Skip to main content
v2026.11,986 entries · CC-BY 4.0

IEC 61215: PV Module Design Qualification Standard Explained

IEC 61215 sets design qualification tests for terrestrial PV modules; this guide maps the series, the MQT tests and how it differs from IEC 61730.

Written and maintained by CASRAI Editorial Board

Published

On this page

IEC 61215 is the International Electrotechnical Commission standard series for the design qualification and type approval of terrestrial photovoltaic (PV) modules. It defines a sequence of laboratory tests used to judge whether a module design is suitable for long-term operation in open-air climates. It is a test standard for module designs, not a prediction of how many years a module will last, and it is not the same document as IEC 61730, which covers the safety construction and testing of PV modules.

What IEC 61215 covers

The first part of the series, IEC 61215-1:2021 (edition 2.0, published 2021-02-23), is titled “Terrestrial photovoltaic (PV) modules – Design qualification and type approval – Part 1: Test requirements”. The IEC webstore states that it “lays down requirements for the design qualification of terrestrial photovoltaic modules” suitable for long-term operation in open-air climates. It replaces the first edition published in 2016.

Two phrases in that scope matter for anyone reading a test report. The first is “design qualification”: the tests are run on samples of a module design, so a pass speaks about the design and its materials, not about every module that later leaves a factory. The second is the sentence “Test results are not construed as a quantitative prediction of module lifetime.” The scope text of Part 2 adds that the useful service life of a qualified module depends on its design, its environment and the conditions under which it is operated.

The standard is intended to apply to all terrestrial flat plate module materials, such as crystalline silicon module types as well as thin-film modules. It does not apply to non-long-term applications such as flexible modules installed in awnings or tenting, and Part 2 states that it does not apply to modules used with concentrated sunlight, although it may be used for low concentrator modules of 1 to 3 suns. Concentrating technologies are covered separately; see the CASRAI guide to concentrating solar power for the plant types that fall outside this series.

What is a photovoltaic module in the context of solar energy?

A photovoltaic module is a packaged, weather-protected assembly of interconnected photovoltaic cells that converts sunlight directly into electrical energy. It is the unit that is mounted in an array and wired into a system. The module is what IEC 61215 tests: not the individual cell, and not the complete installation with its inverter and mounting structure.

The test list in Part 2 reflects that definition. It examines the module as a finished product: its visible condition, its electrical output, its insulation, its junction box and cord anchorage, its bypass diodes and its response to mechanical, thermal and humidity stress. The amount of sunlight a site receives is a separate question; the CASRAI guide to solar irradiance explains how it is described.

How the IEC 61215 series is organised

Search results for the standard are dominated by individual store listings with long part numbers such as 61215-1-2:2021 or 61215-2:2021. The series is easier to read as a set of roles. The table below summarises the parts discussed on this page and the one companion standard people most often confuse with them. It is based on the IEC webstore pages and the IEC 61215-2 front matter listed in the sources.

Document What it does Edition and date stated by IEC
IEC 61215-1 General test requirements for design qualification and type approval of terrestrial PV modules; scope, definitions and how the series is applied Edition 2.0, 2021-02-23 (includes the May 2021 corrigendum)
IEC 61215-1-1 Special requirements for testing crystalline silicon PV modules Edition 2.0, 2021-02-23
IEC 61215-1-x (further Part 1 documents) Technology-specific special requirements; for example the 61215-1-2 document for CdTe thin-film modules appears in store listings Listed by technology; check the edition on the IEC webstore for the technology you need
IEC 61215-2 Test procedures: the module quality tests (MQT) that implement the requirements Edition 2.0, 2021; technical revision that cancels the 2016 first edition
IEC 61730-1 Fundamental construction requirements for PV modules for safe electrical and mechanical operation Edition 3.0, 2023-09-13
IEC 61730-2 Testing requirements that accompany IEC 61730-1 Referred to by the IEC 61730-1 page

In plain terms, Part 1 says what has to be demonstrated, the technology-specific Part 1-x documents adjust that for a given cell technology, and Part 2 describes how each test is carried out. IEC 61215-1-1, for example, applies to all crystalline silicon flat-plate modules, repeats that results are not a lifetime prediction, and says that users in places where the 98th percentile operating temperature exceeds 70 °C should consider the higher-temperature test conditions in IEC TS 63126.

