A double-lumen endotracheal tube (also written double lumen endotracheal tube, or endotracheal tube double lumen) is a bifurcated airway tube with two separate channels, one ending in the trachea and one in a main bronchus, so that clinicians can ventilate or isolate either lung independently. It is used by anesthesia teams for one-lung ventilation, and this page explains what it is, how it is built, left versus right designs, what the size numbers mean, and its FDA classification.
Who uses it: anesthesiologists and thoracic surgical teams; it is also relevant to the clinic staff, buyers and students who need to tell it apart from other airway tubes.
What is a double-lumen endotracheal tube?
It is a bifurcated tube with a separate tracheal lumen and endobronchial lumen. Each lumen can be connected to the ventilator on its own, which lets one lung be ventilated while the other is isolated (a technique called one-lung ventilation) (Ashok and Francis, BJA Education 2018). In US regulation the device type is called a tracheal/bronchial differential ventilation tube: “a device used to isolate the left or the right lung of a patient for anesthesia or pulmonary function testing” (21 CFR 868.5740).
The ordinary “ET tube” is the endotracheal tube (ETT), a single-lumen tube that ends in the trachea. A double-lumen tube is a different product: it adds the second lumen and a bronchial segment.
How it is built
- Two lumens: one opening in the trachea, one extending into the left or right main bronchus.
- Two cuffs: a tracheal cuff and a bronchial cuff. The bronchial cuff and its pilot line are usually blue, which helps tell the two apart.
- Design history: the Carlens tube dates from the 1950s. Modified PVC tubes based on the Robertshaw design are the most widely used today, and disposable rubber double-lumen tubes based on the Robertshaw design are also available.
Source: Ashok and Francis, 2018.
Types and variants
| Type | Typical use | Key difference |
|---|---|---|
| Left-sided double-lumen tube | Most elective thoracic procedures | Bronchial segment enters the left main bronchus |
| Right-sided double-lumen tube | Cases where a left-sided tube is unsuitable, for example left pneumonectomy, left lung transplant, left tracheobronchial disruption, left thoracoscopic surgery, or a distorted left main bronchus (such as from aortic aneurysm or tumour compression) | Modified bronchial cuff with a side opening (Murphy’s eye) so the right upper lobe can still be ventilated |
Source for both rows: Ashok and Francis, 2018. The choice of side is a clinical decision made for the individual patient.
Related devices that are not the same product
- Single-lumen endotracheal tube: one channel, no lung isolation.
- Double-lumen tracheostomy tube: a different device, used through a tracheostomy rather than the mouth or nose; it is not a lung-isolation tube. For tracheostomy tube sizing see Shiley trach size chart.
- Bronchoscopes: flexible bronchoscopes are used to confirm tube position (see below); see bronchoscope types.
Sizes that matter
| Specification | Value | Source |
|---|---|---|
| Adult sizes | 35, 37, 39 and 41 Fr | Ashok and Francis, 2018 |
| Meaning of Fr | External diameter of the tracheal segment in mm multiplied by 3 | Ashok and Francis, 2018 |
| Traditional size guidance | 37 Fr for an average female and 39 Fr for an average male, one size up or down for larger or smaller patients | Ashok and Francis, 2018 |
| Most accurate sizing method described | CT measurement of the left main bronchus diameter | Ashok and Francis, 2018 |
How to choose
Selection is made by the treating anesthesia team, not by the purchaser. The source describes these criteria: the side of the tube follows the procedure and the anatomy (table above), and size follows the patient, with CT measurement of the left main bronchus described as the most accurate approach. Check the manufacturer’s instructions for use for the exact specifications of any product. Basic airway equipment is covered in rapid sequence intubation kit contents.
Regulatory status
Under 21 CFR 868.5740 the device type is Class II. The openFDA classification database lists product code CBI, “Tube, Tracheal/Bronchial, Differential Ventilation (W/Wo Connector)”, Class 2, regulation number 868.5740 (openFDA, read 2026-11-07).
Safe use and handling basics
The source notes that position is checked after insertion, and bronchoscopic (fiberoptic) confirmation is part of standard assessment: for a left-sided tube the bronchial cuff should appear as a thin blue crest in the left main bronchus without herniating over the carina, and for a right-sided tube bronchoscopy is described as essential to align the side opening with the right upper lobe. Malposition is the most commonly reported complication and can result from cuff overinflation, head and neck movement, or surgical manipulation. Airway trauma is another reported risk, from an oversized tube or from an undersized tube that migrates distally. Because of these risks, placement and confirmation are performed only by trained clinicians following the manufacturer’s instructions for use.
Common mistakes
- Treating “ET tube” and “double-lumen tube” as interchangeable; they are different products.
- Confusing a double-lumen endotracheal tube with a double-lumen tracheostomy tube, or with esophageal-tracheal double-lumen airways, which are separate device types.
- Assuming size is chosen from a table alone; the source describes imaging-based sizing as the most accurate method.
FAQ
How to place a double lumen tube?
Placement is a clinician-performed procedure, so this page does not give steps. In general terms, the source describes checking the cuffs before use and confirming position afterwards by clamping and listening to each lung and by fiberoptic bronchoscopy. Follow the manufacturer’s instructions for use and local clinical protocols.
What is an ET tube called?
ET tube is short for endotracheal tube, abbreviated ETT. A double-lumen endotracheal tube is a specialized version with two lumens.
What is the 7-8-9 rule for endotracheal tube placement?
This page does not cover that rule. It applies to standard single-lumen tubes, not to double-lumen tube sizing, which uses the Fr sizes and anatomical criteria above.
What is a double lumen tracheostomy tube?
It is a tracheostomy tube product, a different device from a double-lumen endotracheal tube, and it is not used for lung isolation. See the tracheostomy tube sizing guide linked above.
Related supplies
Related respiratory supplies are listed under CPAP and oxygen masks.
Sources
- Ashok V, Francis J. A practical approach to adult one-lung ventilation. BJA Education 2018;18(3):69-74. PMC7808029 (read 2026-11-07).
- 21 CFR 868.5740, Tracheal/bronchial differential ventilation tube. law.cornell.edu (read 2026-11-07).
- openFDA device classification, regulation number 868.5740 (queried 2026-11-07).