Written and maintained by CASRAI Editorial Board
Published
This page describes products and general use; it is not medical advice.
On this page
A KF94 mask is a Korean-graded filtering face mask: “KF” stands for “Korea Filter”, and the number is the filtration grade shown on the mask. It is a regulated quasi-drug product in South Korea, not a brand. This page sets out what the KF grades mean according to Korea’s Ministry of Food and Drug Safety (MFDS), how the Korean test method differs from N95 and KN95 test methods, and what the US FDA’s own mask and respirator definitions say. Who uses it: people who wear filtering masks in daily life, and buyers and staff who need to read the marking on an imported mask.
Ask CASRAI · free to tryQuestion about this guide? Ask CASRAI answers with linked sources. 2 free questions a day, no account.
What a KF94 mask is
MFDS states that KF masks are quasi-drugs whose manufacture and distribution are regulated, and that KF is an acronym for Korea Filter, followed by numbers or letters referring to the performance of the mask. KF filtering respirators carry a KF grade (KF99, KF94 or KF80) indicating filtration efficiency. KF94 is therefore one grade within a regulated marking system, not the name of a manufacturer.
KF grades according to MFDS
| Marking | What MFDS says it indicates |
|---|---|
| KF80 | Average particle filtration of 80% for 0.6 μm particles |
| KF94 | Average particle filtration of 94% for 0.4 μm particles |
| KF99 | Average particle filtration of 99% for 0.4 μm particles |
| KF-AD | Anti-droplet mask, for daily wear against droplets |
MFDS ranks particle filtration as KF99 > KF94 > KF80 > anti-droplet/surgical mask, and breathability in the reverse order. The MFDS page prints the grade values with a comparison sign, so read each percentage as the grade’s filtration level and consult the page itself for the exact wording (source 1).
How KF94 testing compares with N95, KN95 and FFP2
A 2021 study in Scientific Reports (Corbin et al.) tabulated the test parameters of four standards: N95 (42 CFR 84), KN95 (GB2626-2019), FFP2 (EN 149-2001) and the Korea 1st Class standard (KMOEL-2017-64). The table below reproduces its Table 3 values. The study refers to the Korean standard as “Korea 1st Class”; MFDS markets its filtering respirator grades as KF99, KF94 and KF80, and this page does not state which MFDS grade corresponds to which row beyond what the sources say.
| Test parameter | N95 | KN95 | FFP2 | Korea 1st Class |
|---|---|---|---|---|
| Test aerosol | NaCl | NaCl | NaCl + oil | NaCl + oil |
| Flow rate (L/min) | 85 | 85 | 95 | 95 |
| Max. inhalation/exhalation resistance (Pa) | <245 | <250 | <240 | <240 |
| Particle MMAD | 300 nm | 300 nm | 600 nm | 600 nm |
| Equilibrium charge neutralisation | Yes | Yes | No | No |
| Mass loading | 200 mg | 200 ± 5 mg | 120 mg | Not specified |
The practical reading: the Korean and European methods use a larger test particle and higher flow rate than the US and Chinese methods, so the headline percentages from different standards are not measured under identical conditions. For the US respirator standard itself, see what an N95 respirator is and the NIOSH-approved respirator list guide.
What a KF mark does and does not mean in the US
The FDA’s page on N95 respirators, surgical masks, face masks and barrier face coverings defines the categories by fit and function. A face mask covers the wearer’s nose and mouth, is not personal protective equipment, and may or may not meet fluid barrier or filtration efficiency levels. A surgical mask is a loose-fitting, disposable device whose edges are not designed to form a seal. An N95 respirator is designed to achieve a very close facial fit, with edges designed to form a seal. FDA also states that barrier face coverings and face masks are not a substitute for N95 respirators. That page does not mention KF94, so the KF marking itself carries no US regulatory status in the sources read here.
Safe use and handling basics
- Check the marking on the product against the grade you intend (KF94, KF80, KF99 or KF-AD) as described by MFDS, since MFDS advises checking the KF mark when buying masks.
- Fit matters for any respirator-type product: FDA describes seal and close facial fit as the distinguishing feature of respirators. Where a workplace requires respirators, formal fit testing applies; see the OSHA respirator fit test guide.
- Follow the manufacturer’s instructions for use on the pack for wear time and disposal.
Common mistakes
- Treating KF94 as a brand name rather than a grade.
- Assuming KF94, KN95 and N95 percentages are directly interchangeable, when the test aerosol, flow rate and particle size differ (table above).
- Assuming an anti-droplet (KF-AD) mask offers the filtration of a KF94 mask; MFDS ranks it lower on particle filtration.
For a size-related comparison of respirators, see N95 sizes.
FAQ
What is a KF94 face mask?
A filtering face mask carrying the Korean KF94 grade. MFDS describes KF masks as regulated quasi-drugs and lists KF94 at 94% average filtration of 0.4 μm particles.
What is the No. 1 face mask in Korea?
No source read for this page ranks mask brands, so no ranking is given. KF94 is a filtration grade that many products carry, not a single brand.
What is a KN95 mask used for?
KN95 is the Chinese respirator class under GB2626-2019. In the comparison above it is tested with NaCl aerosol at 85 L/min with a 300 nm particle, the same parameters as N95 in that study.
What kind of mask protects against COVID?
This page gives product information, not medical advice. FDA’s definitions show the structural difference: respirators are designed to seal to the face, while surgical and other face masks are not, and FDA states face masks and barrier face coverings are not a substitute for N95 respirators. For personal decisions, consult a health professional or current public health guidance.
Sources
- Korea Ministry of Food and Drug Safety (MFDS), “Make sure to check KF mark when buying masks”, mfds.go.kr, read 2026-11-07.
- US FDA, “N95 Respirators, Surgical Masks, Face Masks, and Barrier Face Coverings”, fda.gov, read 2026-11-07.
- Corbin J-S et al., Scientific Reports 2021 (corrected 2022), Table 3, PMC8578374, read 2026-11-07.







