What Is a Perfusion Pump? Types, Uses and FDA Classes

A perfusion pump moves fluid through a circuit: a bypass blood pump in surgery or a culture pump in the lab. See types, uses and FDA classes.

Written and maintained by CASRAI Editorial Board

Published

On this page

A perfusion pump is a pump that drives a fluid through a circuit or a chamber at a controlled rate. The term covers two quite different devices: a cardiopulmonary bypass blood pump, which the US FDA regulates as a prescription medical device used during heart surgery, and a laboratory continuous perfusion pump, which keeps culture medium flowing through cells or an organ-on-chip system and is sold for research use only. Which one a document means depends on the setting, and the regulatory status differs completely between them.

This page describes products and general use; it is not medical advice.

What a perfusion pump is

Perfusion means moving fluid through a vessel, a tissue or a culture. A perfusion pump is the pump element that does the moving. In the operating room it pushes blood through an extracorporeal circuit; on the bench it pushes medium past cultured cells. The word is also easy to confuse with an infusion pump, which delivers a measured volume of fluid to a patient and is a separate device covered in our guide to the IV infusion pump.

Under US federal regulation, a roller-type cardiopulmonary bypass blood pump is defined as a device that uses a revolving roller mechanism to pump the blood through the cardiopulmonary bypass circuit during bypass surgery (21 CFR 870.4370). A nonroller-type pump is defined as a prescription device that uses a method other than revolving rollers to pump the blood through an extracorporeal circuit (21 CFR 870.4360). The laboratory version has no such regulatory definition: one vendor describes its dual-channel continuous perfusion pump as a vertical-configuration instrument for cell culture and organ-on-chip work.

Who uses it. Cardiopulmonary bypass pumps are used by the cardiac surgery team in the operating room. Laboratory perfusion pumps are used by researchers running cell-culture, organ-on-chip and other flow-based experiments.

Two meanings of the term

Meaning Setting Regulatory position
Cardiopulmonary bypass blood pump Cardiac surgery, extracorporeal circuit Regulated by FDA under 21 CFR 870.4360 and 870.4370; Class II for bypass pumps
Laboratory continuous perfusion pump Cell culture, organ-on-chip, pre-clinical research Labelled by the vendor example reviewed as pre-clinical research and veterinary use only, not clinical use

Related background pages: the oxygenator is the gas-exchange component that sits in a bypass circuit alongside the blood pump, and a microfluidic chip is a typical destination for laboratory perfusion flow.

How a bypass blood pump is built and how it works

The FDA regulations split bypass blood pumps by how they move blood. A roller-type pump uses a revolving roller mechanism. A nonroller-type pump uses a method other than revolving rollers; centrifugal pumps, such as the Terumo example below, are of this kind. A third regulated item, the cardiopulmonary bypass pump speed control, is a device that incorporates an electrical system, a mechanical system, or both, and is used to control the speed of blood pumps used in cardiopulmonary bypass surgery (21 CFR 870.4380). The pump and its speed control are therefore defined as separate devices even though they work as a pair.

A centrifugal pump as a worked product example

Terumo describes its Capiox iCP centrifugal pump as having a 55 mL prime volume, an efficient impeller design, a polycarbonate housing, low heat generation and low hemolysis, and a biocompatible amphiphilic polymer surface coating called Xcoating. The manufacturer states the pump is compatible with the Terumo Advanced Perfusion System 1 and also works with LivaNova S5 and S3 heart-lung machines with no adapter needed. These are manufacturer statements about one product; they are not a comparison with other pumps, and the page does not publish a flow range.

How a laboratory perfusion pump is built and how it works

The laboratory example reviewed is a dual-channel pump. It has two independent flow paths, each with its own pump head, so the channels can run at different flow rates or protocols. The vendor states that it uses a precision motor-driven mechanism with variable-speed control, works with standard laboratory tubing, offers bidirectional continuous flow, and includes precision flow sensors that give real-time feedback for flow control. The vendor adds that flow rate specifications depend on tubing diameter and viscosity, which is the general reason a stated pump speed does not translate directly into a delivered flow: the tubing and the fluid both set the result. Tubing diameters and wall thicknesses are listed in the product datasheet rather than on the product page.

Types and variants

Type Typical use Key difference
Roller-type cardiopulmonary bypass blood pump Pumping blood through the bypass circuit during bypass surgery Uses a revolving roller mechanism (21 CFR 870.4370)
Nonroller-type cardiopulmonary and circulatory bypass blood pump Full or partial heart-lung bypass during open heart or great vessel surgery, or temporary flow diversion in aorta or vena cava surgery, for under 6 hours Uses a method other than revolving rollers; prescription device (21 CFR 870.4360(a))
Nonroller-type temporary ventricular support blood pump Temporary ventricular assistance when heart function is temporarily unstable from reversible causes, for under 6 hours Any method of blood propulsion; higher regulatory class (21 CFR 870.4360(b))
Cardiopulmonary bypass pump speed control Controlling the speed of blood pumps in bypass surgery Electrical, mechanical or combined control system rather than a pump (21 CFR 870.4380)
Laboratory continuous perfusion pump (one vendor example) Cell culture and organ-on-chip work Research use only; not for clinical use

Roller and centrifugal pumps compared in clinical studies

Because the two main bypass pump types are both in routine use, they have been compared in clinical research. A 2018 randomized trial in the Brazilian Journal of Cardiovascular Surgery enrolled 60 patients having coronary artery bypass grafting, 30 on a roller pump and 30 on a centrifugal pump, and measured markers of hemolysis and inflammation. It found no significant between-group difference in those variables; the number of significant associations between hemolysis and inflammation markers was higher in the roller pump group. A 2023 systematic review in the Journal of Cardiothoracic Surgery pooled 64 randomized trials covering 3,434 patients and reported significantly lower plasma-free hemoglobin and haptoglobin outcomes for centrifugal pumps than for roller pumps, while noting that hemolysis has several contributing factors beyond pump type. The studies measure laboratory markers; they do not give a basis for choosing a pump for an individual patient.

