Oxygen Cylinder Parts: Valve, Cap, Pressure Relief Device and Regulator Explained

The valve, protection cap, pressure relief device and regulator of an oxygen cylinder, and what OSHA and DOT rules require of each.

Written and maintained by CASRAI Editorial Board

Last updated

This page describes products and general use; it is not medical advice.

Who uses it: clinic and laboratory staff, buyers and students who need to name the parts of an oxygen cylinder and know which of them the U.S. rules actually address. After reading, you should be able to tell the valve, protection cap, pressure relief device and regulator apart and state what the OSHA and DOT rules cited here say about each.

Scope note: the OSHA provisions quoted below come from 29 CFR 1910.253, which is OSHA’s standard for oxygen-fuel gas welding and cutting. They apply by their terms to welding and cutting workplaces. They are shown here as worked examples of how federal rules treat each cylinder part, not as a general rule for every setting. This page does not state which standard governs clinical or laboratory oxygen use; check the rules that apply to your facility, for example NFPA 99 or your own safety officer’s requirements.

What the main parts of an oxygen cylinder are

An oxygen cylinder (often called an oxygen tank) is a compressed gas cylinder fitted with a valve, normally covered by a protection cap, and with a pressure relief device. The gas is drawn off through a regulator that attaches to the valve outlet. Four parts carry specific obligations in the federal rules cited here: the valve, the valve protection cap, the pressure relief device and the regulator.

What each part does and what the rule says

The 29 CFR 1910.253 rows below are the OSHA welding and cutting standard; the 49 CFR 173.301 rows are DOT rules for cylinders offered for transport.

Part Role What the rule says Source
Cylinder valve Opens and closes the flow of gas from the cylinder Empty cylinders must have their valves closed. 29 CFR 1910.253, (b)(2)(iii)
Valve protection cap Covers the valve while the cylinder is stored or moved Where the cylinder is designed to accept a cap, the cap must always be in place, hand-tight, except when the cylinder is in use or connected for use. It must not be used for lifting cylinders from one vertical position to another. 29 CFR 1910.253, (b)(2)(iv) and (b)(5)(ii)(C)
Pressure relief device Protects the cylinder against rupture A filled cylinder offered for transport must have one or more pressure relief devices, selected and tested per CGA S-1.1, capable of preventing rupture of the normally filled cylinder (subject to listed exceptions). OSHA requires such devices to be installed and maintained per CGA S-1.1 and S-1.2. 49 CFR 173.301(f)(1); 29 CFR 1910.101(c)
Regulator Attaches to the valve outlet to deliver oxygen for use Unless connected to a manifold, oxygen from a cylinder must not be used without first attaching an oxygen regulator. 29 CFR 1910.253, (b)(5)(ii)(P)

Oxygen cylinder valve and valve types

The valve is the cylinder’s shut-off point, and OSHA requires it to be closed on an empty cylinder. The regulator connects at the valve outlet. Outlet and inlet connections for compressed gas cylinders follow the CGA V-1 standard; the specific connection numbers and the differences between valve styles are covered in the CASRAI entries on CGA fittings and CGA Pamphlet P-1.

Oxygen cylinder cap

The cap is the valve protection cap, and it stays on, hand-tight, whenever the cylinder is not in use or connected for use. Two further OSHA points matter in daily handling: the cap must not be used to lift the cylinder, and unless the cylinder is secured on a special truck, the regulator must be removed and the cap put in place before the cylinder is moved. For moving and securing, see oxygen tank cart.

Caps matter for transport as well. For DOT-specification cylinders made on or after 1 October 2007, 49 CFR 173.301(h) requires the valve assembly to be strong enough, or protected, so that no leakage occurs when the cylinder is dropped 1.8 m (6 ft) or more. A securely attached metal cap is one of the protection methods the rule lists.

Pressure relief device and what cylinder pressure means

The pressure relief device exists to keep a normally filled cylinder from rupturing. Federal rules (DOT for transport, and OSHA through 29 CFR 1910.101) require it, and they tie its selection and testing to CGA S-1.1. This page gives no pressure figures, because the rules cited here do not state a single cylinder pressure; for capacity and size designations see compressed gas cylinder sizes. Cylinder periodic testing is covered in cylinder hydrostatic testing requirements.

Regulator interface

The regulator is a separate component rather than part of the cylinder, but the rule treats it as inseparable from use: oxygen from a cylinder is not to be used without one unless the cylinder feeds a manifold. Regulator types and their markings are covered in oxygen regulator.

Safe use and handling basics

These points restate the welding and cutting rules in 29 CFR 1910.253 and are good practice as an example, not a statement of what governs every workplace.

  • Keep the valve closed on an empty cylinder.
  • Keep the protection cap on, hand-tight, unless the cylinder is in use or connected for use.
  • Never use the cap for lifting a cylinder from one vertical position to another.
  • Remove the regulator and replace the cap before moving a cylinder that is not on a special truck.

For wider handling, storage and inspection rules, see compressed gas cylinder safety and the cylinder inspection checklist.

Common mistakes

  • Lifting the cylinder by its protection cap, which OSHA prohibits.
  • Moving a cylinder with the regulator still attached when it is not secured on a special truck.
  • Leaving the cap off a stored cylinder that is designed to accept one.

FAQ

What are the parts of an oxygen tank?

The parts the federal rules address are the valve, the valve protection cap, the pressure relief device and the regulator that attaches at the valve outlet.

Does an oxygen cylinder need a cap?

Where the cylinder is designed to accept a valve protection cap, OSHA’s welding and cutting standard requires it to be in place, hand-tight, except when the cylinder is in use or connected for use (29 CFR 1910.253(b)(2)(iv)).

What are oxygen cylinder valve types?

Valve outlet and inlet connections follow CGA V-1. This page does not tabulate valve styles; see CGA fittings for connection standards.

What is the pressure in an oxygen cylinder?

The rules cited here give no single figure. The relief device required by DOT and OSHA rules is there to prevent a normally filled cylinder from rupturing.

Sources

Follow CASRAI

Research-administration guidance, standards updates and independent tool reviews.

Ask CASRAI · free to try

Ask about Oxygen Cylinder Parts: Valve, Cap, Pressure Relief Device and Regulator Explained

Ask your first 2 questions free below. Subscribers get 150 a day for $29 a month.

An AI assistant specialized in research administration. It cites the sources behind every answer, labels web answers and says when it can't answer.

Answers draw on CASRAI's guides and dictionary plus the federal and funder documents we index: Federal Register, Grants.gov, Regulations.gov and UKRI.

Works on this site and inside Claude, Cursor and the AI tools you already use.

Everything CASRAI publishes — this page, the dictionary, the guides and the news — stays free to read, with no account and no card.

Referenced across the research world

University of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logoUniversity of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logo
  • University of Cambridge logo
  • Columbia University logo
  • Crossref logo
  • University of Edinburgh logo
  • Harvard University logo
  • University of Oxford logo
  • Princeton University logo
  • Stanford School of Medicine logo
  • University College London logo
  • ORCID logo

View CASRAI adoption →

Ask CASRAI · Regulatory Radar

Research-admin question? Get an answer that links its sources.

An AI assistant specialized in research administration. Every answer links its sources to check before you act. 2 questions free, no account. $29/month after.

  • Answers draw on CASRAI's guides and dictionary plus the federal and funder documents we index: Federal Register, Grants.gov, Regulations.gov and UKRI.
  • Every answer numbers its sources and links each one, so you can check the source yourself.