OxyGo: Models, Specs, Battery Life and FDA Rules

OxyGo portable oxygen concentrators provide pulse-dose oxygen via PSA sieves. Review Standard, FIT, and NEXT specs, battery runtimes, and FDA clearance.

Written and maintained by CASRAI Editorial Board

Published

On this page

General product and technical reference for clinical engineering, durable medical equipment (DME) providers, and healthcare facilities; not individual medical advice.

Short answer

OxyGo is a family of lightweight, pulse-dose portable oxygen concentrators (POCs) engineered for ambulatory oxygen therapy. Utilizing pressure swing adsorption (PSA) zeolite sieves, OxyGo devices extract medical-grade oxygen from ambient air, delivering breath-synchronized boluses across models ranging from the ultra-compact 2.8-pound OxyGo FIT to the higher-output OxyGo NEXT. All units feature field-replaceable sieve beds and FAA flight compliance.

Definition and scope

The OxyGo device family encompasses prescription portable oxygen concentrators designed to deliver supplemental oxygen to ambulatory patients. Regulated by the U.S. Food and Drug Administration (FDA), OxyGo concentrators hold the following regulatory identity:

  • Device Classification: Regulated under 21 CFR § 868.5440 (Generator, Oxygen, Portable) as a Class II medical device.
  • Product Code & Panel: Product Code CAW; Anesthesiology and Respiratory Therapy Devices advisory committee.
  • Regulatory Clearance: Premarket notification 510(k) K252407 (applicant MV Life, LLC; Substantially Equivalent on April 23, 2026).
  • AccessGUDID Identifiers: Global Unique Device Identification records cover the Standard OxyGo (IO-300 / 1400-1000 series), OxyGo FIT (IO-400 / 1400-2000 series), and OxyGo NEXT (1400-3000u Bluetooth series).

Clinically, OxyGo devices provide pulse-dose delivery only. Unlike stationary concentrators such as the Respironics EverFlo that deliver continuous flow up to 5 L/min, OxyGo devices are built for mobility, running on rechargeable batteries, AC power, or 12V DC vehicle outlets within broader respiratory therapy equipment setups.

How it works and clinical practice

OxyGo concentrators operate through Pressure Swing Adsorption (PSA) coupled with breath-sensing bolus delivery:

Pressure Swing Adsorption Separation

An internal variable-speed compressor draws ambient air through gross particle filters and directs it into two synthetic zeolite sieve beds. Under pressure, the zeolite selectively adsorbs atmospheric nitrogen, allowing 90% (± 3%) concentrated oxygen to flow into a product reservoir. The system alternates beds: while one pressurizes and purifies oxygen, the other depressurizes, venting trapped nitrogen back to the ambient environment.

Intelligent Delivery Technology (Breath Sensing)

Unlike continuous flow devices, OxyGo units incorporate a sensitive differential pressure sensor at the cannula nozzle. The sensor detects negative pressure at the onset of inhalation, triggering a solenoid valve to release a bolus within milliseconds. This early-delivery timing ensures oxygen reaches the alveoli during active inhalation rather than pooling in anatomical dead space.

Field-Serviceable Sieve Columns

Zeolite beds naturally degrade over 12 to 24 months due to environmental moisture. OxyGo addresses this with field-replaceable sieve column pairs (model 1400-7000). Clinicians or homecare patients can release and replace the columns via a quick-release base latch without depot disassembly or tools.

Power and Charging Management

The system accepts universal AC power (100–240 V, 50–60 Hz) and DC automotive power (13.5–15.5 V), supporting continuous operation while simultaneously recharging attached lithium-ion battery modules.

The OxyGo line comprises three main tiers, differing by weight, pulse settings, and battery life:

Specification OxyGo (Standard) OxyGo FIT OxyGo NEXT
Pulse Settings Settings 1–5 Settings 1–3 (1–4 on FIT+) Settings 1–6
Max O2 Output 1,050 mL/min 630 mL/min 1,245 mL/min
Single Battery Weight 4.8 lbs (2.2 kg) 2.8–2.9 lbs (1.3 kg) 4.74 lbs (2.15 kg)
Double Battery Weight 5.8 lbs (2.6 kg) 3.3–3.4 lbs (1.5 kg) 5.73 lbs (2.60 kg)
Single Battery Runtime (Setting 2) Up to 4.5–4.75 hours Up to 2.7–3.0 hours Up to 6.25–6.5 hours
Double Battery Runtime (Setting 2) Up to 9.0–10.25 hours Up to 5.0–5.8 hours Up to 12.75–13.0 hours
Sound Level ~39 dBA (setting 2) ~39 dBA (setting 2) ~38–39 dBA (setting 2)

OxyGo FIT

The OxyGo FIT is the compact model in the line, comparable in form factor to devices like the CAIRE FreeStyle Comfort. Weighing 2.8 pounds with a single battery, it provides 3 pulse settings (expanding to 4 on the FIT+). It delivers up to 630 mL/min of oxygen and is designed for highly active users where equipment weight is the primary factor.

OxyGo NEXT

The OxyGo NEXT serves patients with higher flow needs, offering 6 pulse settings and delivering up to 1,245 mL/min. Weighing under 4.8 pounds with a single battery, it includes Bluetooth connectivity to track unit runtime and column condition.

