Sterile Pipette: Types, Sizes and Handling

Compare sterile bulb transfer and serological pipettes, with manufacturer specifications, packaging differences and general handling limits.

Written and maintained by CASRAI Editorial Board

Published · Last updated

On this page

A sterile pipette is a liquid-transfer consumable supplied sterile for its stated laboratory use. The term includes flexible bulb transfer pipettes and graduated serological pipettes used with a controller. Sterility describes the supplied product; its volume markings, packaging format and permitted applications still need separate checks in the manufacturer’s instructions.

This page describes products and general use; it is not medical advice.

Who uses it: medical laboratory professionals use sterile transfer pipettes for specified sample-transfer tasks; trained research laboratory personnel use sterile serological pipettes within their manufacturer’s intended use. The distinction matters: SARSTEDT describes diagnostic specimen transfer, while Eppendorf’s Serological Pipets instructions exclude diagnostic and therapeutic applications.

What a sterile pipette is

“Sterile pipette” names a product attribute across more than one pipette design. A one-piece transfer dropper has its own squeeze bulb. A serological pipette is a graduated tube connected to a separate manual or electronic controller. Both have sterile versions, but they move liquid differently and carry different measurement specifications. The wider laboratory pipette overview explains the surrounding instrument categories.

The useful distinction is between the product’s identity and its individual claims. In its transfer-pipette instructions, SARSTEDT lists sterile and nonsterile options within the same family. Eppendorf separately lists sterility, freedom from specified contaminants and noncytotoxicity for its serological products. Those separate declarations should remain separate when describing a product: a sterile label alone is not a statement about graduation accuracy, chemical resistance or every purity characteristic.

Intended use is another independent field. SARSTEDT’s instructions describe moving diagnostic sample material between vessels, including urine, blood, serum and plasma. Eppendorf describes trained users in life-science, industrial and chemistry laboratories, with a research-only restriction. Calling both products sterile does not erase that difference or establish that one is an interchangeable substitute for the other.

How sterile pipettes work and are built

Integrated-bulb transfer pipettes

SARSTEDT’s transfer pipettes combine the suction bulb with the liquid-transfer stem. Its instructions identify the material as low-density polyethylene, or LD-PE. Compressing and releasing the bulb controls aspiration; compressing it again releases the liquid. There is no separate pipette controller to attach. The manufacturer’s variants differ in suction volume, length, drop size and whether a graduation is present.

The graduation on these products is an approximate reference. SARSTEDT states a ±15% accuracy for the graduation and drop size, and describes the products as intended for undefined liquid quantities. Its instructions direct users needing exact volumes to a piston pipette with an appropriate tip. Sterile packaging does not change that measurement restriction. For more detail on the bulb format, see transfer pipette types and volume markings.

Controller-operated serological pipettes

Eppendorf’s Serological Pipets use a polystyrene tube and a polyethylene/polyester filter. The illustrated parts include the outlet, graduated scale, zero point, negative graduation, nominal volume and aspiration area. Manual or electronic controllers provide the aspiration and dispensing action. These single-use pipettes are calibrated for blow-out delivery, so their delivery convention differs from an approximate bulb dropper.

The controller is a separate device with its own instructions. For example, INTEGRA’s PIPETBOY GENIUS manual specifies aqueous solutions and glass or plastic pipets in a stated volume range. A pipette’s suitability for a liquid and a controller’s suitability for that liquid are separate questions. Neither the sterile wrapper nor the tube material replaces the operating limits of the assembled system.

Types and packaging variants

Individual wrapping and sterility are different descriptors. SARSTEDT’s transfer-pipette IFU describes both individual sterile packs and sterile packs of ten. INTEGRA’s controller manual lists sterile serological accessories in individual wrappers and bags containing multiple pipettes. A multipack can therefore be supplied sterile; its pack count does not make it a nonsterile product.

