Skip to main content
v2026.11,986 entries · CC-BY 4.0

Pentane SDS: Hazards, Flash Point, Storage and Disposal

Pentane SDS explained section by section: GHS hazards, flash point, storage and disposal, and where supplier sheets differ.

Written and maintained by CASRAI Editorial Board

Published

On this page

A pentane safety data sheet (SDS) describes a highly flammable, volatile hydrocarbon solvent: n-pentane, CAS 109-66-0, carries the signal word Danger, is classed as a flammable liquid (hazard statement H225 on most supplier sheets), and is also labelled for aspiration hazard (H304) and drowsiness or dizziness (H336). The sheets agree on the hazards but not on every number, and one widely circulated sheet titled “Pentane” is for a different substance altogether.

This page reads a pentane SDS section by section, shows where the ILO/WHO International Chemical Safety Card, the ECHA notifications aggregated by PubChem and three real supplier sheets disagree, and sets out the storage, spill, disposal and protective-equipment content they share. It is general information; the sheet that ships with the bottle in your lab is the document that governs your handling.

What a pentane SDS contains

In the United States, the Hazard Communication Standard requires the chemical manufacturer or importer to supply a sheet in English with sixteen numbered sections in a fixed order: identification; hazard(s) identification; composition/information on ingredients; first-aid measures; fire-fighting measures; accidental release measures; handling and storage; exposure controls/personal protection; physical and chemical properties; stability and reactivity; toxicological information; ecological information; disposal considerations; transport information; regulatory information; and other information, including the date of preparation or last revision (29 CFR 1910.1200(g)(2)). The same standard notes that OSHA does not enforce the content of sections 12 through 15, because those areas are outside its jurisdiction. European sheets use the same sixteen headings under REACH and the CLP Regulation.

For pentane, the sections that decide daily practice are these:

  • Section 1 and 3 (identity). The CAS number is the check that matters. n-Pentane is 109-66-0, with EC number 203-692-4 and UN number 1265 on the sheets and card read for this page.
  • Section 2 (hazards). The pictograms, signal word, H-statements and P-statements. Section “Classification” below shows how these differ between suppliers.
  • Sections 5 to 7 (fire, spills, handling and storage). Where pentane’s flash point of about −49 °C drives almost every instruction.
  • Section 8 (exposure controls and PPE). Occupational exposure limits, ventilation and protective equipment.
  • Sections 13 and 14 (disposal and transport). Waste routes and the UN 1265 shipping description.

Is it “pentane” or n-pentane? Check the CAS number first

Sheets are titled “Pentane” and “n-Pentane” interchangeably, but a title is not an identity. The Air Liquide Malaysia sheet titled simply “Pentane” (reference ALM/SDS/133, revision date 23 June 2021) lists CAS 463-82-1 and EC 207-343-7, a different registry entry from n-pentane’s 109-66-0. It describes a gas at 20 °C with a boiling point of 9.5 °C, classified under the CLP Regulation as a flammable gas (H220), a gas under pressure (H280) and chronically hazardous to the aquatic environment (H411), shipped under UN 2044 as class 2.1, with test-gas and calibration-gas uses listed. Its guidance on leaks, cylinders and gas detectors does not carry over to a bottle of liquid solvent.

Labs buying a liquid solvent should therefore confirm 109-66-0 in section 1 or 3, and treat a sheet with a different CAS number as describing a different material. The Portuguese national entry quoted on one supplier sheet is labelled “Pentano, todos os isómeros” (pentane, all isomers), a reminder that regulators sometimes group the isomers in one limit while sheets for individual products do not.

Pentane GHS classification: why suppliers differ

The Globally Harmonized System (GHS) label elements on a pentane sheet are consistent in outline. The International Chemical Safety Card for n-pentane (ICSC 0534, April 2014 revision) lists the flame, exclamation mark and health hazard pictograms, the signal word DANGER, and the statements “highly flammable liquid and vapour”, “may cause drowsiness or dizziness”, “may be fatal if swallowed and enters airways” and “toxic to aquatic life”. The detail varies because classification is a decision each supplier takes for its own product and notifies to a regulator.

