Chemical Mechanism | Reaction Medium & pH | Chromogenic Probe / Oxidant | Detection λ (nm) | Key Analytes Measured | Primary Analytical Limitation |
|---|---|---|---|---|---|---|
| FRAP | Single Electron Transfer (SET) | Aqueous acetate buffer, pH 3.6 | [Fe(III)(TPTZ)₂]³⁺ complex | 593 | Ascorbic acid, uric acid, polyphenols | Misses thiol antioxidants (glutathione); non-physiological acidic pH |
| DPPH | Mixed SET and HAT | Organic (methanol or ethanol), neutral | 2,2-diphenyl-1-picrylhydrazyl radical | 517 | Lipophilic phenolics, small tocopherols | Steric hindrance blocks large polyphenols; insolubility in pure aqueous buffers |
| ABTS / TEAC | Single Electron Transfer (SET) | Aqueous or organic, pH 7.4 | ABTS•⁺ radical cation | 734 | Hydrophilic and lipophilic antioxidants | Pre-generation of radical required; radical is synthetic and non-physiological |
| ORAC | Hydrogen Atom Transfer (HAT) | Aqueous phosphate buffer, pH 7.4, 37°C | Peroxyl radical (AAPH) + Fluorescein | Ex 485 / Em 520 | Chain-breaking radical scavengers | Requires fluorescence microplate reader; slow kinetics; sensitive to thermal drift |
| CUPRAC | Single Electron Transfer (SET) | Aqueous ammonium acetate, pH 7.0 | [Cu(II)(neocuproine)₂]²⁺ complex | 450 | Polyphenols, ascorbic acid, thiols (GSH) | Slow reaction kinetics for certain glycosylated flavonoids; copper complex stability |
As demonstrated across comparative bioanalytical studies, the primary operational advantage of the FRAP assay is its experimental simplicity, rapid reaction rate, low consumable cost, and absence of unstable synthetic free radicals. However, because it operates via an electron-transfer mechanism under unphysiological acidic conditions (pH 3.6), it cannot replicate the competitive hydrogen atom transfer kinetics measured by the ORAC assay. Furthermore, while the FRAP reagent responds robustly to phenolic acids and vitamins, it exhibits negligible reactivity toward endogenous sulfur-containing antioxidants. Understanding these operational differences is as critical to assay selection as choosing between colorimetric reagents when assessing protein assays in biochemistry.
Common Interferences, Reaction Kinetics, and Troubleshooting
Achieving reproducible data in the FRAP assay demands careful management of reaction kinetics, spectral interferences, and chemical matrix effects. Methodologists commonly encounter three primary categories of analytical deviation:
1. Differential Reaction Kinetics (Fast vs. Slow Reducers): A fundamental limitation of the standard 4-minute incubation protocol is that different antioxidant classes reduce ferric iron at widely varying rates. Simple reducing compounds such as ascorbic acid, uric acid, and α-tocopherol complete their electron donation within 1 to 4 minutes at 37°C, reaching a stable spectrophotometric plateau. In contrast, complex dietary polyphenols—particularly flavonoids with B-ring catechol structures (quercetin, catechin, rutin) and hydrolyzable tannins (tannic acid)—exhibit prolonged reduction kinetics that continue to generate blue Fe(II)-TPTZ complex for 30 to 60 minutes. Truncating measurements strictly at 4 minutes underestimates the antioxidant power of polyphenol-rich plant samples by 20% to 50%. Best practice requires logging absorbance kinetically or standardizing endpoint readings at 30 minutes for botanical matrices, as established by Pulido and colleagues (2000).
2. Inability to Detect Thiol Antioxidants: One of the most pronounced chemical blind spots of the FRAP assay is its failure to measure thiol (-SH) antioxidants, most notably reduced glutathione (GSH) and protein-bound cysteine residues such as albumin. Under the acidic conditions (pH 3.6) of the FRAP reagent, the redox potential of the thiol/disulfide couple is unfavorable, rendering glutathione virtually unreactive over standard measurement windows. In human blood plasma, where albumin and glutathione represent major physiological antioxidant defenses, the FRAP value is primarily driven by uric acid (responsible for ~60% of total plasma FRAP), ascorbic acid (~15%), and α-tocopherol (~5%). If a research objective focuses on cellular glutathione status, researchers must employ alternative assays such as CUPRAC or enzymatic DTNB recycling.
