Oxidation-Fermentation (OF) Test: Reading Results

How the oxidation-fermentation (OF) test works, how to read the two tubes, and where UK SMI and ASM differ on sealants and QC.

Written and maintained by CASRAI Editorial Board

Published · Last updated

On this page

The oxidation-fermentation (OF) test shows how a bacterium breaks down a carbohydrate, usually glucose: oxidatively (acid only where oxygen is present), fermentatively (acid with or without oxygen), or not at all. It is read from the colour of a semi-solid medium in two tubes, one open to air and one sealed. Labs use it mainly to separate Gram-negative rods and to tell Staphylococcus from Micrococcus. This page is general laboratory reference, not medical advice and not a bench protocol.

Short answer

An organism that makes acid in both the open and the sealed tube is fermentative. One that makes acid only in the open tube is oxidative. One that changes neither tube is non-saccharolytic for that carbohydrate. The UK Standards for Microbiology Investigations (UK SMI) describe the test as also known as the “oxferm” or OF test, and as sometimes called the Hugh and Leifson test.

Definition and scope

The method comes from Hugh and Leifson’s 1953 paper on the taxonomic significance of fermentative versus oxidative carbohydrate metabolism in Gram-negative rods (J Bacteriol 66:24-26), as summarised in the American Society for Microbiology (ASM) protocol. In oxidative metabolism oxygen is the ultimate hydrogen acceptor, so the organism uses glucose only under aerobic conditions. Fermentation does not depend on oxygen (UK SMI TP 27).

UK SMI TP 27 says the test is used to differentiate species, particularly Gram-negative rods, and to separate the genera Staphylococcus and Micrococcus. The ASM protocol quotes Cowan and Steele (1965) calling it one of the most important tests in identifying aerobic bacteria.

How the test is used in practice

UK SMI and ASM describe the same design: a semi-solid medium containing a carbohydrate (usually glucose) and a pH indicator, inoculated into two tubes, with one tube sealed to create anaerobic conditions. Reading is by colour. In the ASM protocol the indicator is bromthymol blue, which turns from green to yellow as the pH falls to about 6.0.

Incubation is at 35 °C. UK SMI gives 48 hours or longer, examined daily; ASM gives 48 hours for most Gram-negative rods and 3 to 4 days for slow growers. ASM notes the result is best read within 24 to 48 hours.

What is OF medium (Hugh and Leifson medium)?

OF basal medium is a low-peptone, semi-solid medium. ASM explains why: Hugh and Leifson used more glucose and less peptone than a standard fermentation medium, because less peptone means fewer amines that neutralise weak acid, and they added dipotassium phosphate as a buffer. ASM’s recipe per litre is peptone 2.0 g, NaCl 5.0 g, glucose 10.0 g, bromthymol blue 0.03 g, agar 3.0 g and K2HPO4 0.30 g, at pH 7.1 before autoclaving. Premixed basal medium is sold without the carbohydrate, which is then added as a filter-sterilised solution after autoclaving. Other published recipes quote different agar and indicator amounts, so a lab should follow the recipe in its own SOP.

Result Open tube Sealed tube Source
Fermentative (F) Acid (yellow) Acid (yellow) ASM; UK SMI TP 27 (Enterobacteriaceae)
Oxidative (O) Acid, starting at the surface and spreading down No change ASM; UK SMI TP 27
Non-saccharolytic (-) No change, or blue at the top from amines No change ASM; UK SMI TP 27 (Alcaligenes faecalis: alkaline open tube)

The same medium can also record gas production and motility (UK SMI TP 27). Two variants are documented. For staphylococci and micrococci, UK SMI uses the Baird-Parker modification; for Gram-negative rods it uses Hugh and Leifson OF basal medium. A 1983 Journal of Clinical Microbiology paper (Knapp and Holmes, PMC270744) describes a modified OF medium for Neisseria and Branhamella with less protein relative to carbohydrate and phenol red in place of bromthymol blue. ASM adds that organisms that are oxidative on glucose can be tried on maltose, lactose, mannitol or sucrose, one tube each, without an oil overlay and with a heavy inoculum.

