Skip to main content
v2026.11,986 entries · CC-BY 4.0

Industrial Hygiene Sampling: Air, Dust and Surface Methods Explained

How industrial hygiene sampling works: OSHA sampler choices for dust, fume and surfaces, full-shift rules, monitoring intervals and QC.

Written and maintained by CASRAI Editorial Board

Published

On this page

Industrial hygiene sampling is the measurement of workplace exposure to chemical and physical agents, most often by drawing air through a collection medium on a worker’s pump and sending it to a laboratory, so that the result can be compared with an exposure limit. Which sampler, filter and duration you use depends on the contaminant, and how often you repeat it depends on the substance-specific standard.

This page follows OSHA’s own technical guidance for personal air sampling and surface wipe sampling. It is occupational exposure information for researchers, lab and facility managers and safety staff; it is not advice for any individual and does not replace a competent industrial hygienist or your institution’s chemical hygiene plan.

Definition and scope

OSHA describes industrial hygiene as the science and art devoted to the anticipation, recognition, evaluation and control of environmental factors that can harm workers’ health. Sampling belongs to the evaluation step: it turns a suspected hazard into a number. The hazards OSHA’s training library groups together are air contaminants, chemical, biological, physical and ergonomic factors, and this page deals with the first two: air contaminants (dusts, fumes, fibres, vapours) and contaminants that settle on surfaces.

Sampling is only one of the tools. A laboratory that wants to know whether staff are over an exposure limit for a solvent or a metal dust uses personal sampling; a laboratory that wants to know whether benches, door handles or lockers carry residue uses surface sampling. Neither answers questions about biological agents, noise or ergonomics, which need different methods.

What are the four basic principles of industrial hygiene?

The four principles are anticipation, recognition, evaluation and control of workplace hazards. In practice they run in sequence:

  • Anticipation and recognition: a worksite analysis identifies which jobs, workstations and tasks may pose a health risk, and which category of hazard each one is.
  • Evaluation: exposures are measured and judged against limits. This is where air and surface sampling sit.
  • Control: in OSHA’s order of priority, engineering controls first (remove or reduce the hazard at its source, or isolate workers from it), then work practice controls (procedures, maintenance, housekeeping), then administrative controls (scheduling high-exposure tasks when the fewest workers are present), and personal protective equipment when other controls are not feasible or while they are being put in place.

The practical consequence is that a sampling result is never the end product. It is evidence used to decide whether the controls on a task are adequate. For the limits sampling results are compared with, see permissible exposure limits (PELs, TLVs and RELs) in the laboratory and the NIOSH Pocket Guide.

What is chemical sampling?

Chemical sampling is the collection of a measured quantity of workplace air (or a surface wipe or bulk material) so that a laboratory can determine how much of a named chemical it contains. For air contaminants, OSHA’s Technical Manual describes personal sampling: a pump pulls air at a known flow rate through a filter or sorbent held in the worker’s breathing zone, and the result is expressed as a concentration over a time period.

Screening versus compliance sampling

OSHA separates two kinds of measurement. Screening tools such as detector tubes, direct-reading meters and thermal desorption tubes give instantaneous information that is used to plan sampling, for example to find the highest-exposure areas and workers. Compliance sampling is a breathing-zone sample taken over the averaging period that the applicable standard specifies. For a 15-minute short-term limit, that means sampling the 15-minute period with the greatest exposure potential. Screening results guide the plan but do not replace the compliance sample.

Planning the strategy

The Technical Manual’s strategy is built on preparation rather than equipment:

  • Use the laboratory’s method information for each analyte (media, flow rate, sample volume, interferences) and order extra media in case a sample overloads.
  • Walk the process to identify tasks, materials, work practices and existing controls, and update the plan with screening results and employee interviews.
  • Sample the highest-risk employees, considering proximity to the source, duration, air movement and task frequency, and consider different work shifts.
  • Use the vapor hazard ratio to prioritise chemicals, and check whether chemicals in a mixture could have additive or synergistic effects.

