Written and maintained by CASRAI Editorial Board
Published · Last updated
On this page
Potts-Smith forceps are hand-held, nonpowered surgical forceps sold in tissue and dressing versions, with lengths in FDA device records from 178 mm to 14 in. This page explains what the name covers, how the two versions differ in manufacturer listings, which lengths and variants FDA device records list, and how the device is regulated.
This page describes products and general use; it is not medical advice.
Who uses this page: clinic staff, buyers and students who need to identify a Potts-Smith forceps listing and understand what the name does and does not tell them.
What Potts-Smith forceps are
Potts-Smith is a pattern name for a manual forceps. Manufacturer records in the FDA Global UDI Database list the pattern as “Potts-Smith Tissue” forceps (described with “1 x 2 teeth”) and as “Potts-Smith Dressing” forceps (described as serrated). The name is a pattern label used by several manufacturers, not a single product, so two items sold as Potts-Smith forceps can differ in tip, length, material and coating.
The pattern is different from Potts scissors, which are a cutting instrument; the two share only part of a name.
How they are built
The FDA UDI records and one retailer listing describe these features, which vary by manufacturer and item:
- Tip pattern. Tissue versions are described with 1 x 2 teeth. Dressing versions are described as serrated, and some as ebonized serrated.
- Tungsten carbide (TC). Many Sontec records and some Aspen Surgical and Geister records name tungsten carbide; Sontec items are also described as “serrated tip” or “dust tip”.
- Stop pin. Six Sontec records describe a stop pin. A McKesson catalog listing for a Sklar Potts-Smith forceps (8-1/4 in, 1 x 2 teeth) describes a stop peg that limits how far the jaws close, so that tissue is not crushed.
- Insulated coating. Four Sontec records describe a blue electro-coated, insulated version in straight and curved forms. The same retailer listing describes an insulated coating version for electrosurgery.
- Other options. Records also list a DeBakey handle and a version with a round dissector end.
Tissue and dressing types
The same Potts-Smith name appears on both types, and one product can be labelled differently across catalogs: the McKesson listing above carries the application category “Dressing Forceps” even though the item is described as 1 x 2 teeth. Check the tip description, not the pattern name alone.
| Type (as named in FDA UDI records) | Tip as listed | FDA UDI records (of 56) |
|---|---|---|
| Potts-Smith Tissue | 1 x 2 teeth; some tungsten carbide, serrated or dust tips | 28 (Aspen Surgical 13, Sontec 13, CooperSurgical 2) |
| Potts-Smith Dressing | Serrated; some ebonized serrated; one tungsten carbide with a dissector end | 15 (Aspen Surgical 11, Sontec 2, CooperSurgical 1, Geister 1) |
| Pattern name only | Tip described in the item name (TC, serrated, stop pin, insulated) | 13 (all Sontec) |
Lengths and variants listed in FDA records
The records are manufacturer submissions, so this table lists what is recorded, not every length that exists.
| Manufacturer (as recorded) | Type | Lengths listed |
|---|---|---|
| Aspen Surgical (Symmetry, Classic Plus) | Tissue | 7 1/8, 7 1/4, 8, 8 1/4, 9, 10, 12 and 14 in; tungsten carbide versions at 7, 8, 9 and 10 in |
| Aspen Surgical (Symmetry) | Dressing | 7, 7 1/4, 8, 9 3/4, 10, 12 and 14 in; plain, serrated and ebonized serrated versions |
| CooperSurgical | Tissue, 1 x 2 teeth | 178 mm and 208 mm |
| Geister | Dressing, tungsten carbide | 25.0 cm |
| Sontec Instruments | Tissue, dressing and unspecified | Not stated in the item descriptions; variants include tungsten carbide, dust tip, stop pin and insulated versions |
Regulatory class and reprocessing basics
The FDA records use product code GEN, “Forceps, General & Plastic Surgery” (27 records), or HTD, “Forceps” (28 records); one CooperSurgical record carries the gynecological biopsy forceps code HFB. FDA’s classification database lists GEN and HTD under 21 CFR 878.4800 as device class 1. That regulation covers a nonpowered, hand-held or hand-manipulated surgical instrument for general use and names forceps in its list. It classifies the device as Class I (general controls) and exempt from premarket notification (510(k)), subject to the limitations in 21 CFR 878.9 (checked 2026-10-30).
All 56 records mark the item as not single-use (reusable). 55 of 56 mark it as requiring sterilization before use; the Geister record marks it otherwise. The sterilization methods the records list are moist heat or steam sterilization (Aspen Surgical, CooperSurgical, Sontec) and dry heat sterilization (Sontec). Each record also states that the labeling does not contain MRI safety information. Follow the manufacturer’s instructions for use for the specific item. For general background, see the CASRAI sterilization technology guide.
Common mistakes
- Treating the pattern name as a specification. The name does not tell you the tip, length, material or coating; read the item description.
- Confusing them with Potts scissors. Same eponym, different instrument.
- Assuming tissue and dressing items are interchangeable. The records give different tip descriptions for the two types.
- Assuming the item is ready to use. 55 of the 56 records are marked for sterilization before use.
- Assuming an item is insulated. Only items described as insulated or electro-coated are listed that way; four Sontec records carry that description.
Related forceps
For other named patterns and how forceps are grouped, see the medical forceps types guide, Lahey forceps, Bonney forceps and what a hemostat is. Related supplies are listed under forceps.
Sources
- FDA Global UDI Database via the openFDA UDI API, brand “potts-smith” with description “forceps”, 56 records, openFDA data last updated 2026-10-01, checked 2026-10-30: api.fda.gov/device/udi.json. The records are unvalidated manufacturer submissions.
- FDA device classification database, product codes GEN and HTD, checked 2026-10-30: api.fda.gov/device/classification.json.
- 21 CFR 878.4800, Manual surgical instrument for general use, checked 2026-10-30: Cornell LII.