High Power Objective on a Microscope: Function and Use

What the high power objective does, how NA and working distance change at 40x, and how to use it after low power.

Written and maintained by CASRAI Editorial Board

Published

On this page

The high power objective is the microscope lens, typically the 40x objective, that gives the highest dry magnification and the finest resolving power on a standard compound microscope, so that cell-level detail the lower-power lenses cannot separate becomes visible. The price is a much smaller field of view and a much shorter working distance, which is why it is used after the specimen has been found and centred with a lower-power objective.

What the high power objective is

A compound microscope carries several objectives on a rotating nosepiece. Teaching and routine laboratory instruments commonly fit 4x, 10x, 40x and 100x lenses (Garrett College library guide, read 2026-11-17). In everyday lab language the 4x is the scanning objective, the 10x is the low power objective, the 40x is the high power objective and the 100x is the oil immersion objective. Those labels are conventions of use, not engraved specifications: what is engraved on every objective is its magnification and its numerical aperture (NA), plus marks for tube length, coverslip thickness, correction class and immersion type (Evident Scientific, objectives page, read 2026-11-17).

Total magnification is the objective magnification multiplied by the eyepiece (ocular) magnification. A 10x ocular used with a 40x objective gives 400x (Garrett College library guide). For the light path that surrounds the objective, see compound microscope optics, and for the eyepiece side see what an ocular lens does.

What the high power objective does

The objective forms the primary image, so everything the rest of the microscope can show is limited by it. A high power objective does three things that a low power objective does not.

  • It shows finer detail. Higher magnification is paired with higher NA. NA is defined as n × sin(α), where n is the refractive index of the medium between the front lens and the specimen and α is half the angular aperture of the light cone the lens collects (Nikon MicroscopyU, numerical aperture, read 2026-11-17). A larger NA means the lens gathers a wider cone of light and can resolve finer structure.
  • It narrows the view. Higher magnification means more detail but a smaller field of view, while a low power objective shows a wider area of the slide (Garrett College library guide). That is the reason you cannot search a slide at high power.
  • It sits very close to the specimen. Working distance, the clearance between the closest surface of the cover glass and the objective front lens, generally decreases as magnification and NA rise (Evident Scientific, objectives page).

High power versus lower power objectives

The lower power objectives (the scanning 4x and the low power 10x) exist to locate and survey. The high power objective exists to examine something already located. The table below summarises the division of labour; it is an editorial summary of the library-guide and manufacturer statements cited in this section.

Objective (common label) Typical magnification Role in the workflow Field of view and detail
Scanning 4x First look: find the specimen and the area of interest Widest area, least detail
Low power 10x Survey and centre the structure to be examined Wide area, moderate detail
High power 40x Examine cell-level detail in the centred field Small area, much finer detail
Oil immersion 100x Highest resolution; used with immersion oil between lens and cover glass Smallest area, highest detail

Lower power objective function

The lower power objective is where every observation starts. The Garrett College guide instructs users to begin with the lowest-power objective and to use the coarse focus knob only at low power. At low power the large field of view means the specimen is easy to find, and the long working distance means there is little risk of the lens touching the slide. Evident Scientific’s table lists a 4x achromat with a working distance of 30.00 mm and a 10x achromat with 6.10 mm, against 0.65 mm for a 40x achromat.

How the objective is built and marked

The engraved markings tell you what you are holding (Evident Scientific, objectives page):

  • Magnification, written as 10x, 20x, 40x and so on.
  • Tube length, usually 160 mm or the infinity symbol, the design tube length.
  • Coverslip thickness, usually 0.17 mm, the thickness the designer assumed when correcting spherical aberration.
  • Numerical aperture, always engraved, from about 0.04 for low-power objectives to 1.3 or 1.4 for high-power oil apochromats.
  • Immersion type: oil objectives are marked OIL, OEL or HI; with none of these marks the objective is for dry use.
  • Correction class: terms such as apochromat, apo, plan or FL/fluor indicate higher correction; objectives with no such marking are usually achromats.

The manufacturer’s own specification for a real 40x lens shows how these numbers sit together. The Zeiss Plan-Apochromat 40x/1.3 Oil DIC M27 lists a free working distance of 0.21 mm, a coverglass thickness of 0.17 mm, a parfocal length of 45.06 mm and a field-of-view number of 25 (Zeiss Micro-Shop product page, read 2026-11-17). With a free working distance of 0.21 mm, high power focusing is done with the fine knob, as the Garrett College guide directs.

What numerical aperture a 40x objective actually delivers

Two objectives both labelled 40x can differ considerably. Nikon’s reference table gives the NA by correction class: a 40x Plan Achromat is 0.65, a 40x Plan Fluorite is 0.75 and a 40x Plan Apochromat is 0.95. Dry objectives rarely exceed an NA of about 0.95, and immersion media (water, glycerin, immersion oil) raise it; most oil immersion objectives have a maximum NA of 1.4 (Nikon MicroscopyU). The data table below this guide sets NA and working distance side by side for objectives of each class, compiled from the Evident Scientific and Zeiss pages, so you can see that the sharper 40x lens is also the one with the shorter working distance (0.14 mm for the 40x Plan Apochromat against 0.57 mm for the 40x Plan Achromat in Evident’s table).

