What Are Lead Gloves? X-Ray Protective Gloves Explained

Lead (x ray) gloves shield hands from scattered radiation. See their FDA classification, construction, listed sizes, standards and handling basics.

Written and maintained by CASRAI Editorial Board

Published · Last updated

On this page

Lead gloves, in the medical sense, are hand-worn radiation shields. They are flexible gloves containing lead (or a lead-based layer) that a wearer uses near an X-ray beam to reduce the dose that scattered radiation delivers to the hands. People also search for them as x ray gloves. The FDA lists them as a regulated device type called a “radiation attenuating medical glove.”

This page describes products and general use; it is not medical advice.

What lead gloves are

A lead glove is protective clothing for staff who work in or near fluoroscopy or radiography. The FDA’s product classification for code OPH describes radiation attenuating medical gloves as gloves used during medical or surgical procedures involving radiation, to shield the wearer’s hands from scattered radiation. The same record says they offer some degree of protection from radiation exposure as well as protection from the transmission of infectious agents.

Who uses them: radiology and imaging staff and other personnel whose hands are near the field during fluoroscopy or radiography. The word “lead” also appears in unrelated products, such as gloves for handling lead-contaminated material or glove boxes; those are different items. For enclosed handling, see what a glove box is.

How lead gloves are built

The International Federation of Red Cross and Red Crescent Societies (IFRC) Items Catalogue lists a “lead gloves for X-ray protection” item built from several flexible lead-rubber or lead-vinyl layers, made from lead with natural rubber or vinyl. The listing says the set is supplied with inner gloves of 100% cotton, along with a multilingual user and maintenance manual, and that the product carries a CE mark. Many ordinary protective gloves are chosen for chemical or barrier performance; the lead layers are what make this glove a radiation device, which is why it is regulated separately from a plain nitrile or latex exam glove.

Regulatory identity and standards

Item What the record says Source
FDA device name and code Radiation Attenuating Medical Glove, product code OPH FDA product classification database
Device class Class 1, General Hospital review panel, 510(k) submission type FDA product classification database
Regulation number 21 CFR 880.6250 (the regulation for non-powdered patient examination gloves) FDA product classification database
Extra expectation for makers In addition to meeting the requirements for examination or surgeon’s gloves, manufacturers should have technical data showing that their attenuation claims meet the energy range of x-rays normally used in medical procedures FDA product classification database
Recognized consensus standard ASTM D7866-23, Standard Specification for Radiation Attenuating Protective Gloves FDA product classification page for OPH
Catalogue example standard EN 61331, protective devices against diagnostic medical X-radiation IFRC Items Catalogue

The regulation text in 21 CFR 880.6250 itself describes a disposable examination glove worn to prevent contamination between patient and examiner; the attenuation language comes from the FDA’s product classification entry, not from the regulation.

Sizes and specifications that matter

Specification Value listed Source
Standard size Medium (11-12) IFRC Items Catalogue
Length About 40-50 cm; the listing recommends a long shaft because it protects most of the lower arm IFRC Items Catalogue
Liner Inner glove, 100% cotton IFRC Items Catalogue
Lead equivalence The listing names the item as 0.5 mm Pb in its title and gives 0.35 mm in its specification field, so compare rated values against the product’s own label and test data rather than a catalogue line IFRC Items Catalogue (marked no longer updated, last updated 2018)

Lead gloves versus other hand protection

A lead glove is not interchangeable with an exam glove or a cut-resistant glove: the FDA’s statement ties the attenuation claim to the x-ray energy range used in medical procedures, so a rating is meaningful only within the conditions the manufacturer’s data covers. Unlike an apron, which covers the torso (see what an apron is), a glove protects only the hand and wrist area, and dose monitoring is a separate matter covered in how dosimetry badges work.

Safe use and handling basics

  • Storage: the IFRC listing gives storage below 45 °C, protected from direct light, not folded (it can be rolled).
  • Labelling: the listing says the label shows product name, size, CE mark and manufacturer address.
  • Follow the instructions for use: cleaning, disinfection and inspection steps come from the manufacturer’s manual supplied with the product.

Common mistakes

  • Folding the gloves for storage, which the catalogue listing says not to do.
  • Assuming a stated lead equivalence applies at any x-ray energy; the FDA expects the maker’s technical data to match the energy range normally used.
  • Confusing a medical radiation glove with an industrial “lead” glove or a glove box.

Frequently asked questions

What are x ray gloves?

“X ray gloves” is another name for lead or lead-vinyl gloves worn to reduce scatter dose to the hands. The FDA’s formal term is radiation attenuating medical glove.

Are lead gloves regulated by the FDA?

Yes. They are a Class 1 device under product code OPH, listed under 21 CFR 880.6250 in the FDA product classification database, checked 2026-10-31.

Which standard applies?

The FDA product classification page for OPH lists ASTM D7866-23 as a recognized consensus standard. The IFRC catalogue example cites EN 61331 and carries a CE mark.

Sources

  • FDA, Product Classification database, product code OPH, radiation attenuating medical glove (accessdata.fda.gov), checked 2026-10-31.
  • eCFR, 21 CFR 880.6250 (ecfr.gov), checked 2026-10-31.
  • IFRC Items Catalogue, “Gloves, lead, for X-ray protection” (itemscatalogue.redcross.int), checked 2026-10-31.

Follow CASRAI

Research-administration guidance, standards updates and independent tool reviews.

Ask CASRAI · free to try

Ask about What Are Lead Gloves? X-Ray Protective Gloves Explained

2 free questions a day, no account.

An AI assistant for research: funder rules, compliance, methods and publishing. It links the sources behind its answers and labels answers that come from a web search.

Answers draw on CASRAI's guides and dictionary plus the federal and funder documents we index: Federal Register, Grants.gov, Regulations.gov and UKRI.

Works on this site and inside Claude, Cursor and the AI tools you already use.

Everything CASRAI publishes — this page, the dictionary, the guides and the news — stays open to read, with no account and no card.

Referenced across the research world

University of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logoUniversity of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logo
  • University of Cambridge logo
  • Columbia University logo
  • Crossref logo
  • University of Edinburgh logo
  • Harvard University logo
  • University of Oxford logo
  • Princeton University logo
  • Stanford School of Medicine logo
  • University College London logo
  • ORCID logo

View CASRAI adoption →