PubChem aggregates the notifications made to the European Chemicals Agency’s Classification and Labelling Inventory for pentane: 1,378 reports from 43 notifications. PubChem notes that information may vary between notifications depending on impurities, additives and other factors. Its figures for the hazard statements notified by more than 10% of companies that provided hazard codes are:

Hazard statement Wording Share of ECHA reports
H225 Highly flammable liquid and vapour 82.8%
H224 Extremely flammable liquid and vapour 16.4%
H304 May be fatal if swallowed and enters airways 99.2%
H336 May cause drowsiness or dizziness 99.1%
H411 Toxic to aquatic life with long lasting effects 99.2%

The same PubChem entry shows that 11 of the 1,378 reports state that the chemical does not meet GHS hazard criteria, and other notifier entries add eye irritation (H320) and respiratory irritation (H335), and, in one case, acute aquatic toxicity (H401) instead of H411. In practice that means two bottles of pentane from two suppliers can legitimately carry a different flammability category or one more or fewer health statements.

Real supplier sheets show the same spread. A US-format sheet for n-pentane (Columbus Chemical, product 3933, revised 26 August 2024) lists flammable liquids Category 2 (H225), aspiration hazard Category 1 (H304) and specific target organ toxicity from single exposure Category 3 (H336), with no H411 among its label statements. A European-format sheet for n-pentane AGR (Labbox, version 1.4, revised 15 June 2026) lists the same three plus H411 (hazardous to the aquatic environment, chronic Category 2), with four pictograms (GHS02, GHS08, GHS07, GHS09). The comparison table in the data section below sets these side by side with the card and the “Pentane” gas sheet.

Reading the precautionary statements

The P-statements on the sheets are consistent where it matters. The Columbus sheet’s prevention list includes P210 (keep away from heat, hot surfaces, sparks, open flames and other ignition sources, no smoking), P233 (keep the container tightly closed), P240 (ground and bond container and receiving equipment), P241 (use explosion-proof electrical, ventilating and lighting equipment), P242 (use only non-sparking tools), P243 (prevent static discharges), P280 (protective gloves, clothing, eye and face protection) and P235 (keep cool). Its response list includes P331, do not induce vomiting, and its storage and disposal statements are P403+P233, P405 and P501. PubChem’s aggregate list for the majority classification carries the same core codes, adding P261, P271 and, where H411 is notified, P273 and P391.

Pentane flash point and fire hazards

The flash point is the figure that makes pentane a fire-control problem rather than a routine solvent. The card gives −49 °C (closed cup), an auto-ignition temperature of 260 °C and explosive limits of 1.5 to 7.8% by volume in air, with a boiling point of 36 °C and a vapour pressure of 53.3 kPa at 18.5 °C. The Columbus sheet also gives −49 °C and 36 °C but “no data available” for auto-ignition and the flammability limits. The Labbox sheet gives −40 °C, 285 °C and 1.4 to 8% by volume, with a boiling point of 36.06 °C.

All of these values lie far below room temperature: a flash point below 0 °C means ignitable vapour is present at any normal laboratory temperature, and with a boiling point of 36 °C a warm room or a hand-warmed flask can push a pentane container into rapid evaporation. The card adds three behaviours worth noting at the bench: the vapour is heavier than air (relative vapour density 2.5), travels along the ground and can accumulate in low spaces; heating can raise pressure to the point of bursting; and flowing liquid can build up static charge, which is why grounding appears in every sheet. For the related solvent boiling-point and volatility numbers, see our pentane boiling point guide.

Fire-fighting media on the sheets

The card lists powder, carbon dioxide, alcohol-resistant foam and water spray, and advises keeping drums and containers cool with water spray. The Columbus sheet’s response statement P370+P378 names carbon dioxide, dry chemical or foam. Use the extinguishing instruction on the sheet that matches your product.

Storage and incompatibilities for pentane

The card’s storage line is short and specific: keep fireproof, cool and tightly closed; separate from strong oxidants; store in an area without drain or sewer access; and provide containment for fire-extinguishing effluent. The Columbus sheet adds that containers should be kept in a dry, cool, well-ventilated place, labelled, away from combustible materials, in an area equipped with sprinklers, and locked up. The Labbox sheet gives a storage temperature below 50 °C, tells the user to keep only the original container, and names sources of ignition as the incompatible material for storage.

