PleurX Drainage Kit: What Is in the Box and What to Check Before You Order

What BD instructions for use list in the PleurX lockable drainage line kit and procedure pack, and what to check before ordering one.

Written and maintained by CASRAI Editorial Board

Published · Last updated

On this page

Short answer: a PleurX drainage kit is the single-use accessory set used with a PleurX catheter, which is a separate device. This page lists what BD’s instructions for use (IFU) say the lockable drainage line kit and the procedure pack contain, so a buyer or stock manager can match a catalogue number to its contents. It is general product information, not medical advice and not a procedure guide; a doctor or nurse decides how and when the catheter system is used.

Purpose and setting

People search “pleurx drainage kit”, “pleurx catheter” and “pleurx drainage” for the same system. The BD PleurX system is labelled for intermittent drainage of the pleural or peritoneal cavity. The manufacturer’s pleural catheter page describes the pleural system as indicated for “intermittent, long term drainage of symptomatic, recurrent, pleural effusion”. For how the peritoneal catheter is classified by the FDA (the PleurX Peritoneal Catheter System, 510(k) K201155), see peritoneal drain: indwelling catheter and FDA classification. This page does not repeat that and does not cover use steps.

PleurX catheter versus drainage kit

The catheter is the indwelling device placed by a clinician. The kits are accessories. BD’s lockable drainage line kit IFU states it is “designed to be used exclusively with the PleurX Pleural or Peritoneal Catheter” and is indicated for use only with the PleurX catheter for intermittent drainage. BD lists some drainage kits with a vacuum bottle and others without, so the catalogue number matters. Related plain-language device pages: what is a chest tube and Wayne pneumothorax kit set types and contents.

Checklist table: what the IFUs list

Item Lockable Drainage Line Kit (cat. 50-7265) Procedure Pack (cat. 50-7290) Notes
Drainage line with lockable access tip 1 Not listed Line component, only in the line kit
5-in-1 drainage line adapter 1 Not listed Only in the line kit
Catheter valve cap 1 1 Listed in both
Blue emergency clamp 1 1 (blue emergency slide clamp) Listed in both
Alcohol pads 4 3 The Procedure Pack IFU warns alcohol pads are flammable
Gloves 1 pair 1 pair Listed in both
Foam catheter pad 1 1 Listed in both
Gauze pads, 4 in x 4 in (10.2 x 10.2 cm) 4 4 Listed in both
Self-adhesive dressing 1 1 Listed in both

Sources: BD PleurX Lockable Drainage Line Kit IFU (doc. 12279870, 2012-06) and BD PleurX Procedure Pack IFU (doc. 12281367, 2012-09), checked 2026-11-03. Counts are those printed in each IFU for that catalogue number; a newer revision or another region may differ. The Procedure Pack IFU says the pack is indicated for dressing of the PleurX catheter and exit site.

Other catalogue items on the manufacturer’s family page

BD’s PleurX pleural catheter system page (en-ca regional page, checked 2026-11-03) lists, among others: drainage kit with 1,000 mL vacuum bottle (50-7510); drainage kit with 500 mL vacuum bottle (50-7500B); vacuum bottles (50-7210, 50-7205B); starter kit with four 1,000 mL drainage kits (50-0071); catheter access kit (50-7280); pleural catheter kit (50-7000B); emergency valve replacement kit (50-7270); lockable drainage line (50-7245); supplemental insertion kit (50-7262); replacement valve cap (50-7235). Catalogue numbers and availability vary by region, so confirm against the current BD listing for your country.

What to verify before ordering

  • Catalogue number against the IFU. Items with similar names differ: the line kit contains the drainage line, the procedure pack contains dressing supplies, and bottle kits add a vacuum bottle.
  • Prescription status. The line kit IFU is marked Rx only.
  • Single use and sterility. The line kit IFU states it is “for single use only” and that re-use may cause a nonfunctional product or cross contamination. The Procedure Pack IFU states the pack is sterilized, must not be re-sterilized, and says “Do not use if package is damaged”.
  • Latex and phthalates. Both IFUs state the product and packaging do not contain natural rubber latex, and that the product contains phthalates (DEHP).
  • Current IFU. Ask the supplier for the current IFU revision for the exact catalogue number.

What varies by facility type

The IFUs do not give separate contents for hospitals, clinics, home care or other settings, so this page does not either. The kit is the same item wherever it is stocked; who may use it is a clinical and local-policy question. The Procedure Pack IFU states users “should have been trained by a doctor or nurse”.

Storage, expiry and restocking

Neither IFU gives a storage temperature or a shelf-life figure. Read storage and expiry information on the carton label of the lot you receive, and follow the facility’s own stock-rotation rules. Because the contents are single use and sterile, an opened or damaged package is not a restocking candidate under the Procedure Pack IFU wording above.

Standards and rules that apply

  • Prescription-only labelling (“Rx Only”) appears on the line kit IFU.
  • FDA regulatory status of the peritoneal catheter system (510(k) K201155) is covered at peritoneal drain and FDA classification.

FAQ

What is in a PleurX drainage kit?

It depends on the catalogue number. The lockable drainage line kit (50-7265) lists a drainage line with lockable access tip, a 5-in-1 adapter, a valve cap, an emergency clamp, alcohol pads, gloves, a foam pad, gauze pads and a self-adhesive dressing. Kits that include a vacuum bottle are listed separately by BD.

Is a PleurX catheter the same as a drainage kit?

No. The catheter is the indwelling device; the drainage kit and procedure pack are single-use accessories labelled for use with it.

Can a PleurX drainage kit be reused?

No. The line kit IFU says it is for single use only, and the Procedure Pack IFU says the pack must not be re-sterilized.

Does it contain latex?

The IFUs state the product and packaging do not contain natural rubber latex. They also state the product contains phthalates (DEHP).

Sources

Follow CASRAI

Research-administration guidance, standards updates and independent tool reviews.

Ask CASRAI · free to try

Ask about PleurX Drainage Kit: What Is in the Box and What to Check Before You Order

2 free questions a day, no account.

An AI assistant for research: funder rules, compliance, methods and publishing. It links the sources behind its answers and labels answers that come from a web search.

Answers draw on CASRAI's guides and dictionary plus the federal and funder documents we index: Federal Register, Grants.gov, Regulations.gov and UKRI.

Works on this site and inside Claude, Cursor and the AI tools you already use.

Everything CASRAI publishes — this page, the dictionary, the guides and the news — stays open to read, with no account and no card.

Referenced across the research world

University of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logoUniversity of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logo
  • University of Cambridge logo
  • Columbia University logo
  • Crossref logo
  • University of Edinburgh logo
  • Harvard University logo
  • University of Oxford logo
  • Princeton University logo
  • Stanford School of Medicine logo
  • University College London logo
  • ORCID logo

View CASRAI adoption →