Regulatory classes that matter

The FDA classification of each bypass pump type, from the Code of Federal Regulations, is in the data table below the article. In short: roller-type bypass pumps are Class II with performance standards; nonroller-type bypass and circulatory bypass pumps are Class II with special controls; the nonroller-type temporary ventricular support pump is Class III and requires premarket approval; and the pump speed control is Class II with performance standards.

For the nonroller-type bypass pump, the special controls cover performance testing, biocompatibility of patient-contacting parts, sterility and shelf-life testing, and labeling that states the duration of use and summarizes device- and procedure-related complications. These regulations apply to devices intended for human use. A research-only laboratory perfusion pump is offered by its vendor for pre-clinical research and veterinary use, not for clinical use, so the bypass classifications above do not describe it.

Specifications that matter

Specification Value stated by the source Source context
Prime volume of one centrifugal bypass pump 55 mL Terumo Capiox iCP product page
Maximum duration for nonroller bypass pump classification Under 6 hours 21 CFR 870.4360
Independent channels on the lab pump example 2 Vendor product page
Factors the vendor says set lab flow rate Tubing diameter and viscosity Vendor product page; no numeric range published there

How to read a product description

The sources support a few checks that reduce the chance of mixing up the two device families. First, confirm the intended-use statement: a bypass pump is a prescription device with a regulatory classification, while a laboratory perfusion pump states research-only use. Second, for a bypass pump, check which regulation covers it, since roller-type and nonroller-type pumps appear in different parts of 21 CFR 870.4360 and 870.4370. Third, check compatibility with the surrounding equipment: Terumo states which heart-lung machines its pump works with, and a laboratory pump’s datasheet lists the tubing it is specified for. Fourth, check duration limits: the nonroller bypass and ventricular support pump definitions in the regulation are tied to use under six hours.

Safe use and handling basics

Bypass pumps are prescription devices used by trained surgical and perfusion staff under the manufacturer’s instructions for use; this page gives no operating instructions. For laboratory pumps, the vendor’s page says that the product is for pre-clinical research and veterinary use only, not for human consumption or clinical use, so it should not be moved into clinical workflows. Flow depends on tubing diameter and viscosity, so use the tubing the datasheet lists and recheck the delivered flow when the medium changes. For biological work, the lab’s own biosafety and equipment procedures apply; see the microdialysis guide for another continuous-perfusion research technique.

Common mistakes

  • Treating a perfusion pump as an infusion pump. They are different device families with different purposes.
  • Assuming a research pump can be used clinically. The vendor example is stated as not for clinical use.
  • Quoting a pump speed as a flow rate. The laboratory vendor states flow depends on tubing diameter and viscosity.
  • Reading the clinical comparisons as a ranking. The cited studies compare laboratory markers in groups of patients and say nothing about which pump suits a given patient.
  • Overlooking the pump speed control. FDA regulates the speed control as its own device.

Sources

Data: FDA classification of cardiopulmonary bypass blood pump devices (21 CFR 870.4360, 870.4370, 870.4380)

Compares the four regulated bypass pump device types by identification, FDA class and regulatory basis, compiled from the text of the Code of Federal Regulations as published by the Legal Information Institute.

Period covered: 2026. Coverage: United States.

FDA classification of cardiopulmonary bypass blood pump devices (21 CFR 870.4360, 870.4370, 870.4380)
DeviceCFR sectionFDA classRegulatory basisStated use limit
Roller-type cardiopulmonary bypass blood pump21 CFR 870.4370IIPerformance standardsBypass surgery circuit; no duration stated
Nonroller-type cardiopulmonary and circulatory bypass blood pump21 CFR 870.4360(a)IISpecial controlsUnder 6 hours
Nonroller-type temporary ventricular support blood pump21 CFR 870.4360(b)IIIPremarket approvalUnder 6 hours
Cardiopulmonary bypass pump speed control21 CFR 870.4380IIPerformance standardsControls speed of bypass blood pumps; no duration stated

Sources

Compiled by CASRAI from the sources above. Free to reuse under CC BY 4.0 with attribution.

Follow CASRAI

Research-administration guidance, standards updates and independent tool reviews.

Ask CASRAI · full access

Ask about What Is a Perfusion Pump? Types, Uses and FDA Classes

Full access: large monthly usage, up to 10 source passages behind each answer, and MCP and API access for Claude Code, Codex and other CLIs. Cancel any time.

An AI assistant for research: funder rules, compliance, methods and publishing. It links the sources behind its answers and labels answers that come from a web search.

Answers draw on CASRAI's guides and dictionary plus the federal and funder documents we index: Federal Register, Grants.gov, Regulations.gov and UKRI.

Works on this site and inside Claude, Cursor and the AI tools you already use.

Everything CASRAI publishes — this page, the dictionary, the guides and the news — stays open to read, with no account and no card.

Referenced across the research world

University of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logoUniversity of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logo
  • University of Cambridge logo
  • Columbia University logo
  • Crossref logo
  • University of Edinburgh logo
  • Harvard University logo
  • University of Oxford logo
  • Princeton University logo
  • Stanford School of Medicine logo
  • University College London logo
  • ORCID logo

View CASRAI adoption →