What Is a Miller-Abbott Tube? Double-Lumen Design and FDA Class

A Miller-Abbott tube is a double-lumen intestinal tube with a tip balloon. See its design, FEF vs FEG product codes and 21 CFR 876.5980 Class II status.

Written and maintained by CASRAI Editorial Board

Published · Last updated

This page describes products and general use; it is not medical advice.

On this page

A Miller-Abbott tube is a long, flexible, double-lumen tube with an inflatable balloon at its tip, designed for decompressing or intubating the small intestine. It is a historic device named for the two physicians behind it, and in the United States it falls under FDA regulation 21 CFR 876.5980 as a Class II gastrointestinal tube. Who uses it: hospital clinicians who manage bowel obstruction, and students and buyers who need to tell it apart from shorter stomach tubes.

What is a Miller-Abbott tube?

It is a double-lumen intestinal tube. One lumen connects to a balloon at the tip; the other lumen is open at its distal end and is used to withdraw material from the intestine or to introduce fluids (Miller, 1948). The tube is intended to travel through the small bowel rather than stop in the stomach, which is what separates it from a nasogastric tube.

How is it built?

Miller described the design in a 1948 lecture published in the Cleveland Clinic Quarterly. The tube has two lumens: one inflates the balloon, and the second is open at the distal end for drainage or fluid delivery. Miller wrote that the balloon let the clinicians reach the small bowel quickly, where earlier tubes had needed three or four days, and that it also served as a means of recording pressure changes. Rubber manufacturers had never made a double-lumen tube except for the short ones used by urologists, and it took about a year to obtain a satisfactory one made by extrusion.

Feature Miller-Abbott (double lumen) Source
Lumens Two: one for the balloon, one open at the distal end Miller 1948
Tip Inflatable balloon Miller 1948; 21 CFR 876.5980
Drainage lumen use Withdrawing intestinal contents or introducing fluids Miller 1948
FDA product code FEG FDA Product Classification database

Types and variants: FEF and FEG

The FDA regulation lists both a single-lumen and a double-lumen intestinal tube among the generic gastrointestinal tube types. The two have separate product codes.

Type FDA product code and name Regulation and class
Double-lumen intestinal tube (the Miller-Abbott design) FEG: Tube, Double Lumen For Intestinal Decompression And/Or Intubation 21 CFR 876.5980, Class 2
Single-lumen tube with mercury-weight balloon FEF: Tube, Single Lumen, With Mercury Wt Balloon For Intestinal Intubation And / Or Decompression 21 CFR 876.5980, Class 2

In both product codes, the FDA database lists the device as not an implant and not life-sustaining, and not exempt from good manufacturing practice requirements.

Where the name comes from

T. Grier Miller built the original double-lumen tube, and William Osler Abbott arranged for its manufacture, perfected the technique, described its use for diagnosing and treating obstruction, and personally carried out more than 500 intubations (Schnabel, 2001). Intestinal intubation had been developed by 1934, and Miller credited himself and Abbott with making it practical by combining a double-lumen tube with a balloon. Many people associated only Abbott’s name with the tube, and Schnabel notes that Abbott himself corrected the manufacturer’s first brochure.

FDA classification

21 CFR 876.5980 identifies a gastrointestinal tube as flexible or semi-rigid tubing used for instilling fluids into, withdrawing fluids from, splinting, or suppressing bleeding of the alimentary tract, which may incorporate an integral inflatable balloon for retention or hemostasis. The regulation names a double-lumen tube for intestinal decompression or intubation and a single-lumen tube with a mercury-weight balloon. The device type is Class II (special controls); the exemptions in the regulation apply only to specific other items such as a barium enema retention catheter and a gastrostomy tube holder.

How to choose

Choice of an intestinal tube is a clinical decision made by the treating team. One point of regulatory status: in the FDA product classification, intestinal decompression and intubation tubes sit under product codes FEG and FEF within 21 CFR 876.5980. For related tubes, see the guides on the Salem sump, the Sengstaken-Blakemore tube and gastrostomy tube types.

Safe use and handling basics

Intestinal tubes are used in a clinical setting under the direction of a physician and following the manufacturer’s instructions for use. This page does not give insertion, placement, inflation or removal steps. Because the FDA regulation includes a mercury-weight balloon variant, staff should follow the manufacturer’s instructions and their facility’s policy for handling any such product.

Common mistakes

  • Confusing it with a nasogastric tube: the nasogastric tube is a gastric tube (see parts of a nasogastric tube); the Miller-Abbott design is meant for the small intestine and has a balloon lumen.
  • Confusing it with the Sengstaken-Blakemore tube, which is a balloon tube for suppressing bleeding.
  • Treating Miller-Abbott as a single-lumen mercury tube. The double-lumen design is FEG; the single-lumen mercury-weight tube is FEF.
  • Crediting only Abbott: Miller constructed the original tube.

Frequently asked questions

What is a Miller-Abbott tube used for?

It is used for intestinal decompression and intubation, including in obstruction of the small bowel (Miller, 1948; 21 CFR 876.5980).

Who invented the Miller-Abbott tube?

Miller constructed the original double-lumen tube, and Abbott arranged its manufacture and developed its clinical use (Schnabel, 2001).

What FDA class is it?

Class II under 21 CFR 876.5980, product codes FEG (double lumen) and FEF (single lumen, mercury-weight balloon).

Is it still used?

A 2012 AJR study of 21 patients with small-bowel obstruction reported on the Miller-Abbott tube, so it still appears in the clinical literature (Park et al., 2012).

Sources

  • 21 CFR 876.5980, Gastrointestinal tube and accessories, law.cornell.edu (checked 2026-10-30).
  • FDA openFDA device classification, product codes FEF and FEG, api.fda.gov (data updated 2026-10-19; checked 2026-10-30).
  • Miller TG. Intestinal Intubation. Cleveland Clinic Quarterly 1948;16(2):68, ccjm.org (checked 2026-10-30).
  • Schnabel TG Jr. William Osler Abbott: his double lumen tube. Trans Am Clin Climatol Assoc 2001;112:50-60, PMID 11413782 (checked 2026-10-30).
  • Park JH et al. AJR Am J Roentgenol 2012;198(3):W274-8, PMID 22358025 (checked 2026-10-30).

Follow CASRAI

Research-administration guidance, standards updates and independent tool reviews.

Ask CASRAI · free to try

Ask about What Is a Miller-Abbott Tube? Double-Lumen Design and FDA Class

2 free questions a day, no account.

An AI assistant for research: funder rules, compliance, methods and publishing. It links the sources behind its answers and labels answers that come from a web search.

Answers draw on CASRAI's guides and dictionary plus the federal and funder documents we index: Federal Register, Grants.gov, Regulations.gov and UKRI.

Works on this site and inside Claude, Cursor and the AI tools you already use.

Everything CASRAI publishes — this page, the dictionary, the guides and the news — stays open to read, with no account and no card.

Referenced across the research world

University of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logoUniversity of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logo
  • University of Cambridge logo
  • Columbia University logo
  • Crossref logo
  • University of Edinburgh logo
  • Harvard University logo
  • University of Oxford logo
  • Princeton University logo
  • Stanford School of Medicine logo
  • University College London logo
  • ORCID logo

View CASRAI adoption →