For how to choose between NA, correction class and immersion for a given project, see microscope objective selection; this page deals only with the role of the high power lens in the routine workflow. The resolution that a given NA sets is covered in the optical microscopy resolution limit.

Using the high power objective safely

These are general handling points from the sources read, not a substitute for your instrument’s manual.

  1. Start low. Begin with the lowest-power objective and use the coarse focus knob only at low power (Garrett College library guide).
  2. Centre before you step up. At high power the field of view is much smaller, so the structure you want must be in the middle of the field at low power first.
  3. Rely on parfocal design. A matched objective set is described as parfocal, which Evident Scientific calls a useful convenience and safety feature: switching objectives needs little use of the fine focus knob because the images are projected to roughly the same plane.
  4. Refine with the fine knob only. The Garrett College guide directs the fine focus knob for higher power. With a working distance of a fraction of a millimetre, the coarse knob is where a slide or lens can be damaged.
  5. Use the coverslip the objective was designed for. The objective is corrected for a specified coverslip thickness, usually 0.17 mm (Evident Scientific; Zeiss), so a correct coverslip matters more at high power. For slide preparation, see microscope slide preparation.
  6. Do not use immersion oil on a dry objective. Oil is for objectives marked OIL, OEL or HI. A 40x without those marks is a dry lens.

Common mistakes with the high power objective

  • Searching at high power. Because the field of view is small and the image is hard to find, locate the specimen at low power first (Garrett College library guide).
  • Using the coarse knob at high power. This is the quickest way to bring a short working distance lens into the slide.
  • Assuming every 40x is the same. The NA for a 40x lens ranges from 0.65 to 0.95 for dry classes and reaches 1.30 for an oil 40x (Nikon MicroscopyU), and the working distances differ accordingly.
  • Quoting total magnification as resolution. Magnification multiplies the image size; the fine detail visible depends on the objective’s NA. The 400x of a 10x eyepiece with a 40x objective is only as detailed as the objective’s NA allows.
  • Ignoring the engraved markings. The coverslip thickness, immersion type and correction class are printed on the barrel for a reason (Evident Scientific).

Who uses the high power objective

It is used by anyone who examines stained or prepared specimens on a compound microscope: students learning the instrument, laboratory staff who check cell morphology and prepared slides, and researchers who need a dry objective with more resolving power than the 10x or 20x. Those who need more resolution than a dry lens can provide move to the oil immersion objective.

Sources

Data: Numerical aperture and working distance of 4x to 100x microscope objectives by correction class

Numerical aperture and working distance for dry and oil objectives from 4x to 100x, grouped by correction class (Plan Achromat, Plan Fluorite, Plan Apochromat), compiled from Evident Scientific's objective specification table and the Zeiss Micro-Shop listing for a 40x/1.3 oil objective. Shows that higher NA comes with shorter working distance.

Numerical aperture and working distance of 4x to 100x microscope objectives by correction class
ObjectiveNumerical apertureWorking distance (mm)Source
Plan Achromat 4x0.130Evident Scientific
Plan Achromat 10x0.2510.5Evident Scientific
Plan Achromat 20x0.41.3Evident Scientific
Plan Achromat 40x0.650.57Evident Scientific
Plan Fluorite 4x0.1317.1Evident Scientific
Plan Fluorite 10x0.316Evident Scientific
Plan Fluorite 20x0.52.1Evident Scientific
Plan Fluorite 40x0.750.72Evident Scientific
Plan Apochromat 4x0.215.7Evident Scientific
Plan Apochromat 10x0.454Evident Scientific
Plan Apochromat 20x0.751Evident Scientific
Plan Apochromat 40x0.950.14Evident Scientific
Plan Fluorite 40x oil1.30.2Evident Scientific
Plan Achromat 100x oil1.250.17Evident Scientific
Plan Apochromat 100x oil1.40.13Evident Scientific
Plan-Apochromat 40x/1.3 Oil DIC M271.30.21Zeiss Micro-Shop

Sources

Compiled by CASRAI from the sources above. Free to reuse under CC BY 4.0 with attribution.

Follow CASRAI

Research-administration guidance, standards updates and independent tool reviews.

Ask CASRAI · full access

Ask about High Power Objective on a Microscope: Function and Use

Full access: large monthly usage, up to 10 source passages behind each answer, and MCP and API access for Claude Code, Codex and other CLIs. Cancel any time.

An AI assistant for research: funder rules, compliance, methods and publishing. It links the sources behind its answers and labels answers that come from a web search.

Answers draw on CASRAI's guides and dictionary plus the federal and funder documents we index: Federal Register, Grants.gov, Regulations.gov and UKRI.

Works on this site and inside Claude, Cursor and the AI tools you already use.

Everything CASRAI publishes — this page, the dictionary, the guides and the news — stays open to read, with no account and no card.

Referenced across the research world

University of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logoUniversity of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logo
  • University of Cambridge logo
  • Columbia University logo
  • Crossref logo
  • University of Edinburgh logo
  • Harvard University logo
  • University of Oxford logo
  • Princeton University logo
  • Stanford School of Medicine logo
  • University College London logo
  • ORCID logo

View CASRAI adoption →