Where the sampler goes

The breathing zone is a hemispheric area forward of the shoulders, within a radius of about 6 to 9 inches of the worker’s nose and mouth. For a worker who wears a respirator, the sampler is placed outside the respirator so the result can be used to evaluate the respirator’s assigned protection factor. Under a welding helmet, the cassette goes inside the helmet at the collar or shoulder, because a helmet alone typically reduces breathing-zone exposure.

What are the different methods for sampling dust?

OSHA’s Technical Manual distinguishes total dust, respirable dust, welding fume, asbestos fibres and respirable crystalline silica, each with its own sampler and media. The data table below sets them side by side. The key points:

  • Total dust is collected on a pre-weighed PVC filter at a maximum of 2 L/min, with a maximum sampling time of 480 minutes.
  • Respirable dust needs a size-selective sampler following the ISO/ACGIH/CEN convention, whose 50% cut point is 4.0 µm aerodynamic diameter. The Dorr-Oliver cyclone runs at 1.7 L/min and collects the respirable fraction on a pre-weighed PVC filter. Cyclones must be kept vertical, so where workers stoop, crawl or climb and a cyclone could invert, an inverting-tolerant sampler such as the SKC PPI is used instead.
  • Welding fume uses a 37-mm mixed cellulose ester filter (MCEF); a 25-mm filter may be used if the 37-mm does not fit under the helmet, with extra care to avoid overloading.
  • Asbestos uses a 0.8-µm, 25-mm MCEF in an electrically conductive cassette with a 50-mm extension cowl, which prevents electrostatic fibre loss. The cap is removed and the open face points downward in the breathing zone.
  • Crystalline silica must be collected with a respirable size-selector. Without one the sample is treated as total dust and the silica limit cannot be applied to it.

Whatever the dust, check media during the shift: loose material, a darkened filter or a falling flow rate all indicate overloading.

Outside OSHA, the NIOSH Manual of Analytical Methods (fourth edition) lists separate laboratory methods for the same split: method 0500 for particulates not otherwise regulated, total, and method 0600 for particulates not otherwise regulated, respirable. A sampling plan should be matched to the analytical method the laboratory will use. Direct-reading instruments can screen airborne dust ahead of sampling; see dust monitors for what those instruments do.

Surface and wipe sampling

Surface sampling assesses contamination that could reach workers by skin contact, by ingestion from contaminated food or drink, or by inhalation of resuspended settled dust. A wipe, often dipped in distilled water or another suitable solvent, is drawn across a surface. The customary quantitative area is 10 cm × 10 cm (100 cm²), marked with a template that is cleaned between uses or is single-use. Irregular items such as door or tool handles can only be wiped qualitatively. Because percent recovery varies with surface texture, solvent and technique, OSHA notes that wipe sampling may be only semi-quantitative, and it states that no OSHA standards currently specify acceptable surface limits. Colorimetric swabs and X-ray fluorescence readings are screening tools, with a laboratory wipe used to confirm.

How often should air sampling be performed?

There is no single interval. How often you sample is set by the substance-specific OSHA standard that applies, and by what the previous results showed. Two standards illustrate the pattern.

Standard Limit Periodic monitoring interval
Chromium (VI), 29 CFR 1910.1026 PEL 5 µg/m³ and action level 2.5 µg/m³, both 8-hour TWAs At least every 6 months at or above the action level; at least every 3 months above the PEL. Monitoring may stop once a result below the action level is confirmed by another taken at least 7 days later.
Asbestos, 29 CFR 1910.1001 0.1 fibre/cm³ 8-hour TWA; 1.0 fibre/cm³ over 30 minutes Where exposure may reasonably be expected to exceed the limits, sampling at intervals no greater than 6 months. Initial monitoring is not required if objective data show asbestos cannot be released at or above the limits.