The reactivity entries line up with the card, which states that pentane reacts with strong oxidants such as peroxides, nitrates and perchlorates, and attacks some plastics, rubbers and coatings. The Columbus sheet lists strong oxidizing agents as the incompatible material. The card’s prevention column also says not to use compressed air for filling or discharging and to use non-sparking hand tools and explosion-proof electrical equipment and lighting.

Spills, waste and disposal

For a spill, the card’s disposal instructions run in a clear order: evacuate the danger area and consult an expert; remove all ignition sources; wear a filter respirator suited to organic gases and low-boiling vapours; prevent release to the environment and do not wash into sewers; collect liquid in sealable containers where possible; and absorb the remainder with dry sand or an inert absorbent. The Columbus sheet uses the same approach: keep out of drains, sewers, ditches and waterways, absorb with earth, sand or other non-combustible material, and transfer to labelled containers, with a note to take precautions against static discharge.

On disposal itself, the sheets defer to local rules. The card says to dispose of the residue according to local regulations; the Columbus sheet says not to release the product to the environment and to dispose of it in accordance with local regulations and environmental legislation; the Labbox sheet says disposal must follow official regulations; and the P501 statement tells the user to dispose of contents and container at an approved waste disposal plant. No sheet read for this page gives a lab-level treatment, and none treats pentane as drain-disposable. For disposal of comparable flammable hydrocarbon solvents see our guides to heptane and cyclohexane.

Protective equipment and exposure limits

The card recommends protective gloves for skin protection, safety spectacles for eyes and ventilation, local exhaust or breathing protection for inhalation, and notes that pentane defats the skin with repeated contact. The Labbox sheet names chemical-protective gloves to EN 374, protective clothing to EN 14605 or EN 13034 and an AX (brown) filter for respiratory protection. The Columbus sheet specifies impervious gloves and states that no respiratory protection is needed under normal use conditions provided exposure limits are not exceeded. The card also warns that high airborne concentrations cause oxygen deficiency and advises checking oxygen levels before entering the area.

Occupational exposure limits vary by jurisdiction, and the sheets show it. The card lists a TLV of 1000 ppm as a time-weighted average and an EU occupational exposure limit of 3000 mg/m³ (1000 ppm). The Labbox sheet repeats the EU indicative limit and lists French, German and Spanish values of 3000 mg/m³ (1000 ppm), an Italian value of 2000 mg/m³ (667 ppm) and a United Kingdom workplace exposure limit of 1800 mg/m³ (600 ppm) with a short-term value of 5400 mg/m³ (1800 ppm). Check the limit that applies where you work.

Where the sheets disagree: a pre-use checklist

Each point below is one that differs between the sources read for this page, together with what to check on the sheet you are holding.

  • Identity. CAS 109-66-0 means n-pentane; another CAS number means another material (the Air Liquide “Pentane” sheet is for CAS 463-82-1).
  • Flammable-liquid category. ECHA notifications split between H225 (Category 2 wording, “highly flammable”) and H224 (“extremely flammable”); the Columbus and Labbox sheets both state Category 2.
  • Flash point. −49 °C on the card and the Columbus sheet, −40 °C on the Labbox sheet. Use your own sheet’s value in the risk assessment, and treat anything below 0 °C as equivalent for ignition-control purposes.
  • Auto-ignition and explosive limits. 260 °C versus 285 °C versus “no data”, and 1.5 to 7.8% versus 1.4 to 8% by volume.
  • Aquatic hazard. H411 appears on the Labbox sheet and in 99.2% of ECHA reports, but not among the Columbus label statements.
  • Transport packing group. The card lists packing group I; both the Columbus (US DOT) and Labbox (ADR) sheets list packing group II under UN 1265, class 3.
  • Revision date. The sheets read here range from 2021 to 2026, and the card from April 2014. A supplier sheet that is several years old may predate a reclassification.

Common misunderstandings

“All pentane SDSs are the same document”

They share a core of hazards, but classification, limits and physical values are set by each supplier, regional rules and the sheet’s revision date, as the table of differences in the data section shows. The regional format also changes: the Columbus sheet is prepared to the US Hazard Communication Standard and the Labbox sheet to the REACH Regulation as amended by Regulation (EU) 2020/878.

