Skip to main content
v2026.11,986 entries · CC-BY 4.0

What Is an FFP2 Mask? EN 149 Class, Tests and Use

What an FFP2 mask is: its EN 149 class, HSE protection factor of 10, how its test conditions differ from N95, and use limits.

Written and maintained by CASRAI Editorial Board

Published

This page describes products and general use; it is not medical advice.

On this page

An FFP2 mask is a disposable filtering facepiece respirator in the middle class of the European standard EN 149 (classes FFP1, FFP2 and FFP3). The UK Health and Safety Executive (HSE) gives FFP2 an assigned protection factor of 10, between FFP1 at 4 and FFP3 at 20. It is a close-fitting respirator, not a loose surgical mask. This page covers what the class means, how its test conditions differ from the US N95, and the use conditions HSE attaches to it.

Who uses it: workers and employers who select respiratory protective equipment (RPE) against solid or liquid particles, and the clinic staff, buyers and students who need to read an FFP2 label correctly.

Ask CASRAI · free to tryQuestion about this guide? Ask CASRAI answers with linked sources. 2 free questions a day, no account.

Ask your first question freeSubscribe

What an FFP2 mask is

HSE’s guide Respiratory protective equipment at work (HSG53, 4th edition, 2013) lists FFP1, FFP2 and FFP3 as disposable half mask respirators, tested to BS EN 149, effective against solid or liquid particles. The guide notes that these are sometimes called filtering facepiece or orinasal respirators. The mask itself is the filter: there is no separate cartridge. For the US counterpart see what an N95 respirator is; for the Korean grade see what a KF94 mask is.

The FDA distinguishes respirators from surgical masks: respirators are designed for a close facial fit and seal, while surgical masks are loose-fitting (FDA, N95 Respirators, Surgical Masks, Face Masks, and Barrier Face Coverings).

How it is built and tested

EN 149 certifies the whole mask against a filtration test, a breathing resistance test and other requirements. The EN 149 text itself is sold by standards bodies, so this page relies on the published comparison by Corbin and colleagues (Scientific Reports, 2021, Table 3), which sets the FFP2 test conditions beside those of other national standards:

Test parameter FFP2 (EN 149:2001) N95 (42 CFR Part 84)
Test particles NaCl and oil (paraffin oil) NaCl
Particle size, count median diameter 20 nm to 2 μm 75 nm
Particle size, mass median aerodynamic diameter 600 nm 300 nm
Flow rate 95 L/min 85 L/min
Flow resistance limit below 240 Pa below 245 Pa
Equilibrium charge neutralisation not required required
Mass loading 120 mg 200 mg
Preconditioning hot and cold, plus unconditioned samples humid

The same paper notes that the FFP2 standard measures breathing resistance at a higher flow than its filtration test, and that a respirator whose performance improves after conditioning might be certified N95 but not FFP2. This is why “FFP2 equals N95” is only an approximation: the two are tested differently, so a published efficiency figure for one is not a substitute for the other’s certification. Efficiency percentages are set in the EN 149 text and are not reproduced here.

FFP classes compared

Class Assigned protection factor (HSE) Conditions HSE states for disposable half masks
FFP1 4 Medium work rate; continuous wear under 1 hour; fit test required
FFP2 10 Medium work rate; continuous wear under 1 hour; fit test required
FFP3 20 Medium work rate; continuous wear under 1 hour; fit test required

Source: HSE HSG53, Figure 8, disposable half mask respirators; applicable standard BS EN 149. The same figure lists a reusable half mask with P1, P2 or P3 filters at the same factors of 4, 10 and 20 (BS EN 140 mask with BS EN 143 filter); see half-face respirators.

How the class is regulated in the EU

Regulation (EU) 2016/425 sets the rules for personal protective equipment (PPE). Article 18 classifies PPE by risk category under Annex I, and Category III includes risks from substances and mixtures hazardous to health. Under Article 19, Category III products need EU type-examination (module B, Annex V) plus one of the listed conformity modules. Respiratory requirements appear in Annex II, point 3.10.1. Annex I does not name respiratory protective devices individually, so check the manufacturer’s declaration of conformity for the category of a specific product rather than assuming it.

How to choose: what the HSE guide states

  • Match the assigned protection factor to the hazard assessment: FFP1 gives 4, FFP2 gives 10 and FFP3 gives 20.
  • HSE says P1 and P2 filters are not recommended for fumes unless stated otherwise.
  • Fit testing, qualitative or quantitative, is required for disposable half masks (fit varies with face shape; for US sizing see N95 sizes). See the respirator fit test guide.

Safe use and handling basics

  • HSE says to dispose of masks marked NR (not reusable) after a single shift (8 hours).
  • HSE lists continuous wear time for disposable half masks as less than 1 hour.
  • A respirator is designed to seal to the face, so a fit test on the wearer’s face is the basis for a good seal (HSE; FDA).

Common mistakes

  • Treating FFP2 as identical to N95 or KF94. The test conditions above differ.
  • Using a P1 or P2 rated product against fumes when the manufacturer has not stated it is suitable.
  • Reusing a mask marked NR beyond a single shift.
  • Skipping the fit test for a disposable half mask.
  • Using a loose-fitting surgical mask where a respirator is specified.

FAQ

Is an FFP2 mask the same as an N95?

No. They are regarded as similar classes, but they are certified to different standards (EN 149 versus 42 CFR Part 84) with different flow rates, particle sizes, mass loading and preconditioning, as the table above shows.

What protection factor does an FFP2 mask have?

HSE assigns FFP2 a protection factor of 10, compared with 4 for FFP1 and 20 for FFP3.

Does an FFP2 mask need a fit test?

HSE’s guide states that fit testing is required for disposable half mask respirators, qualitative or quantitative.

Is an FFP2 mask the same as a surgical mask?

No. The FDA describes respirators as designed for close facial fit and seal, and surgical masks as loose-fitting.

Sources

Follow CASRAI

Research-administration guidance, standards updates and independent tool reviews.

Ask CASRAI · free to try

Ask about What Is an FFP2 Mask? EN 149 Class, Tests and Use

2 free questions a day, no account.

An AI assistant for research: funder rules, compliance, methods and publishing. It links the sources behind its answers and labels answers that come from a web search.

Answers draw on CASRAI's guides and dictionary plus the federal and funder documents we index: Federal Register, Grants.gov, Regulations.gov and UKRI.

Works on this site and inside Claude, Cursor and the AI tools you already use.

Everything CASRAI publishes — this page, the dictionary, the guides and the news — stays open to read, with no account and no card.

Referenced across the research world

University of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logoUniversity of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logo
  • University of Cambridge logo
  • Columbia University logo
  • Crossref logo
  • University of Edinburgh logo
  • Harvard University logo
  • University of Oxford logo
  • Princeton University logo
  • Stanford School of Medicine logo
  • University College London logo
  • ORCID logo

View CASRAI adoption →