Schlenk Tube: Anatomy, Types, Sizes and Safe Use

A Schlenk tube is specialized glassware for air-sensitive chemistry, featuring a sidearm valve for vacuum and inert gas cycling in synthetic research.

Written and maintained by CASRAI Editorial Board

Published

On this page

Who uses it: Synthetic chemists, materials scientists, and technicians handling air- and moisture-sensitive reagents, organometallic catalysts, and pyrophoric compounds use Schlenk tubes.

In chemical synthesis, isolating reactions from atmospheric oxygen and moisture is essential for reaction success. The schlenk tube is specialized glassware designed for inert-atmosphere and vacuum manipulations. Featuring an integrated sidearm stopcock or valve, a Schlenk tube allows chemists to evacuate air and backfill the vessel with dry nitrogen or argon through a Schlenk line.

What it is

A Schlenk tube is an elongated cylindrical vessel made from heavy-walled borosilicate glass with an integrated sidearm valve. It provides a sealable chamber for reactions, recrystallizations, and reagent storage under inert gas or high vacuum (< 10-3 Torr / 0.13 Pa).

Developed by German chemist Wilhelm Schlenk (1879–1943) for organolithium chemistry, the glassware prevents sensitive compounds from oxidizing or hydrolyzing. While Schlenk tubes and Schlenk flasks serve related roles, their geometries differ:

  • Schlenk Tube: Features a narrow cylindrical body. This aspect ratio minimizes liquid surface area during storage, provides a direct path for magnetic stir bars and cannula needles, and fits into narrow cooling Dewars or heating media such as a laboratory sand bath.
  • Schlenk Flask: Features a spherical round-bottom body matching electric heating mantles for boiling and reflux, similar to a standard round-bottom flask with an auxiliary gas sidearm.

How it works or is built

A Schlenk tube connects a reaction chamber to a manifold via four components:

  1. Borosilicate Body: ASTM E438 Type I, Class A borosilicate 3.3 glass (~3.3 × 10-6 K-1 expansion). Heavy walls withstand vacuum pressure differential (14.7 psi / 1.013 bar).
  2. Standard Taper Joint: Outer ground joint (14/20 or 24/40) accepting stoppers, septa, condensers, or funnels.
  3. Sidearm Conduit: Glass tube below the joint connecting via vacuum tubing to the Schlenk line.
  4. Stopcock Assembly: Controls evacuation and inert gas backfilling.

Three valve mechanisms predominate:

  • Ground-Glass Stopcock: Greased 2 mm tapered glass plug with retaining clip; durable but risks grease leaching.
  • PTFE Plug Valve (e.g., Chemglass Chem-Cap®): Greaseless 0–4 mm threaded PTFE stem seating in glass; prevents chemical contamination.
  • High-Vacuum Valve (e.g., J. Young / HI-VAC): Greaseless PTFE spindle with dual Viton or Kalrez O-rings sealing to 10-6 mbar.

Types and variants

The table below summarizes commercial Schlenk tube variants used in synthetic research.

Glassware Type Valve Mechanism Typical Application Key Difference
Ground-Glass Stopcock Tube
(e.g., Chemglass AF-0537)
2 mm ground-glass stopcock Teaching labs and routine synthesis. Requires vacuum grease; excellent heat resistance.
PTFE Chem-Cap Plug Tube
(e.g., Chemglass AF-0538)
0–4 mm threaded PTFE plug General organometallic synthesis. 100% grease-free; avoids NMR grease peaks.
High-Vacuum Valve Tube
(e.g., Kimble 218720, J. Young)
Dual Viton/Kalrez O-rings Reagent storage and NMR staging. Maintains vacuum to 10-6 mbar without grease.
Schlenk Reaction Flask
(e.g., Kimble 213100)
Sidearm with glass or PTFE valve Refluxing volumes >50 mL. Round-bottom body fits electric heating mantles.
Straus Storage Flask
(e.g., Kimble 213210)
High-vacuum valve and vapor well Solvent storage and degas transfers. Built for freeze-pump-thaw and grease-free transfers.

