Written and maintained by CASRAI Editorial Board
Published · Last updated
On this page
A shaker flask (also called a shake flask) is a laboratory culture vessel, usually glass or plastic and Erlenmeyer-style, that is clamped or placed on an orbital shaker so a liquid culture is kept moving and exchanges gas with the air above it. Baffled versions add indentations to the flask wall to improve mixing and oxygen transfer, and most carry a vented cap that lets gas in and out while keeping microbes out. This page is about the laboratory vessel, not the drinking-bottle “protein shaker”.
Researchers and technicians who grow microbial or cell suspensions use shaker flasks. The sections below cover how the flask is built, the types and sizes that vendors document, what the sources say about fill volume, and the handling points that come from manufacturer notes.
What is a shaker flask?
A shaker flask is a flask used to grow a liquid culture on a shaker. In a 2015 article in Genetic Engineering and Biotechnology News, Daniel Bruecher of Infors HT explains why shaking matters: it suspends the cells and enlarges the liquid surface, which improves gas transfer, whereas an unshaken culture runs out of oxygen at the bottom. The same article notes that the Erlenmeyer flask became the standard choice largely because it was already available in the lab, and that a Fernbach-style flask, dating from around 1900, offers a larger liquid surface and better oxygen transfer but takes more space for the same volume.
The purpose is practical: a shaker flask gives an aerobic culture enough gas exchange to grow at benchtop scale without a stirred or aerated bioreactor. If you are comparing flasks with the instrument that moves them, the orbital shaker guide covers the platform and the incubator shaker guide covers units that add temperature control. A plain conical flask is described on its own page: what is an Erlenmeyer flask.
How a shaker flask is built
Three features distinguish a shaker flask from an ordinary laboratory flask: baffles, a vented closure and a material chosen for the work.
Baffles
Chemglass describes its glass shake flask as having three baffles on the lower outside edge of the flask. The company states that the baffles “maximize oxygen transfer to the culture medium” when the flask is used on an orbital shaker. Bruecher’s article in GEN likewise lists baffles in the bottom of the flask among the design features that give excellent mixing of the culture liquid.
Vented caps
The Chemglass flask is sold with a polypropylene vented cap that carries a 0.22 µm hydrophobic PTFE membrane. According to the supplier, the membrane allows sterile gas exchange while preventing contamination. The Corning baffled PETG flask listed on SelectScience uses a large vent cap for continuous gas exchange. The GEN article names a wide neck with large, efficient sterile filters on top as another design benchmark.
Materials
Two materials appear in the sources read for this page. Chemglass sells glass shake flasks (the page names them as “Glass Shake and Fernbach flasks”), and Corning lists a PETG flask that it describes as optically clear, with molded graduations. The PETG flask is supplied sterile and ready to use, with a sterility assurance level of 10-6, and is described as nonpyrogenic and free of RNase and DNase.
Types and variants of shaker flask
The table lists the variants that the sources describe, with the difference each source highlights. It is a description of documented products and design styles, not a ranking.
| Type | Typical use (as described by the source) | Key difference | Source |
|---|---|---|---|
| Baffled glass shake flask with vented cap | Culture on an orbital shaker, with sterile gas exchange through the cap | Three baffles on the lower outside edge; 0.22 µm PTFE membrane in a polypropylene cap; can be autoclaved with the cap attached | Chemglass |
| Baffled PETG Erlenmeyer flask, 5 L, with vent cap | Continuous gas exchange during culture | Optically clear PETG instead of glass; supplied sterile; large vent cap | Corning, via SelectScience |
| Standard Erlenmeyer flask | The traditional shaker-culture vessel, chosen because it was available in the lab | No baffles; the recommended fill level is lower than many labs use | GEN (Infors HT author) |
| Fernbach-style flask | Culture where a larger liquid surface is wanted | Larger liquid surface and better oxygen transfer, but more space needed for the same volume | GEN (Infors HT author) |
One point of terminology: suppliers write “shake flask” and “shaker flask” for the same vessel. The Chemglass product page uses “shake flasks”; this page uses both forms.
Sizes and specifications that matter
Chemglass publishes dimensions for its three-baffle glass shake flask with a GL thread and vented cap. The table repeats the values on the product page: the nominal volume, the neck thread (which decides which cap fits), and the approximate outer diameter and height.
| Nominal volume | Thread | Approx. outer diameter × height |
|---|---|---|
| 125 mL | GL-32 | 65 × 120 mm |
| 250 mL | GL-45 | 80 × 125 mm |
| 500 mL | GL-45 | 100 × 170 mm |
| 1000 mL | GL-45 | 130 × 215 mm |
| 2000 mL | GL-45 | 170 × 270 mm |
The same page lists a replacement vented polypropylene cap for the GL-45 thread, so a 125 mL flask (GL-32) and the larger sizes (GL-45) do not share a cap. The Corning PETG flask is a 5 L vessel and sits outside this range. Outer diameter and height matter in practice because the flask has to fit the clamp or platform of the shaker you own; that fit is a property of your instrument and should be checked against its documentation.
How much liquid to put in a shaker flask
The sources disagree on the exact fill level, which is itself useful information. The common ground is that a lower fill gives better oxygen transfer for aerobic cultures because the liquid surface is larger relative to the volume, and that the price of a lower fill is less culture per flask. The data table at the end of this page sets the published statements side by side.
- Bruecher in GEN (2015): a 30% filling volume should never be exceeded for Erlenmeyer flasks; many labs fill to 50% of nominal volume, which he considers a poor choice for aerobic cultures; for maximum oxygen transfer the fill can drop to about 10%, with shaking speed raised as far as shear stress and shaker limits allow.