Within a single sampling event the question is different: how long to run a sample. OSHA defines full-shift sampling as at least the work shift minus one hour (7 hours of an 8-hour shift). Sampling time cannot exceed the method’s recommended maximum, so longer periods use multiple samples. Shifts longer than 8 hours are handled either by sampling the worst continuous 8 hours or by collecting several samples across the shift and using the worst 8 hours in total.

Worked arithmetic: TWA and minimum sampling time

These two calculations are the ones that most often go wrong. The numbers below are hypothetical, chosen only to show the arithmetic.

8-hour TWA. OSHA counts no more than 8 hours of sampling in an 8-hour TWA and averages unsampled time in as zero exposure. If a pump runs for 7 hours of an 8-hour shift and measures 0.40 mg/m³, the TWA is (0.40 × 7) ÷ 8 = 0.35 mg/m³. If the pump had run 8 hours at 0.40, the TWA would be 0.40.

Minimum sampling time. The Technical Manual gives Tmin = LOQ ÷ (OEL × r), where LOQ is the limit of quantitation (mass per sample), OEL is the occupational exposure limit (mass per volume) and r is the sampling rate (volume per minute). For a hypothetical method with an LOQ of 10 µg per sample, an OEL of 50 µg/m³ and a rate of 2 L/min (0.002 m³/min): Tmin = 10 ÷ (50 × 0.002) = 100 minutes. Sampling for less than that risks a result below the quantitation limit even when the air is at the limit.

Quality-control checklist from the Technical Manual

Item What OSHA’s manual states
Field blanks One per requested analysis and per media lot number, usually; at least two for asbestos. Taken at the same worksite and period, opened in a clean area, no air drawn through them, handled and shipped like exposure samples.
Pump calibration Before and after each day of sampling, with the same type of media used in the field. Calibration media are never used as a sample or blank. Label pumps and calibrate spares.
Acclimation Let devices acclimate at least 15 minutes to site conditions; check manufacturer temperature specifications below 41°F or above 95°F.
Records Pump serial number, initial flow rate, calibration location temperature and pressure, and pump start and stop times to the nearest minute.
Sealing and identification Unique sample number on each sampler; OSHA-21 seal applied as soon as possible after removal from the pump; chain of custody per the manual’s appendix.
Overloading Order extra media and check during the shift for loose material, darkened filters or reduced flow.

A laboratory writing its own monitoring procedures can fold these checks into its chemical hygiene plan. If the concern is airborne microorganisms rather than chemical contaminants, the relevant comparison is viable air samplers, a different method family.

Common misunderstandings

  • “A direct-reading meter result is a compliance result.” OSHA’s manual states that screening tools guide the sampling plan and do not replace compliance sampling.
  • “Longer is always better.” The method’s recommended sampling time is a maximum. Exceeding it risks overloading; the answer is more samples, not one longer one.
  • “Any dust sample can be compared with the silica limit.” Only a respirable sample collected with a size-selector can be.
  • “There is a standard surface limit.” OSHA states none is specified; wipe results are used qualitatively, and a figure quoted by an industry is practice, not an OSHA limit.
  • “A not-detected result means the air is clean.” For silica, the manual says to check that sampling was adequate and to sample longer or use a higher-flow sampler.

Frequently asked questions

What are the four basic principles of industrial hygiene?

Anticipation, recognition, evaluation and control of environmental factors that can harm workers’ health, according to OSHA’s definition. Sampling supports the evaluation step.

What is chemical sampling?

Collecting air, a surface wipe or bulk material in a controlled way so a laboratory can quantify a named chemical, typically using a calibrated pump and a filter or sorbent in the worker’s breathing zone.

How often should air sampling be performed?

As often as the applicable substance-specific standard requires: for example at least every 6 months at or above the action level and every 3 months above the PEL for chromium (VI), and at intervals no greater than 6 months for asbestos where exposure may exceed the limits.

What are the different methods for sampling dust?