Where it matters for clinics, transport and supply decisions

Clinical teams and durable medical equipment providers focus on three practical considerations:

Billing and Reimbursement (HCPCS Codes)

Medicare DMEPOS fee schedules categorize portable oxygen concentrators separately from stationary equipment:

  • HCPCS Code E1392: Covers Portable oxygen concentrator, rental. This code includes the portable unit, batteries, charger, and standard accessories.
  • Relationship to HCPCS E1390: E1390 reimburses stationary continuous-flow units. E1392 is billed when documented clinical criteria (such as room-air desaturation during ambulation) demonstrate portable oxygen necessity.

Commercial Aviation and FAA Travel Rules

OxyGo units comply with FAA criteria under 14 CFR § 121.574 for commercial aircraft passenger cabin use. Airlines require passengers to notify staff in advance and carry sufficient oxygen concentrator battery capacity to cover 150% of scheduled flight duration to protect against transit delays. Lithium-ion batteries must remain in carry-on luggage per UN 38.3 standards.

Fleet Economics and Sieve Maintenance

Unlike concentrators requiring factory service when sieves saturate, OxyGo’s modular columns (1400-7000) allow DME providers to mail replacement cartridges directly to clients, reducing field service visits and depot shipping costs.

Common misunderstandings

  • Pulse settings equal continuous liters per minute: A setting of “2” delivers a calibrated bolus per breath, not 2 L/min of continuous flow. Pulse output matches physiological needs during inhalation only.
  • Compatibility with CPAP/BiPAP circuits: OxyGo concentrators cannot deliver oxygen into CPAP or BiPAP circuits. Positive airway mask pressure prevents the sensor from detecting spontaneous inspiratory effort.
  • Compatibility with bubble humidifiers: OxyGo units do not accept bubble humidifiers. Circuit humidity damages internal sensors, and pulse boluses do not cause the airway drying seen with continuous high-flow gas.
  • Sieve replacement requires unit replacement: A sieve alert indicates zeolite saturation, which is resolved by sliding in replacement column cartridges, not by discarding the machine.
  • Battery life is static: Battery runtime drops at higher pulse settings and higher respiratory rates, requiring additional battery modules for extended outings.

Frequently asked questions

What is the difference between OxyGo and OxyGo FIT?

Standard OxyGo offers 5 pulse settings, up to 10 hours of runtime with a double battery, and weighs 4.8 pounds. OxyGo FIT weighs 2.8 pounds, offers 3 or 4 pulse settings, and provides up to 5.8 hours of battery life.

Are OxyGo concentrators approved for commercial flights?

Yes. All OxyGo models meet FAA acceptance criteria under 14 CFR § 121.574. Airlines require battery power covering 150% of the flight duration, with spare batteries kept in carry-on bags.

Can OxyGo run while charging?

Yes. OxyGo concentrators operate continuously on AC or DC power while concurrently charging attached battery packs.

How long do OxyGo sieve beds last?

Sieve columns typically last 12 to 24 months depending on humidity and operating hours. Units display a prompt when replacement columns are required.

Which HCPCS code applies to OxyGo?

OxyGo portable units are billed under HCPCS code E1392 (portable oxygen concentrator rental). Stationary units use code E1390.

Sources

  • U.S. Food and Drug Administration. Premarket Notification 510(k) K252407: OxyGo Portable Oxygen Concentrator (1400-7000). Applicant: MV Life, LLC. Clearance Date: April 23, 2026. Classification: 21 CFR § 868.5440, Product Code CAW, Class II. URL: https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpmn/pmn.cfm?ID=K252407 (Accessed November 9, 2026).
  • U.S. Food and Drug Administration. 21 CFR § 868.5440: Portable Oxygen Generator. Code of Federal Regulations, Title 21, Volume 8. URL: https://www.law.cornell.edu/cfr/text/21/868.5440 (Accessed November 9, 2026).
  • U.S. Food and Drug Administration. AccessGUDID Database: OxyGo Portable Oxygen Concentrators and Replacement Accessories (DI / UDI Records). U.S. National Library of Medicine. URL: https://accessgudid.nlm.nih.gov/ (Accessed November 9, 2026).
  • OxyGo LLC. OxyGo, OxyGo FIT, and OxyGo NEXT Technical Specifications and User Manuals. URL: https://www.oxygo.life (Accessed November 9, 2026).
  • Federal Aviation Administration. Advisory Circular AC 120-95A: Portable Oxygen Concentrators. U.S. Department of Transportation, Title 14 CFR § 121.574. URL: https://www.faa.gov (Accessed November 9, 2026).
  • Centers for Medicare & Medicaid Services. Local Coverage Determination (LCD): Oxygen and Oxygen Equipment (L33797 / HCPCS Codes E1390 and E1392). URL: https://www.cms.gov/medicare-coverage-database/ (Accessed November 9, 2026).

Follow CASRAI

Research-administration guidance, standards updates and independent tool reviews.

Ask CASRAI · free to try

Ask about OxyGo: Models, Specs, Battery Life and FDA Rules

2 free questions a day, no account.

An AI assistant for research: funder rules, compliance, methods and publishing. It links the sources behind its answers and labels answers that come from a web search.

Answers draw on CASRAI's guides and dictionary plus the federal and funder documents we index: Federal Register, Grants.gov, Regulations.gov and UKRI.

Works on this site and inside Claude, Cursor and the AI tools you already use.

Everything CASRAI publishes — this page, the dictionary, the guides and the news — stays open to read, with no account and no card.

Referenced across the research world

University of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logoUniversity of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logo
  • University of Cambridge logo
  • Columbia University logo
  • Crossref logo
  • University of Edinburgh logo
  • Harvard University logo
  • University of Oxford logo
  • Princeton University logo
  • Stanford School of Medicine logo
  • University College London logo
  • ORCID logo

View CASRAI adoption →