The module quality tests in IEC 61215-2

IEC 61215-2:2021 organises its test procedures as numbered module quality tests, abbreviated MQT. The contents list shows the following groups of tests, which the data table below sets out in full with their clause numbers. The grouping here is an editorial reading of the test names, not wording from the standard.

  • Appearance and electrical performance: visual inspection (MQT 01), maximum power determination (MQT 02), measurement of temperature coefficients (MQT 04), performance at STC (MQT 06.1) and performance at low irradiance (MQT 07).
  • Electrical safety checks: insulation test (MQT 03) and wet leakage current test (MQT 15).
  • Environmental and climatic stress: outdoor exposure (MQT 08), UV preconditioning (MQT 10), thermal cycling (MQT 11), humidity-freeze (MQT 12) and damp heat (MQT 13).
  • Mechanical stress: static mechanical load (MQT 16), hail (MQT 17), cyclic (dynamic) mechanical load (MQT 20) and bending (MQT 22).
  • Component and construction checks: hot-spot endurance (MQT 09), robustness of terminations including junction box retention and cord anchorage (MQT 14) and bypass diode testing (MQT 18).
  • Degradation and stabilisation: stabilization (MQT 19, including initial stabilization, final stabilization and a BO LID stress-specific stabilization) and the potential induced degradation test (MQT 21).

The standard also keeps a placeholder section 4.5, “formerly NMOT”, where the nominal module operating temperature test used to sit, so the numbering of the later tests has not shifted since the first edition. The data table lists the tests with their clause numbers and shows which three were added in the 2021 edition.

For a laboratory, the useful point is that every MQT has a defined purpose, apparatus and procedure in Part 2, and most carry final measurements and requirements clauses. That structure is why accredited test laboratories can run the same sequence on different module designs and report against the same clause numbers. The exact test sequence and pass criteria are in the standard itself, which is a paid publication, and are not reproduced here.

What changed in the 2021 edition

Edition 2 of both Part 1 and Part 2 was published in 2021 and replaces the 2016 edition. The IEC webstore page for Part 1 and the foreword of Part 2 list the changes, which can be grouped as follows.

New tests

  • Cyclic (dynamic) mechanical load testing, added as MQT 20 in Part 2. Part 1 lists a test taken from IEC TS 62782, the technical specification on cyclic dynamic mechanical load testing.
  • A potential induced degradation test, added as MQT 21 in Part 2. Part 1 lists a test taken from IEC TS 62804-1.
  • A bending test for flexible modules, added as MQT 22.

New or clarified methods

  • Test methods required for flexible modules and definitions, references and instructions for performing design qualification and type approval on bifacial PV modules.
  • Clarified requirements for power output measurements, and revised simulator requirements intended to make the uncertainty well defined and minimised.
  • A correction to the hot-spot endurance test: the procedure for monolithically integrated thin-film technologies (MQT 09.2) had included two sections that are only appropriate for silicon modules.
  • In the bypass diode thermal test (MQT 18), a selection of three diodes rather than all diodes.
  • Weights added to the junction box during 200 thermal cycles, and a requirement that retesting be performed according to IEC TS 62915.

Removed

  • The nominal module operating temperature (NMOT) test and the associated performance test at NMOT were removed from the IEC 61215 series. The webstore pages and the Part 2 foreword both state this.

A practical consequence is that a report issued against the 2016 edition and a report issued against the 2021 edition are not interchangeable. A reader comparing two datasheets should check which edition each cites and whether the module technology has its own Part 1-x document.

IEC 61215 versus IEC 61730

The two series are written for different questions and are usually applied together. The IEC webstore page for IEC 61730-1:2023 describes it as specifying “the fundamental construction requirements for photovoltaic (PV) modules” to provide safe electrical and mechanical operation, addressing protection against electrical shock, fire hazards and personal injury from mechanical and environmental stresses. IEC 61730-2 defines the requirements for testing. Modules with modified construction are qualified under IEC TS 62915, and, as in IEC 61215, guidance for terrestrial modules with a 98th percentile operating temperature above 70 °C is in IEC TS 63126.