Sizes or specifications that matter

Verified manufacturer specifications (Chemglass and DWK Kimble Kontes) include:

Model Series Capacity Joint Size Valve Type & Bore Outer Diameter Working Volume
Chemglass AF-0537-01 / AF-0538-01 25 mL 14/20 outer 2 mm glass or 0–4 mm PTFE 28 mm 3 to 15 mL
Chemglass AF-0537-02 / AF-0538-02 50 mL 14/20 or 24/40 2 mm glass or 0–4 mm PTFE 32 mm 5 to 30 mL
Chemglass AF-0537-03 / AF-0538-03 100 mL 24/40 outer 2 mm glass or 0–4 mm PTFE 38 mm 15 to 65 mL
Chemglass AF-0537-04 / AF-0538-04 250 mL 24/40 outer 2 mm glass or 0–4 mm PTFE 50 mm 35 to 160 mL
Kimble Kontes 218720-0025 25 mL 14/20 outer 0–4 mm HI-VAC valve 28 mm 3 to 15 mL
Kimble Kontes 218720-0350 350 mL 24/40 outer 0–8 mm HI-VAC valve 60 mm 50 to 220 mL

Operating volume guidelines:

  • Stirring Headspace: Keep working volume below 60% capacity to prevent solvent bumping into the sidearm under vacuum.
  • Freeze-Pump-Thaw Degassing: Limit volume to 30% capacity; expanding frozen solvent will crack cylindrical glassware walls.

How to choose

Four criteria govern Schlenk tube selection:

  1. Spectroscopic Purity: In inorganic and organometallic chemistry, silicone grease dissolves into solvents, producing an NMR singlet at δ 0.07 ppm and inhibiting catalysts. Choose greaseless PTFE or J. Young valves.
  2. Vacuum Level & Duration: For short synthetic steps (1–4 hours), greased glass or PTFE plugs suffice. For long-term storage or high vacuum (<0.1 Torr), select J. Young dual-O-ring valves.
  3. Solvent Compatibility: Viton O-rings swell in acetone, ethyl acetate, or dichloromethane. Use Kalrez O-rings or solid PTFE plugs for demanding organic synthesis reagents.
  4. Heating and Cooling: Cylindrical tubes fit into cooling Dewars and sand baths. For vigorous boiling, choose a round-bottom Schlenk flask.

Safe use and handling basics

Operating vacuum glassware involves implosion risks and chemical reactivity. Follow these controls based on Sigma-Aldrich Technical Bulletins AL-134/AL-164, OSHA, and ACS standards:

Inspection and Drying

Inspect tubes before applying vacuum; discard vessels with star cracks or scratches, which trigger implosions. Bake glassware in an oven at 120 °C to 140 °C for 4 hours, or flame-dry on the line under vacuum, cooling under dry nitrogen or argon.

The Evacuate-Refill Cycle

Execute the standardized 3-cycle purge protocol: connect sidearm to manifold, seal top joint, evacuate for 5 to 10 minutes (<0.1 Torr), and backfill slowly with dry inert gas until the bubbler registers positive pressure. Repeat for a total of three complete cycles to eliminate oxygen and moisture.

Reagent Transfer and Shielding

Maintain positive inert gas flow during transfers. For pyrophoric substances, see protocols for reactive chemicals and pyrophoric handling. Use 18-gauge or smaller needles to avoid coring septa, and cannulae for transfers >20 mL. Always work inside a fume hood with the sash lowered, and wrap large tubes with electrical tape to contain fragments during an implosion.