The OF test sits alongside other biochemical tests that classify metabolism. See also phenol red broth for carbohydrate fermentation in broth, urease test results, starch hydrolysis and gelatin hydrolysis. For the stain that usually comes first in identification, see Gram stain procedure, reagents and results.

Where it matters for labs: where the two authorities differ

The two authorities differ on several points that a lab’s SOP should settle explicitly.

Point UK SMI TP 27 (Issue 4.1, 2025) ASM protocol (2016)
Sealant over the sealed tube Mineral oil not recommended, because it is a heavy liquid petroleum and increases air diffusion; melted soft paraffin, about a 3 cm layer 1 cm mineral oil overlay
Incubation 35 °C for 48 hours or longer, examine daily 35 °C for 48 hours; slow growers 3-4 days
Screw caps Not closed too tightly Not closed tightly
Controls Quality control for every media batch, plus a negative control of OF basal medium without carbohydrate Uninoculated controls with and without oil, incubated and not incubated, because the medium may change colour at incubation temperature

Batch quality control checklist (UK SMI TP 27)

  • Oxidation: Pseudomonas aeruginosa NCTC 10662 or 12903.
  • Fermentation: Escherichia coli NCTC 10418 or 12241.
  • No reaction: Acinetobacter lwoffii NCTC 5866.
  • Gram-positive set: Micrococcus luteus NCTC 2665 (oxidative) and Staphylococcus aureus NCTC 6571 or 12973 (fermentative).
  • Negative control: OF basal medium without carbohydrate.

UK SMI also advises testing from a non-selective medium where possible (with a purity plate if the isolate came from selective agar), and, if an organism will not grow in the medium, repeating the test after enriching each tube with 2% serum or 0.1% yeast extract.

Common misunderstandings

  • A slow surface colour change is not a negative. The oxidative colour change starts at the surface and may not be apparent for several days. UK SMI warns not to mistake this for a negative reaction.
  • There is no “positive” result. ASM records the result as fermentative (F), oxidative (O) or negative (-) and states there is no positive (+) designation.
  • A blue top layer is not acid. ASM explains that blue at the top of the open tube can come from amines released by peptone breakdown, which is read as negative.
  • The sealed tube only works if it stays sealed. The sealant is what keeps the tube anaerobic, which is why the choice of sealant matters.

FAQ

What does the oxidation-fermentation test tell you?

Whether an organism uses a carbohydrate by oxidation, by fermentation, or not at all, which helps separate Gram-negative rods and distinguishes Staphylococcus from Micrococcus (UK SMI TP 27).

Why are two tubes used?

One tube is open to air and one is sealed to remove oxygen. Acid in both points to fermentation; acid in the open tube alone points to oxidation (ASM; UK SMI).

Why does the mineral oil advice differ?

ASM’s protocol uses a 1 cm mineral oil overlay, while UK SMI TP 27 recommends against mineral oil because it increases air diffusion and suggests melted soft paraffin. A lab should follow its validated SOP.

Which indicator does OF medium use?

The ASM protocol uses bromthymol blue, green at the start and yellow when acid forms. Some modified media use phenol red (Knapp and Holmes, 1983).

Sources

Follow CASRAI

Research-administration guidance, standards updates and independent tool reviews.

Ask CASRAI · free to try

Ask about Oxidation-Fermentation (OF) Test: Reading Results

2 free questions a day, no account.

An AI assistant for research: funder rules, compliance, methods and publishing. It links the sources behind its answers and labels answers that come from a web search.

Answers draw on CASRAI's guides and dictionary plus the federal and funder documents we index: Federal Register, Grants.gov, Regulations.gov and UKRI.

Works on this site and inside Claude, Cursor and the AI tools you already use.

Everything CASRAI publishes — this page, the dictionary, the guides and the news — stays open to read, with no account and no card.

Referenced across the research world

University of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logoUniversity of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logo
  • University of Cambridge logo
  • Columbia University logo
  • Crossref logo
  • University of Edinburgh logo
  • Harvard University logo
  • University of Oxford logo
  • Princeton University logo
  • Stanford School of Medicine logo
  • University College London logo
  • ORCID logo

View CASRAI adoption →