Total dust on a pre-weighed PVC filter, respirable dust with a size-selective cyclone or similar sampler (4.0 µm cut point), welding fume on a mixed cellulose ester filter, asbestos on a conductive cassette with a cowl, and surface wipes for settled dust.

What counts as full-shift sampling?

At least the work shift minus one hour, such as 7 hours of an 8-hour shift. Unsampled time is averaged in as zero in the TWA.

Where is the sampler placed?

In the breathing zone, within roughly 6 to 9 inches of the nose and mouth, and outside any respirator.

Sources

  • OSHA Technical Manual, Section II, Chapter 1: Personal Sampling for Air Contaminants, osha.gov (read 2026-11-21).
  • OSHA Technical Manual, Section II, Chapter 2: Surface Contaminants, Skin Exposure, Biological Monitoring and Other Analyses, osha.gov (read 2026-11-21).
  • OSHA, 29 CFR 1910.1026 Chromium (VI), osha.gov (read 2026-11-21).
  • OSHA, 29 CFR 1910.1001 Asbestos, osha.gov (read 2026-11-21).
  • OSHA Training Library, Industrial Hygiene, osha.gov (read 2026-11-21).
  • NIOSH Manual of Analytical Methods, 4th edition, Method Numbers 0000-2000, cdc.gov (read 2026-11-21).

Data: OSHA-described sampler and media by airborne contaminant

Compares the sampler, collection medium, flow rate and placement notes that OSHA's Technical Manual gives for each class of airborne contaminant, compiled from the manual's personal sampling chapter.

OSHA-described sampler and media by airborne contaminant
ContaminantSampler or cassetteCollection mediumFlow rate or limit (as stated)Placement or handling note
Total dustSampling cassettePre-weighed PVC filterMaximum 2 L/min, up to 480 minCheck for overloading: loose material, darkening, reduced flow
Respirable dustSize-selective cyclone (Dorr-Oliver)Pre-weighed PVC filter1.7 L/min; 50% cut point 4.0 µmKeep cyclone vertical; use SKC PPI where it could invert
Welding fumeCassette inside helmet37-mm mixed cellulose ester filterNot specified in this section25-mm filter if 37-mm does not fit; place at collar or shoulder inside helmet
AsbestosConductive cassette with 50-mm extension cowl0.8-µm, 25-mm mixed cellulose ester filterNot specified in this sectionOpen face pointing downward in the breathing zone; seal bottom joint
Respirable crystalline silicaRespirable size-selector such as a Dorr-Oliver cycloneRespirable sample; analysis requested as crystalline silicaNot specified in this sectionWithout a size-selector the sample is treated as total dust
Surface contaminationWipe with 10 cm x 10 cm templateWipe moistened with distilled water or suitable solventNot applicableSemi-quantitative; no OSHA surface limits specified

Sources

Compiled by CASRAI from the sources above. Free to reuse under CC BY 4.0 with attribution.

Follow CASRAI

Research-administration guidance, standards updates and independent tool reviews.

Ask CASRAI · full access

Ask about Industrial Hygiene Sampling: Air, Dust and Surface Methods Explained

Full access: large monthly usage, up to 10 source passages behind each answer, and MCP and API access for Claude Code, Codex and other CLIs. Cancel any time.

An AI assistant for research: funder rules, compliance, methods and publishing. It links the sources behind its answers and labels answers that come from a web search.

Answers draw on CASRAI's guides and dictionary plus the federal and funder documents we index: Federal Register, Grants.gov, Regulations.gov and UKRI.

Works on this site and inside Claude, Cursor and the AI tools you already use.

Everything CASRAI publishes — this page, the dictionary, the guides and the news — stays open to read, with no account and no card.

Referenced across the research world

University of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logoUniversity of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logo
  • University of Cambridge logo
  • Columbia University logo
  • Crossref logo
  • University of Edinburgh logo
  • Harvard University logo
  • University of Oxford logo
  • Princeton University logo
  • Stanford School of Medicine logo
  • University College London logo
  • ORCID logo

View CASRAI adoption →