Written and maintained by CASRAI Editorial Board
Published
This page describes products and general use; it is not medical advice.
On this page
An FFP2 mask is a disposable filtering facepiece respirator in the middle class of the European standard EN 149 (classes FFP1, FFP2 and FFP3). The UK Health and Safety Executive (HSE) gives FFP2 an assigned protection factor of 10, between FFP1 at 4 and FFP3 at 20. It is a close-fitting respirator, not a loose surgical mask. This page covers what the class means, how its test conditions differ from the US N95, and the use conditions HSE attaches to it.
Who uses it: workers and employers who select respiratory protective equipment (RPE) against solid or liquid particles, and the clinic staff, buyers and students who need to read an FFP2 label correctly.
Ask CASRAI · free to tryQuestion about this guide? Ask CASRAI answers with linked sources. 2 free questions a day, no account.
What an FFP2 mask is
HSE’s guide Respiratory protective equipment at work (HSG53, 4th edition, 2013) lists FFP1, FFP2 and FFP3 as disposable half mask respirators, tested to BS EN 149, effective against solid or liquid particles. The guide notes that these are sometimes called filtering facepiece or orinasal respirators. The mask itself is the filter: there is no separate cartridge. For the US counterpart see what an N95 respirator is; for the Korean grade see what a KF94 mask is.
The FDA distinguishes respirators from surgical masks: respirators are designed for a close facial fit and seal, while surgical masks are loose-fitting (FDA, N95 Respirators, Surgical Masks, Face Masks, and Barrier Face Coverings).
How it is built and tested
EN 149 certifies the whole mask against a filtration test, a breathing resistance test and other requirements. The EN 149 text itself is sold by standards bodies, so this page relies on the published comparison by Corbin and colleagues (Scientific Reports, 2021, Table 3), which sets the FFP2 test conditions beside those of other national standards:
| Test parameter | FFP2 (EN 149:2001) | N95 (42 CFR Part 84) |
|---|---|---|
| Test particles | NaCl and oil (paraffin oil) | NaCl |
| Particle size, count median diameter | 20 nm to 2 μm | 75 nm |
| Particle size, mass median aerodynamic diameter | 600 nm | 300 nm |
| Flow rate | 95 L/min | 85 L/min |
| Flow resistance limit | below 240 Pa | below 245 Pa |
| Equilibrium charge neutralisation | not required | required |
| Mass loading | 120 mg | 200 mg |
| Preconditioning | hot and cold, plus unconditioned samples | humid |
The same paper notes that the FFP2 standard measures breathing resistance at a higher flow than its filtration test, and that a respirator whose performance improves after conditioning might be certified N95 but not FFP2. This is why “FFP2 equals N95” is only an approximation: the two are tested differently, so a published efficiency figure for one is not a substitute for the other’s certification. Efficiency percentages are set in the EN 149 text and are not reproduced here.
FFP classes compared
| Class | Assigned protection factor (HSE) | Conditions HSE states for disposable half masks |
|---|---|---|
| FFP1 | 4 | Medium work rate; continuous wear under 1 hour; fit test required |
| FFP2 | 10 | Medium work rate; continuous wear under 1 hour; fit test required |
| FFP3 | 20 | Medium work rate; continuous wear under 1 hour; fit test required |
Source: HSE HSG53, Figure 8, disposable half mask respirators; applicable standard BS EN 149. The same figure lists a reusable half mask with P1, P2 or P3 filters at the same factors of 4, 10 and 20 (BS EN 140 mask with BS EN 143 filter); see half-face respirators.
How the class is regulated in the EU
Regulation (EU) 2016/425 sets the rules for personal protective equipment (PPE). Article 18 classifies PPE by risk category under Annex I, and Category III includes risks from substances and mixtures hazardous to health. Under Article 19, Category III products need EU type-examination (module B, Annex V) plus one of the listed conformity modules. Respiratory requirements appear in Annex II, point 3.10.1. Annex I does not name respiratory protective devices individually, so check the manufacturer’s declaration of conformity for the category of a specific product rather than assuming it.
How to choose: what the HSE guide states
- Match the assigned protection factor to the hazard assessment: FFP1 gives 4, FFP2 gives 10 and FFP3 gives 20.
- HSE says P1 and P2 filters are not recommended for fumes unless stated otherwise.
- Fit testing, qualitative or quantitative, is required for disposable half masks (fit varies with face shape; for US sizing see N95 sizes). See the respirator fit test guide.
Safe use and handling basics
- HSE says to dispose of masks marked NR (not reusable) after a single shift (8 hours).
- HSE lists continuous wear time for disposable half masks as less than 1 hour.
- A respirator is designed to seal to the face, so a fit test on the wearer’s face is the basis for a good seal (HSE; FDA).
Common mistakes
- Treating FFP2 as identical to N95 or KF94. The test conditions above differ.
- Using a P1 or P2 rated product against fumes when the manufacturer has not stated it is suitable.
- Reusing a mask marked NR beyond a single shift.
- Skipping the fit test for a disposable half mask.
- Using a loose-fitting surgical mask where a respirator is specified.
FAQ
Is an FFP2 mask the same as an N95?
No. They are regarded as similar classes, but they are certified to different standards (EN 149 versus 42 CFR Part 84) with different flow rates, particle sizes, mass loading and preconditioning, as the table above shows.
What protection factor does an FFP2 mask have?
HSE assigns FFP2 a protection factor of 10, compared with 4 for FFP1 and 20 for FFP3.
Does an FFP2 mask need a fit test?
HSE’s guide states that fit testing is required for disposable half mask respirators, qualitative or quantitative.
Is an FFP2 mask the same as a surgical mask?
No. The FDA describes respirators as designed for close facial fit and seal, and surgical masks as loose-fitting.
Sources
- Health and Safety Executive, Respiratory protective equipment at work: a practical guide (HSG53, 4th ed., 2013), hse.gov.uk/pubns/priced/hsg53.pdf, Figure 8. Read 2026-11-08.
- Corbin J-S et al., Scientific Reports (2021, corrected 2022), Table 3, PMC8578374. Read 2026-11-08.
- Regulation (EU) 2016/425 on personal protective equipment, EUR-Lex. Read 2026-11-08.
- US FDA, N95 Respirators, Surgical Masks, Face Masks, and Barrier Face Coverings. Read 2026-11-08.