3. Matrix Pigmentation and Turbidity: Crude biological and agricultural extracts frequently contain endogenous pigments (anthocyanins, carotenoids, chlorophylls) that absorb light across the 500–620 nm region. If uncorrected, native sample absorbance creates substantial positive bias. Analysts must run parallel sample color blanks containing sample and acetate buffer without ferric chloride or TPTZ. Furthermore, insoluble proteins or lipids can precipitate upon encountering the low-pH reaction mixture, inducing light scattering. If sample wells display turbidity, pre-clear samples by microcentrifugation or ultrafiltration (10 kDa molecular weight cut-off) before adding the FRAP reagent.
4. Chemical and Chelating Interferences: Samples extracted using lysis buffers containing reducing agents such as dithiothreitol (DTT) or 2-mercaptoethanol will generate overwhelming false-positive color development, as these chemicals directly reduce ferric iron. Similarly, excessive concentrations of strong metal chelators (such as EDTA exceeding 10 μM) sequester iron from the TPTZ ligand, depressing color development and causing negative analytical bias. When preparing biological specimens, heparin or citrate is preferred over EDTA as an anticoagulant.
Laboratory Operations and Quality Control Decisions
Implementing the FRAP assay within compliant quality control environments—such as testing laboratories producing a Certificate of Analysis (COA) for raw botanical ingredients or dietary supplements—requires adherence to strict validation acceptance criteria. Routine bench protocols must incorporate three levels of analytical control:
- Precision Limits: Intra-assay precision across triplicate wells should yield a coefficient of variation (%CV) below 2.0%. Inter-assay precision across separate analytical runs or multiple plate batches should not exceed 5.0% CV.
- Linearity and Calibration Range: Standard curves constructed with FeSO₄·7H₂O must achieve a correlation coefficient (R²) ≥ 0.995 across the working range (typically 50 to 1,000 μM). Any unknown sample whose absorbance exceeds the highest calibration standard must be re-tested at an increased dilution; extrapolating beyond the linear range introduces severe non-linear bias due to reagent depletion.
- Limits of Detection (LOD) and Quantitation (LOQ): Under standard microplate protocols, the empirical limit of detection (calculated as 3.3 × SD_blank / slope) is approximately 10 to 20 μM Fe(II) equivalents, with a practical quantitation limit of 50 μM Fe(II) equivalents.
- Positive Reference Controls: Each microplate run should incorporate a known concentration of Trolox or ascorbic acid (such as 250 μM) as an active positive control. If the recovered concentration deviates by more than ±7% from the theoretical target, the entire batch must be invalidated and re-run.
The data table below compares the stoichiometric ferric-reducing factors and reaction kinetics across ten reference antioxidants and plasma components.
Frequently asked questions
What does FRAP stand for in laboratory testing?
FRAP stands for Ferric Reducing Antioxidant Power (originally named the Ferric Reducing Ability of Plasma in the foundational 1996 publication by Benzie and Strain). It refers to a colorimetric assay measuring the capacity of antioxidants to reduce ferric iron [Fe(III)] to ferrous iron [Fe(II)] under acidic conditions.
Why is the FRAP assay performed at an acidic pH of 3.6?
The assay requires a low pH (3.6) for two essential reasons: first, to maintain iron solubility and prevent ferric and ferrous ions from precipitating as insoluble iron hydroxides, and second, to shift the redox potential of the ferric-tripyridyltriazine complex, driving spontaneous electron transfer from reducing antioxidant compounds.
How does the FRAP assay differ from the ORAC and DPPH assays?
FRAP operates purely via a Single Electron Transfer (SET) mechanism using an inorganic metal complex at pH 3.6. In contrast, DPPH measures the reduction of an organic nitrogen radical in alcohol solvents, while ORAC measures competitive Hydrogen Atom Transfer (HAT) against physiological peroxyl radicals at physiological pH (7.4) and 37°C.
Can the FRAP assay measure glutathione and protein thiol antioxidants?
No. Under the acidic pH (3.6) conditions of the FRAP reagent, thiol (-SH) groups such as reduced glutathione (GSH) and protein cysteine residues exhibit an unfavorable redox potential and react too sluggishly to reduce ferric iron. FRAP is therefore insensitive to thiol-based antioxidant defenses.
What is the difference between expressing FRAP results in Fe(II) equivalents versus Trolox equivalents?
Expressing results in Fe(II) equivalents directly reflects the stoichiometry of iron reduction using a ferrous sulfate calibration curve (1 mole of standard reduces 1 mole of Fe(III)). Trolox equivalents (TEAC) normalize the data against a synthetic vitamin E analogue, enabling direct comparability with other antioxidant assays like ABTS and DPPH.
