Written and maintained by CASRAI Editorial Board
Published · Last updated
On this page
An instrument stringer is a stainless-steel holder for surgical instruments. FDA device records list it as a general-use manual surgical instrument, and some records list it as a sterilization-tray accessory. This page describes products and general use; it is not medical advice.
Who uses it: staff who assemble, reprocess or specify surgical instrument sets, and students learning how instrument sets are held together. After reading, you should be able to read a stringer listing (lock style, length by width, reusable or single-use) and know which FDA classification applies.
What an instrument stringer is
An instrument stringer is a bar, rod or open-ended holder that instruments are threaded or hooked onto so a set stays together. In FDA’s AccessGUDID data, as served by openFDA (index last updated 2026-10-01), 303 device records describe the product as an “instrument stringer”, for example “U-Shaped Instrument Stringer, 14-inch x 5.5-inch” and “Instrument Stringer, Surgical stainless steel, 6-inch x 5.5-inch”. Material is given as surgical stainless steel or surgical-grade stainless steel in the records that name one.
The records name the product and its dimensions; they do not describe its purpose in words. The use described here (keeping instruments together in a set) is an editorial summary of how the product is named and listed, not a quotation from a regulator.
Types and lock styles
Manufacturers describe stringers by shape and by how the closure works. These names come straight from the product descriptions in the FDA records.
| Type (as named in records) | Key difference in the description | Example description |
|---|---|---|
| U-shaped, open end | Open at one end | “Instrument Stringer, U-shaped, open end, 16″ x 2 3/4″” (gSource) |
| Open-ended | Open end, stated width and length | “open-ended instrument stringer, 2 1/2″ (6.3 cm) wide, 8″ (20.3 cm)” (Novo Surgical) |
| T-bar | T-bar form, listed by length | “T-BAR INSTRUMENT STRINGER 6″” (SteriBest); also 8″, 12″ and 16″ |
| Center latch / center locking | Latch or lock at the centre; some with a hook | “12” L x 5.75″ W CENTER LATCH INSTRUMENT STRINGER”; “center locking instrument stringer, w/ hook” (Novo Surgical) |
| Pin lock | Locking pin | “18” L X 3″ W PIN LOCK INSTRUMENT STRINGER”; “with secure locking device (Pin-Lok)” (Hayden Medical) |
| Pin and socket / ball and socket | Pin-and-socket or ball-and-socket closure | “6” L x 2.75″ W PIN & SOCKET INSTRUMENT STRINGER”; “6” L x 2.75″ BALL & SOCKET INSTRUMENT STRINGER” |
| With bar or lock | Bar or lock named in the description | “INSTRUMENT STRINGER W/BAR, 12″” (HNM Medical); “POSILOCK INSTRUMENT STRINGER, 2 1/2″X6″” (HNM Medical) |
Source for the table: openFDA device UDI records, checked 2026-10-30.
Sizes in FDA records
Stringers are described by length, and often by width. The figures below are the ones that appear in the records; they show the range listed, not a recommended size.
| Dimension | Values that appear in the records |
|---|---|
| Length | 4″, 6″, 6.25″, 8″, 10″, 12″, 14″, 16″, 18″; also 40 cm (Marina Medical) |
| Width | 2.5″, 2.75″, 3″, 4.0″, 5.5″, 5.75″ |
| Example, pin and socket | 6″ L x 2.75″ W and 8″ L x 2.75″ W (SteriBest) |
| Example, pin lock | 6.25″ L x 4.0″ W; 8″ L x 5.5″ W; 12″, 14″ and 16″ L x 5.5″ W; 18″ L x 3″ W (SteriBest) |
| Example, center latch | 8″ L x 5.75″ W; 12″ L x 3″ W and 12″ L x 5.75″ W; 16″ L x 3″ W; 18″ L x 3″ W |
Source: openFDA device UDI records, checked 2026-10-30.
Reusable or single-use
Most stringer records are marked as not single-use. Ten records, all from Novo Surgical (center-locking with hook, open-ended, end-gate and Weinstein styles, all 2 1/2 inches wide, 6 to 16 inches long), are marked single-use. A record’s single-use flag is the manufacturer’s own entry, so the instructions for use for the specific product are the authority for reprocessing.
FDA classification
Most stringer records carry product code MDM (instrument, manual, surgical, general use), with some under FSM or HXD (clamp). These sit under 21 CFR 878.4800, which defines a manual surgical instrument for general use as “a nonpowered, hand-held, or hand manipulated device, either reusable or disposable, intended to be used in various general surgical procedures”. It is Class I (general controls) and exempt from premarket notification, subject to the limitations in 21 CFR 878.9.
A different classification appears for some stringers listed with sterilization trays. A Restore Medical Solutions record for an expandable stringer (9 and 10 inch) “for Restore Intelligent Sterilization Tray”, and two STERIS V. Mueller records (10 and 16 inch), are listed under product code KCT, sterilization wrap containers, trays, cassettes and other accessories. That code falls under 21 CFR 880.6850, where a sterilization wrap is “intended to be used to enclose another medical device that is to be sterilized by a health care provider”, and the classification is Class II (performance standards). The Restore record lists moist heat or steam as its sterilization method.
The same product name can therefore sit in Class I or Class II depending on how the manufacturer listed it. Related pages: sterilization containers, autoclave trays and sterilization wrap.
How to read a stringer listing
- Name and shape: U-shaped, open-ended or T-bar describes the form.
- Closure: center latch, pin lock, pin and socket, ball and socket, or hook, as the maker names it.
- Dimensions: length is usually listed first, with width after “x” or “W”.
- Material: stainless steel where stated.
- Single-use flag and product code: these show the maker’s entry for intended use and the FDA class.
Cleaning, loading limits and sterilization parameters depend on the manufacturer’s instructions for use and are not covered by the FDA records above. A stringer is one part of a set; wound closure kits are another example of a contents-defined set.
FAQ
What is an instrument stringer?
It is a stainless-steel holder that instruments are placed on to keep a set together. FDA records list it as a manual surgical instrument for general use, and 303 records use the name.
Are instrument stringers reusable?
Most records are marked not single-use; ten Novo Surgical records are marked single-use. Check the product’s instructions for use.
What FDA class is an instrument stringer?
Most are Class I under 21 CFR 878.4800 (product code MDM). Stringers listed as sterilization-tray accessories under product code KCT fall under 21 CFR 880.6850, Class II.
What sizes do stringers come in?
Records list lengths from 4 to 18 inches (and 40 cm) and widths from 2.5 to 5.75 inches.
Sources
- openFDA, Device UDI (AccessGUDID data), https://api.fda.gov/device/udi.json, searched 2026-10-30; index last updated 2026-10-01.
- 21 CFR 878.4800, Manual surgical instrument for general use, https://www.law.cornell.edu/cfr/text/21/878.4800, checked 2026-10-30.
- 21 CFR 880.6850, Sterilization wrap, https://www.law.cornell.edu/cfr/text/21/880.6850, checked 2026-10-30.
- openFDA, Device classification, https://api.fda.gov/device/classification.json, checked 2026-10-30.