Question IEC 61215 series IEC 61730 series
Main subject Design qualification and type approval Fundamental construction requirements for safe operation (Part 1) and testing requirements (Part 2)
Focus stated on the IEC page Suitability for long-term operation in open-air climates Electrical shock, fire hazards, and personal injury from mechanical and environmental stresses
Result is a lifetime prediction? No: “not construed as a quantitative prediction of module lifetime” The IEC page does not make that claim; it describes safety construction requirements
Latest edition read Edition 2.0 of Parts 1 and 2 (2021) IEC 61730-1 Edition 3.0 (2023-09-13)

What is the IEC 61730 standard for?

IEC 61730 is the standard for the safety qualification of PV modules. Its first part specifies and describes the fundamental construction requirements that support safe electrical and mechanical operation, and its second part defines the test requirements. A module can therefore be tested for design qualification under IEC 61215 and for safety under IEC 61730; the two are distinct documents with distinct scopes.

Who certifies a module to IEC 61215?

The foreword of IEC 61215-2 states: “IEC itself does not provide any attestation of conformity. Independent certification bodies provide conformity assessment services and, in some areas, access to IEC marks of conformity.” In other words, the IEC publishes the standard, and a certificate or test report against it comes from an independent certification body or test laboratory. When a datasheet says a module is “certified to IEC 61215”, the document to ask for is the certificate or report from that body, with the edition and the module model it covers.

Laboratories running these tests depend on calibrated irradiance and electrical measurement equipment, which is why the standard devotes attention to simulator uncertainty. The principles behind that dependence are explained in the CASRAI guide to sensor calibration and metrological traceability, and the general safety standard for laboratory electrical equipment is covered in the guide to IEC 61010-1, which is a different standard for a different kind of equipment.

What IEC 61215 does not tell you

  • It does not predict lifetime. The scope says so directly, and the Part 2 scope adds that service life depends on design, environment and operating conditions.
  • It does not cover hotter climates by default. Where 98th percentile operating temperatures exceed 70 °C, the standard recommends considering the higher-temperature test conditions in IEC TS 63126.
  • It does not cover every module type. Concentrator modules and non-long-term applications such as flexible modules in awnings or tenting are outside Part 1’s scope.
  • It does not certify factories. Users who want confidence that the tested characteristics appear consistently in a manufactured product are pointed by Part 2 to IEC 62941, regarding quality systems in PV manufacturing.
  • It is not a safety standard on its own. Safety construction requirements sit in IEC 61730.

Common misunderstandings

“IEC 61215 certifies the product warranty.” The standard says nothing about warranties; it describes tests. Lifetime and warranty statements are commercial claims, not outputs of the standard.

“One edition number applies to all technologies.” Edition 2.0 of Part 1 and Part 2 dates from 2021, but technology-specific Part 1-x documents carry their own numbers, so the edition that matters for a CdTe module is the one that appears in the CdTe document’s listing.

“IEC 61215 and IEC 61439 are related.” They are not; see the next section.

Frequently asked questions

What is the IEC 61439 panel?

IEC 61439 is an unrelated standard family for low-voltage switchgear and controlgear assemblies, the electrical distribution and control panels found in buildings and plants. The IEC webstore page for IEC 61439-1 (2011 edition, since withdrawn on 2020-05-05 and replaced by a third edition in 2020) states that it applies to assemblies where the rated voltage does not exceed 1,000 V a.c. or 1,500 V d.c., and that Part 1 cannot be used alone to specify an assembly or to determine conformity: assemblies must comply with the relevant later part of the series. It has no role in the design qualification of PV modules.

What is a photovoltaic module in the context of solar energy?

It is the packaged assembly of interconnected photovoltaic cells that produces electricity from sunlight and is the unit tested under IEC 61215 and IEC 61730. See the section above for what the tests examine.

What is IEC in an ISO standard?