- Infors HT blog, “The 7 deadly sins of shake flask culture”: the usual filling volume for standard Erlenmeyer flasks is between 20% and 40%, oxygen transfer is better at 10-15%, and filling beyond 25% handicaps growth of aerobic cultures; its conclusion is to fill flasks to a maximum of 20% of total volume, with high-density cultures noted as an exception.
Both articles come from the same company, so they are one vendor’s view rather than independent confirmation, and the Infors blog is internally inconsistent (a 20-40% “usual” range alongside a 20% maximum). Treat the figures as a range to start from and confirm against your own protocol and strain.
Worked example: what the percentages mean in millilitres
This is arithmetic applied to the nominal volumes in the size table, not a recommendation for any organism. For a 250 mL flask, 10% is 25 mL, 20% is 50 mL, 30% is 75 mL and 50% is 125 mL. For a 1000 mL flask the same percentages give 100 mL, 200 mL, 300 mL and 500 mL. Bruecher’s point is that the difference between the 30% ceiling and the common 50% practice is a large part of the flask’s volume, and the aerobic culture in the extra liquid is the part that runs short of oxygen.
How to choose a shaker flask
Only criteria that the sources state are listed here.
- Oxygen demand. Baffles are described by Chemglass and by the GEN article as a way to improve mixing and oxygen transfer; a Fernbach-style flask is described as giving better oxygen transfer than a standard Erlenmeyer, at the cost of space.
- Closure. A vented cap with a 0.22 µm hydrophobic membrane is the documented way to keep gas exchange open and the culture sterile. Chemglass warns that its glass Shake and Fernbach flasks are not designed for a solid screw cap for anaerobic culture and recommends pressure-resistant bottles, flasks or tubes for that purpose.
- Material and sterility status. Glass can be autoclaved with the vented cap on (Chemglass); the Corning PETG flask is offered sterile and ready to use. See the autoclave sterilization temperature guide for sterilisation parameters.
- Size and thread. Nominal volume sets the working volume once you apply the fill level; the neck thread (GL-32 or GL-45 in the Chemglass range) sets which cap fits.
Safe use and handling basics
- Use a cap that suits the culture. Vented caps are for aerobic gas exchange; the Chemglass note on solid screw caps applies to anaerobic culture and glass shake flasks specifically.
- When the manufacturer states that the flask can be autoclaved with the vented cap attached (Chemglass does, for its product), follow that instruction rather than sealing the cap, because a vented cap is what allows that. Check the instructions for your own flask and cap before autoclaving.
- Match the flask to the shaker. Dimensions in the size table are approximate, so confirm that the flask fits the clamp or platform of your instrument.
- For background on growing microbial cultures in the lab, see culturing microorganisms.
Common mistakes with shaker flasks
- Overfilling. Both sources identify filling too high as a limiter of aerobic growth, and the GEN article names 50% of nominal volume as common laboratory practice.
- Expecting a new flask to fix everything. Bruecher notes that simply replacing traditional flasks with improved designs may not be enough: gains can also need higher shaking speeds and possibly medium supplementation, and shear stress can limit how fast a culture can be shaken. His figures for improved flasks are vendor-reported.
- Using a solid cap on a glass shake flask for an anaerobic culture. Chemglass states that its glass Shake and Fernbach flasks are not designed for this.
- Mixing up the neck threads. A GL-32 flask and a GL-45 cap are not interchangeable; the Chemglass range uses both.
- Searching only the bare term. “Shaker flask” also brings up drinking bottles; add “laboratory”, “baffled” or “Erlenmeyer” when looking for the lab vessel.
Sources
- Chemglass Life Sciences: Shake Flasks, 3 Baffles, GL Thread, Vented Cap, checked 2026-11-17
- Genetic Engineering and Biotechnology News: Evolution of Shake Flask Technology (D. Bruecher, 2015), checked 2026-11-17
- Infors HT: The 7 deadly sins of shake flask culture, checked 2026-11-17
- SelectScience: Corning 5 L baffled PETG Erlenmeyer flask with vent cap, checked 2026-11-17
Data: Published fill-volume statements for aerobic shake flask culture, by source
Fill-volume recommendations for Erlenmeyer-type shake flasks, compiled from two vendor-authored sources (a 2015 GEN article by an Infors HT product manager and an Infors HT blog post). Each row restates one published statement as a percentage of nominal flask volume, with the purpose the author gives. The sources disagree, so the rows are kept separate rather than averaged.
| Statement | Source | Lower bound (% of nominal volume) | Upper bound (% of nominal volume) | Purpose or context given |
|---|---|---|---|---|
| General ceiling for Erlenmeyer flasks | GEN, Bruecher (2015) | 0 | 30 | 30% should never be exceeded |
| Common laboratory practice criticised by the author | GEN, Bruecher (2015) | 50 | 50 | Considered a poor choice for aerobic cultures |
| Fill level for maximum oxygen transfer | GEN, Bruecher (2015) | 10 | 10 | Shaking speed raised as far as shear stress and shaker limits allow; reduces culture volume |
| Usual filling volume for standard Erlenmeyer flasks | Infors HT blog | 20 | 40 | Described as usual practice |
| Fill level with better oxygen transfer | Infors HT blog | 10 | 15 | Better oxygen transfer at this level |
| Level beyond which aerobic growth is handicapped | Infors HT blog | 25 | 25 | Filling beyond 25% handicaps aerobic cultures |
| Stated maximum | Infors HT blog | 0 | 20 | Conclusion: fill to maximum 20% of total volume; high-density cultures are an exception |
Sources
- Genetic Engineering and Biotechnology News: Evolution of Shake Flask Technology (accessed 2026-11-17)
- Infors HT: The 7 deadly sins of shake flask culture (accessed 2026-11-17)
Compiled by CASRAI from the sources above. Free to reuse under CC BY 4.0 with attribution.