Common mistakes

  • Abrupt Vacuum Opening: Sudden vacuum causes solvent bumping into the sidearm. Open valves gradually.
  • Overgreasing Joints: Excess grease dissolves into reactions, ruining spectra. Apply only a thin stripe.
  • Freezing Without Angling: Freezing vertical tubes in liquid nitrogen shatters the base. Tilt at 45 degrees while rotating.
  • Overtightening Valves: Excessive torque flattens O-rings and cracks glass barrels. Hand-tighten until firm.
  • Pressurizing Glassware: Schlenk tubes withstand vacuum but have low internal pressure tolerance. Always vent via an oil bubbler.

FAQ

What is the difference between a Schlenk tube and a Schlenk flask?

A Schlenk tube features a cylindrical body suited for small volumes, cooling Dewars, and freeze-pump-thaw degassing. A Schlenk flask features a spherical round-bottom body designed to fit heating mantles for boiling and larger reaction scales.

What is a J. Young valve on a Schlenk tube?

A J. Young valve is a greaseless tap using a threaded PTFE piston with dual fluoroelastomer O-rings (Viton or Kalrez) sealing in a precision glass barrel to 10-6 mbar without grease, preventing NMR and catalyst contamination.

Why is a Schlenk tube used instead of a standard round-bottom flask?

A standard flask lacks an atmosphere-control valve. A Schlenk tube incorporates a sidearm stopcock directly on the vessel, enabling vacuum purging, inert-gas blanketing, and cannula transfers without air exposure.

How many times should a Schlenk tube be evacuated and refilled?

Standard protocol (Sigma-Aldrich Technical Bulletin AL-134) requires a minimum of three complete evacuate-refill cycles, pulling vacuum for 5 to 10 minutes per cycle before backfilling with dry inert gas.

Can a Schlenk tube withstand positive internal pressure?

No. Standard borosilicate Schlenk tubes have low tensile tolerance for internal positive pressure. They must always be vented through an oil bubbler, or substituted with heavy-walled pressure vessels like Fisher-Porter tubes.

Sources

  • Chemglass Life Sciences. (2024). Airfree® Schlenk Glassware Catalog: Series AF-0537 & AF-0538. URL: https://chemglass.com/ (accessed 2026-11-10).
  • DWK Life Sciences. (2023). KIMBLE® Kontes® Airless-Ware® Laboratory Glassware Catalog. URL: https://dwk.com/ (accessed 2026-11-10).
  • Sigma-Aldrich. (2020). Handling Air-Sensitive Reagents. Technical Bulletin AL-134. URL: https://www.sigmaaldrich.com/ (accessed 2026-11-10).
  • GPE Scientific. (2023). J. Young Greaseless High Vacuum Stopcocks Technical Manual. URL: https://www.gpescientific.co.uk/ (accessed 2026-11-10).
  • Webster, R. (2022). The Schlenk Line Survival Guide. University of Bath. URL: https://schlenklinesurvivalguide.com/ (accessed 2026-11-10).
  • ACS Division of Chemical Health and Safety. (2021). Safety in Academic Chemistry Laboratories. Washington, DC: ACS.

Follow CASRAI

Research-administration guidance, standards updates and independent tool reviews.

Ask CASRAI · free to try

Ask about Schlenk Tube: Anatomy, Types, Sizes and Safe Use

2 free questions a day, no account.

An AI assistant for research: funder rules, compliance, methods and publishing. It links the sources behind its answers and labels answers that come from a web search.

Answers draw on CASRAI's guides and dictionary plus the federal and funder documents we index: Federal Register, Grants.gov, Regulations.gov and UKRI.

Works on this site and inside Claude, Cursor and the AI tools you already use.

Everything CASRAI publishes — this page, the dictionary, the guides and the news — stays open to read, with no account and no card.

Referenced across the research world

University of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logoUniversity of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logo
  • University of Cambridge logo
  • Columbia University logo
  • Crossref logo
  • University of Edinburgh logo
  • Harvard University logo
  • University of Oxford logo
  • Princeton University logo
  • Stanford School of Medicine logo
  • University College London logo
  • ORCID logo

View CASRAI adoption →