Type or variant Stated use or role Key difference Source
Individually packed sterile transfer pipette Transfer of diagnostic sample material, including material for microbial analysis Integrated bulb; one pipette in the sterile pack SARSTEDT transfer IFU, English pp. 4–5
Ten-piece sterile transfer pack The same IFU-defined transfer role Multiple bulb pipettes share one sterile pack SARSTEDT transfer IFU, English p. 4
Individually wrapped sterile serological pipette Consumable for a pipette controller INTEGRA lists polystyrene accessories with individual wrapping PIPETBOY GENIUS manual, section 7
Bagged sterile serological pipettes Alternative accessory packaging for the controller INTEGRA lists 25 per bag through its 50 mL size and ten per bag for 100 mL PIPETBOY GENIUS manual, section 7

These are documented examples, rather than a universal packaging scheme. Keep the wrapper description attached to the named product. In particular, an instruction to use a pipette after opening its packaging does not establish a storage period for unused pipettes in an opened multipack. Eppendorf directs users to use its serological pipettes immediately after opening to protect against contamination.

Sizes and specifications that matter

Read nominal volume, marked range, graduation increment and accuracy as different specifications. A nominal size identifies the product, while the marked range tells you which volumes appear on its scale. The increment is the gap between adjacent markings. Accuracy is a separate manufacturer specification, not a value inferred from the number of printed lines.

SARSTEDT illustrates the distinction with two 3.5 mL transfer-pipette families. One has markings from 0.5 to 3 mL in 0.5 mL steps; another has markings from 0.25 to 1 mL in 0.25 mL steps. Both have the same nominal volume, but their scales cover different ranges. Neither scale converts the product into an exact-volume instrument.

Eppendorf’s serological range lists nominal sizes of 1, 2, 5, 10, 25 and 50 mL, each with its own increment, length and accuracy entry. For example, its 1 mL pipette has a 0.01 mL graduation increment but a stated accuracy of ±0.02 mL. On its 10 mL size, the increment is 0.1 mL and the stated accuracy is ±0.2 mL. The smallest readable division and the accuracy specification are therefore different even on a graduated measuring pipette.

The data table below compiles selected IFU values across the SARSTEDT transfer and Eppendorf serological families. It compares nominal size, scale increment and length; it does not rank their accuracy or imply equivalent intended uses. SARSTEDT family entries include sterile options, so the supplied package must still identify the sterile variant.

How to choose from the manufacturer’s stated criteria

Start with intended use and required measurement, then check the material and operating instructions. The following criteria come directly from the cited IFUs and CDC guidance. They are product-document checks, rather than recommendations based on a laboratory’s size, purchasing budget or presumed workflow.

  • Required measurement: SARSTEDT specifies its transfer pipettes for quantities that do not need to be exact. Where exact volumes are required, its IFU directs users to a piston pipette and suitable tip. A sterile bulb dropper does not remove the need for that distinction.
  • Permitted application: Eppendorf’s research-only restriction excludes diagnostic and therapeutic uses. Match the named product’s intended use, even when another sterile product of similar appearance has a different scope.
  • Liquid compatibility: Eppendorf instructs users to check chemical resistance before handling organic solvents or aggressive chemicals. Its table classes acetone and chloroform as unsuitable for that serological product. Do not generalize a plastic’s appearance into a compatibility claim.
  • Controller limits: INTEGRA specifies 1–100 mL glass or plastic pipets and aqueous solutions for PIPETBOY GENIUS. Eppendorf also requires users to read the controller manual. These limits belong to the named system, rather than every controller.
  • Package condition and expiry: SARSTEDT’s label key includes a damaged-package prohibition, and its warnings exclude expired transfer pipettes. Eppendorf locates expiry information on the box label and blister packaging.

A useful reading sequence is therefore application, measurement requirement, material compatibility, controller requirements, and package status. This sequence brings together the manufacturers’ stated checks; it does not add a new certification or a clinical-use permission.

Safe use and handling basics

Use the instructions for the actual consumable and controller together. SARSTEDT requires personal protective equipment for diagnostic samples and hazardous materials. CDC’s diagnostic-laboratory guidance prohibits mouth pipetting and requires mechanical pipetting devices. A sterile pipette is still laboratory equipment to be handled under the facility’s safety rules.

CDC also calls for gloves when handling hazardous material, replacement of contaminated or compromised gloves, and handwashing after hazardous work. Its guidance warns against touching the face with gloved hands and requires appropriate surface decontamination after work or spills. These practices address handling around the product; a manufacturer’s sterility claim does not replace them. The broader aseptic technique guide explains the surrounding laboratory practice.

For unopened SARSTEDT transfer pipettes, the IFU specifies room-temperature storage and includes label symbols for dry storage and protection from sunlight. Its label key also identifies ethylene oxide sterilization, sterile-barrier configurations and a prohibition on resterilization. Read the applicable package label alongside the IFU rather than assuming every symbol describes every product variant.