IEC stands for the International Electrotechnical Commission, a worldwide organisation for standardisation made up of national electrotechnical committees; its object is to promote international co-operation on standardisation questions in the electrical and electronic fields. It is a separate body from the International Organization for Standardization (ISO). The IEC 61215-2 foreword states that “IEC collaborates closely with the International Organization for Standardization (ISO)”, and the document itself was drafted in accordance with the ISO/IEC Directives, Part 2. A standard numbered “ISO/IEC” is published jointly; IEC 61215 is an IEC standard prepared by IEC technical committee 82, Solar photovoltaic energy systems.

What is the IEC 61730 standard for?

It sets fundamental construction requirements (Part 1) and testing requirements (Part 2) so that PV modules operate safely, covering electric shock, fire and injury from mechanical and environmental stresses. See the comparison table above.

Is an IEC 61215 pass a prediction of module lifetime?

No. IEC states that test results are not construed as a quantitative prediction of module lifetime.

Which edition of IEC 61215 is current?

The IEC webstore lists edition 2.0 of IEC 61215-1 and IEC 61215-1-1, both dated 2021-02-23, and the 2021 edition 2.0 of IEC 61215-2, each replacing the 2016 first edition. Check the IEC webstore for amendments to a particular part before citing it.

Sources

Data: IEC 61215-2:2021 module quality tests (MQT) with clause numbers and 2021 edition changes

Each module quality test listed in the contents of IEC 61215-2 edition 2.0 (2021), with its clause number and the change, if any, that the standard's foreword lists against the 2016 edition. Compiled from the standard's published front matter and the IEC webstore page for Part 1.

Period covered: 2021.

IEC 61215-2:2021 module quality tests (MQT) with clause numbers and 2021 edition changes
TestTest nameClause in IEC 61215-2:2021Change against 2016 edition per foreword
MQT 01Visual inspection4.1No change listed in foreword
MQT 02Maximum power determination4.2No change listed in foreword
MQT 03Insulation test4.3No change listed in foreword
MQT 04Measurement of temperature coefficients4.4No change listed in foreword
MQT 06.1Performance at STC4.6No change listed in foreword
MQT 07Performance at low irradiance4.7No change listed in foreword
MQT 08Outdoor exposure test4.8No change listed in foreword
MQT 09Hot-spot endurance test4.9Procedure corrected for MQT 09.2
MQT 10UV preconditioning test4.10No change listed in foreword
MQT 11Thermal cycling test4.11Weights added to junction box (Part 1)
MQT 12Humidity-freeze test4.12No change listed in foreword
MQT 13Damp heat test4.13No change listed in foreword
MQT 14Robustness of terminations4.14No change listed in foreword
MQT 15Wet leakage current test4.15No change listed in foreword
MQT 16Static mechanical load test4.16No change listed in foreword
MQT 17Hail test4.17No change listed in foreword
MQT 18Bypass diode testing4.18Three diodes selected for thermal test
MQT 19Stabilization4.19No change listed in foreword
MQT 20Cyclic (dynamic) mechanical load test4.20Added in 2021 edition
MQT 21Potential induced degradation test4.21Added in 2021 edition
MQT 22Bending test4.22Added in 2021 edition

Sources

Compiled by CASRAI from the sources above. Free to reuse under CC BY 4.0 with attribution.

Follow CASRAI

Research-administration guidance, standards updates and independent tool reviews.

Ask CASRAI · full access

Ask about IEC 61215: PV Module Design Qualification Standard Explained

Full access: large monthly usage, up to 10 source passages behind each answer, and MCP and API access for Claude Code, Codex and other CLIs. Cancel any time.

An AI assistant for research: funder rules, compliance, methods and publishing. It links the sources behind its answers and labels answers that come from a web search.

Answers draw on CASRAI's guides and dictionary plus the federal and funder documents we index: Federal Register, Grants.gov, Regulations.gov and UKRI.

Works on this site and inside Claude, Cursor and the AI tools you already use.

Everything CASRAI publishes — this page, the dictionary, the guides and the news — stays open to read, with no account and no card.

Referenced across the research world

University of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logoUniversity of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logo
  • University of Cambridge logo
  • Columbia University logo
  • Crossref logo
  • University of Edinburgh logo
  • Harvard University logo
  • University of Oxford logo
  • Princeton University logo
  • Stanford School of Medicine logo
  • University College London logo
  • ORCID logo

View CASRAI adoption →