“An SDS only matters in an emergency”

The sheet is designed as a working reference: sections 7 and 8 set out how pentane is stored and handled, and section 9 supplies the numbers a risk assessment uses. The US standard requires employers to keep a sheet in the workplace for each hazardous chemical they use.

“Pentane is only a fire problem”

Fire dominates the sheets, but the card also lists aspiration hazard (do not induce vomiting after swallowing), central nervous system depression at high vapour concentrations, skin defatting and toxicity to aquatic organisms. Related solvents have similar profiles with different numbers, for example toluene and ethyl acetate.

Sources

Data: Pentane safety data: how a reference card and three supplier sheets compare

Side-by-side comparison of identity, classification, flash point, auto-ignition, explosive limits, transport entry and exposure limits for pentane as printed on the ILO/WHO International Chemical Safety Card 0534 and on three supplier safety data sheets (Columbus Chemical, Labbox, Air Liquide Malaysia), compiled from each document as published. The Air Liquide sheet titled Pentane describes a different substance (CAS 463-82-1).

Period covered: Sheet revision dates 2014-2026.

Pentane safety data: how a reference card and three supplier sheets compare
PropertyICSC 0534 n-Pentane (ILO/WHO)Columbus Chemical n-Pentane 3933Labbox n-Pentane AGRAir Liquide Malaysia 'Pentane' ALM/SDS/133
CAS number109-66-0109-66-0109-66-0463-82-1
Document dateApril 2014 card revisionRevision date 26 Aug 2024Revision date 15 Jun 2026Revision date 23 Jun 2021
Physical stateColourless liquidLiquid (boiling point 36 C)Liquid (boiling point 36.06 C)Gas at 20 C (boiling point 9.5 C)
Classification statementsHighly flammable liquid and vapour; drowsiness or dizziness; may be fatal if swallowed and enters airways; toxic to aquatic lifeH225, H304, H336H225, H304, H336, H411H220, H280, H411
Flammable categoryHighly flammable liquidFlammable liquids Category 2Flammable liquids Category 2Flammable gases Category 1
Flash point (C)-49 (closed cup)-49-40Not applicable for gases
Auto-ignition temperature (C)260No data available285450
Explosive limits in air (vol %)1.5 - 7.8No data available1.4 - 81.3 - 7.5
Transport entryUN 1265, class 3, packing group IUN1265 Pentanes, class 3, packing group II (DOT)UN 1265 Pentanes, class 3, packing group II (ADR)UN 2044, class 2.1 (flammable gas)
Occupational limit as printedTLV 1000 ppm TWA; EU-OEL 3000 mg/m3 (1000 ppm)ACGIH TLV 1000 ppm TWAEU IOEL 1000 ppm; UK WEL 600 ppm (1800 mg/m3); Italy 667 ppm (2000 mg/m3)ACGIH TWA 1000 ppm
Sheet prepared underNot applicable (card)US OSHA Hazard Communication Standard (29 CFR 1910.1200)REACH Regulation (EC) 1907/2006 as amended by (EU) 2020/878Regulation (EU) 2015/830

Sources

Compiled by CASRAI from the sources above. Free to reuse under CC BY 4.0 with attribution.

Follow CASRAI

Research-administration guidance, standards updates and independent tool reviews.

Ask CASRAI · full access

Ask about Pentane SDS: Hazards, Flash Point, Storage and Disposal

Full access: large monthly usage, up to 10 source passages behind each answer, and MCP and API access for Claude Code, Codex and other CLIs. Cancel any time.

An AI assistant for research: funder rules, compliance, methods and publishing. It links the sources behind its answers and labels answers that come from a web search.

Answers draw on CASRAI's guides and dictionary plus the federal and funder documents we index: Federal Register, Grants.gov, Regulations.gov and UKRI.

Works on this site and inside Claude, Cursor and the AI tools you already use.

Everything CASRAI publishes — this page, the dictionary, the guides and the news — stays open to read, with no account and no card.

Referenced across the research world

University of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logoUniversity of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logo
  • University of Cambridge logo
  • Columbia University logo
  • Crossref logo
  • University of Edinburgh logo
  • Harvard University logo
  • University of Oxford logo
  • Princeton University logo
  • Stanford School of Medicine logo
  • University College London logo
  • ORCID logo

View CASRAI adoption →