After use, SARSTEDT requires disposal under the facility’s rules and appropriate biohazard containers for contaminated transfer pipettes. The products are single-use, with a stated contamination risk on reuse. Eppendorf likewise describes its serological pipettes as single-use and explicitly says they are not autoclavable. Washing or autoclaving is not a permitted reuse route for that product.

Controller maintenance must remain separate. INTEGRA allows autoclaving of specified PIPETBOY GENIUS nose-piece components under its documented conditions and requires replacement of a wet or dirty filter. Those instructions apply to named reusable parts. They do not authorize autoclaving an attached single-use pipette, or establish a cleaning method for another manufacturer’s controller.

Common mistakes

Reading “sterile” as “precise”

SARSTEDT’s transfer IFU expressly separates approximate transfer from exact-volume pipetting. Eppendorf lists graduation and accuracy separately. Keep those distinctions in the product record: sterility concerns one property, while the intended measurement and its limits concern another.

Assuming every sterile pipette is individually wrapped

Both SARSTEDT and INTEGRA document sterile multipacks. Record the actual pack format rather than using “sterile” as shorthand for individual presentation. Similarly, the existence of a sealed bag does not establish sterility unless the product’s labeling identifies the sterile option.

Extending one purity claim to all products

Eppendorf separately declares sterility, specified contaminant exclusions and noncytotoxicity for its serological pipettes. Keep those statements attached to that product. Its IFU identifies lot details on the box and blister and describes available lot-specific certificates, providing a way to associate documentation with the supplied consumable.

Treating controller faults as a pipette-volume problem

INTEGRA’s troubleshooting table lists a damaged or incompletely inserted pipet, a damaged pipet mount, and a damaged or missing filter among causes of leakage. Its table also connects wet or dirty filters with operating problems. Investigate the named system using its manual; changing the nominal pipette size does not address those documented causes.

Confusing a sterile pipette with a sterile pipette tip

The bulb transfer and serological products described here are complete disposable pipettes. A piston pipette instead takes a suitable tip, the combination SARSTEDT specifies for exact-volume work. The separate pipette tip selection guide covers that consumable category.

Sources

Data: Selected sterile pipette family specifications

Original compilation of nominal volume, graduation increment and length from the SARSTEDT transfer-pipette IFU and Eppendorf Serological Pipets IFU. Transfer-family entries have sterile options; package labeling identifies the supplied variant. Values describe different product families and do not establish interchangeable uses or equal accuracy.

Selected sterile pipette family specifications
Manufacturer and pipette familyNominal volume (mL)Graduation increment (mL)Length (mm)Source location
SARSTEDT transfer 86.1171 family, sterile option3.50.5155SARSTEDT IFU, English p. 4
SARSTEDT transfer 86.1172 family, sterile option3.50.25156SARSTEDT IFU, English p. 4
Eppendorf Serological Pipet, 1 mL10.01277Eppendorf IFU, section 2.2
Eppendorf Serological Pipet, 10 mL100.1338Eppendorf IFU, section 2.2
Eppendorf Serological Pipet, 50 mL500.5343Eppendorf IFU, section 2.2

Sources

Compiled by CASRAI from the sources above. Free to reuse under CC BY 4.0 with attribution.

Follow CASRAI

Research-administration guidance, standards updates and independent tool reviews.

Ask CASRAI · free to try

Ask about Sterile Pipette: Types, Sizes and Handling

2 free questions a day, no account.

An AI assistant for research: funder rules, compliance, methods and publishing. It links the sources behind its answers and labels answers that come from a web search.

Answers draw on CASRAI's guides and dictionary plus the federal and funder documents we index: Federal Register, Grants.gov, Regulations.gov and UKRI.

Works on this site and inside Claude, Cursor and the AI tools you already use.

Everything CASRAI publishes — this page, the dictionary, the guides and the news — stays open to read, with no account and no card.

Referenced across the research world

University of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logoUniversity of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logo
  • University of Cambridge logo
  • Columbia University logo
  • Crossref logo
  • University of Edinburgh logo
  • Harvard University logo
  • University of Oxford logo
  • Princeton University logo
  • Stanford School of Medicine logo
  • University College London logo
  • ORCID logo

View CASRAI adoption →