Why do some antioxidants require 30 minutes or longer to complete the FRAP reaction?
While simple compounds like ascorbic acid and uric acid donate electrons within 1 to 4 minutes, complex polyphenols, tannins, and flavonoids with sterically hindered hydroxyl groups exhibit slow, multi-stage electron transfer kinetics. Terminating measurements at 4 minutes underestimates total antioxidant capacity in plant and food extracts.
Sources
- Benzie, I. F. F., & Strain, J. J. (1996). The ferric reducing ability of plasma (FRAP) as a measure of ‘antioxidant power’: the FRAP assay. Analytical Biochemistry, 239(1), 70-76. https://doi.org/10.1006/abio.1996.0292 (Checked 2026-11-15)
- Pulido, R., Bravo, L., & Saura-Calixto, F. (2000). Antioxidant activity of dietary polyphenols as determined by a modified ferric reducing/antioxidant power assay. Journal of Agricultural and Food Chemistry, 48(8), 3396–3402. https://doi.org/10.1021/jf9913458 (Checked 2026-11-15)
- Abcam (2020). FRAP Assay Kit (ab234626) Protocol Booklet. https://www.abcam.com/ps/products/234/ab234626/documents/ab234626-FRAP-Assay-Kit-protocol-booklet-v3c.pdf (Checked 2026-11-15)
- Sigma-Aldrich / MilliporeSigma (2021). Ferric Reducing Antioxidant Power (FRAP) Assay Kit Technical Bulletin (MAK369). https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/product/documents/340/314/mak369bul.pdf (Checked 2026-11-15)
- Prior, R. L., Wu, X., & Schaich, K. (2005). Standardized methods for the determination of antioxidant capacity and phenolics in foods and dietary supplements. Journal of Agricultural and Food Chemistry, 53(10), 4290–4302. https://doi.org/10.1021/jf0502698 (Checked 2026-11-15)
- Benzie, I. F. F., & Szeto, Y. T. (1999). Total antioxidant capacity of teas by the ferric reducing/antioxidant power assay. Journal of Agricultural and Food Chemistry, 47(2), 633–636. https://doi.org/10.1021/jf9807768 (Checked 2026-11-15)
Data: FRAP Assay Stoichiometric Reducing Factors and Reaction Kinetics
Comparative benchmark of stoichiometric iron-reducing factors, kinetic plateau times, and matrix roles across ten antioxidant standards and physiological compounds in the FRAP assay, compiled from Benzie & Strain (1996), Pulido et al. (2000), and Prior et al. (2005).
Period covered: 1996/2005. Coverage: Global.
| Compound | Chemical Class | Stoichiometric Factor (mol Fe(II) / mol compound) | Time to Plateau (min) | Biological or Matrix Role |
|---|---|---|---|---|
| Ascorbic acid | Water-soluble vitamin | 2 | 4 | Primary water-soluble antioxidant in plasma and citrus |
| Uric acid | Purine metabolite | 2 | 4 | Major endogenous small-molecule reducing agent in human plasma |
| Alpha-tocopherol | Lipid-soluble vitamin | 2 | 4 | Membrane-bound peroxyl radical scavenger in lipoproteins |
| Trolox | Synthetic chroman derivative | 2 | 4 | Hydrophilic calibration standard for TEAC comparisons |
| Bilirubin | Tetrapyrrole bile pigment | 4 | 10 | Endogenous heme degradation product with potent reducing activity |
| Albumin | Plasma protein | 0.1 | 60 | Abundant circulating protein with shielded and unreactive thiols at pH 3.6 |
| Quercetin | Flavonol (flavonoid) | 4.4 | 30 | Dietary plant polyphenol with multi-stage electron donation |
| Gallic acid | Hydroxybenzoic acid | 6 | 30 | Trihydroxy phenolic acid found in tea, oak bark, and gallnuts |
| Caffeic acid | Hydroxycinnamic acid | 3.8 | 30 | Widespread plant cinnamic acid derivative with ortho-hydroxyls |
| Tannic acid | Hydrolyzable tannin | 12 | 30 | High-molecular-weight polyphenol with extensive ferric reducing power |
Sources
- Benzie & Strain (1996) Analytical Biochemistry (accessed 2026-11-15)
- Pulido et al. (2000) Journal of Agricultural and Food Chemistry (accessed 2026-11-15)
- Prior et al. (2005) Journal of Agricultural and Food Chemistry (accessed 2026-11-15)
Compiled by CASRAI from the sources above. Free to reuse under CC BY 4.0 with attribution.