Skip to main content
v2026.11,986 entries · CC-BY 4.0

Editorial · CASRAI · AI and ML research outputs

FDA Clears DeepHealth AI Tool for Five-Year Breast Cancer Risk Prediction From 3D Mammograms

The FDA has cleared DeepHealth’s Mammo Risk software, the first AI tool predicting five-year breast cancer risk directly from routine 3D mammogram scans.

Medically reviewed byDr. Diana Nieves Castro, MD
Published 25 Nov 2026· Last updated 25 Nov 2026· 7 minute read
A 3D digital breast tomosynthesis mammography imaging system in a clinical women imaging suite
Photo: USDAgov / Wikimedia Commons, Public domain (cropped). Source

The U.S. Food and Drug Administration has granted 510(k) clearance to DeepHealth for Mammo Risk, making it the first artificial intelligence tool cleared to predict three-, four-, and five-year breast cancer risk directly from routine 3D digital breast tomosynthesis mammograms, establishing a major milestone for clinical radiology practices, cancer epidemiology researchers, and academic medical centers seeking objective, image-based risk stratification.

Medical review notice: This clinical and regulatory news report has been medically reviewed by Dr. Diana Nieves Castro, MD. This page describes medical device clearance, clinical trial evidence, and health informatics workflows; it is not medical advice.

FDA Clearance of Image-Based Multi-Year Breast Cancer Risk AI

On November 24, 2026, DeepHealth, Inc., the health informatics subsidiary of national imaging operator RadNet, Inc., announced that the U.S. Food and Drug Administration granted 510(k) clearance for its Mammo Risk software application under regulatory submission K262709, decided on November 23, 2026. The clearance establishes Mammo Risk as the first regulatory-cleared software that extracts multi-year future breast cancer risk directly from completed 3D digital breast tomosynthesis (DBT) screening scans and combined 2D and 3D imaging studies without requiring supplemental radiation exposure, intravenous contrast, or specialized scanning protocols.

Traditional clinical approaches to breast cancer risk assessment depend on questionnaire-based calculators such as the Tyrer-Cuzick (IBIS) algorithm, the Gail model, or the Claus model. While widely utilized across clinical guidelines, conventional risk models require patient-reported family pedigrees, reproductive histories, and past biopsy findings—data that are frequently incomplete in high-volume screening settings. DeepHealth designed Mammo Risk to derive quantitative predictive scores directly from imaging pixels that reflect underlying biological parenchyma and radiographic density patterns captured during routine mammography.

“At DeepHealth, we believe every woman deserves a clearer, non-invasive, more predictive path for her future,” stated Niccolò Stefani, M.D., business and product leader of Clinical AI at DeepHealth. “By launching the world’s first and only image-based risk assessment software for 3D mammography, we are moving beyond just detecting cancer towards enabling preventive pathways. Unlocking these predictive insights directly from a routine scan means we can reduce uncertainty, giving providers and patients insights into risk, years before cancer would be diagnosed and enabling them to personalize care in a way that can truly save lives.”

Clinical Validation Cohorts and Technical Architecture

The regulatory clearance of Mammo Risk was supported by deep learning training on approximately 220,000 multi-institution mammography studies. The model evaluates complex tissue signatures and glandular architectural patterns that correlate with future oncogenic transformation.

For its pivotal premarket evaluation, investigators conducted an independent, multicenter retrospective study encompassing more than 65,000 screening mammograms collected across 10 distinct clinical imaging sites across the United States. According to regulatory filings and clinical performance analyses reported by Medical Product Outsourcing, the validation demonstrated robust predictive accuracy across broad demographic cohorts. The model maintained consistent predictive performance across women with dense breast tissue and Black women—two populations that have historically faced severe prognostic disparities, higher interval cancer rates, and diminished accuracy under questionnaire-based models.

The cleared software operates across multi-vendor imaging equipment, processing standard DICOM study files from major digital breast tomosynthesis manufacturers. To ensure data governance and seamless workflow integration, hospital imaging departments verify their systems against a formal DICOM conformance statement to streamline automated ingestion and image routing to AI inference engines.

Specification DeepHealth Mammo Risk (2026 FDA Clearance) Earlier European Generation (CE-Marked) Traditional Clinical Calculators (Tyrer-Cuzick / Gail)
FDA Regulatory Classification 510(k) Clearance (K262709) CE Mark Class IIa (EU MDR) Exempt clinical calculators / non-device calculators
Prediction Horizon 3-year, 4-year, and 5-year future risk Up to 2-year short-term risk 10-year and lifetime cumulative risk
Primary Data Input Routine 3D digital breast tomosynthesis and 2D scans 2D full-field digital mammography and 3D DBT Questionnaires, family pedigree, reproductive history
Pivotal Validation Cohort 65,000+ screening mammograms across 10 US sites 154,000+ screening cohort (Karolinska Institute) Epidemiological registries (e.g., BCSC, NHS cohorts)
Vendor Interoperability Multi-vendor DBT and synthesized 2D compatibility Multi-vendor full-field digital mammography Platform-agnostic (manual entry or EHR web forms)
Reimbursement Pathway AMA CPT Category III code (effective Jan 1, 2027) National health service screening tenders Standard preventative visit E and M codes

Regulatory Background and Precedents in AI-Enabled Mammography

The clearance marks an evolutionary turning point in how regulatory agencies evaluate artificial intelligence and machine learning software as a medical device (SaMD). Over the past decade, the FDA Center for Devices and Radiological Health cleared numerous computer-aided detection (CADe) and diagnosis (CADx) algorithms. However, prior clearances focused on concurrent detection—identifying lesions, microcalcifications, or architectural distortions present at the immediate moment of acquisition.

In contrast, predictive algorithms extrapolate long-term risk for patients whose current screening exam is negative for visible malignancy. To establish substantial equivalence under the 510(k) pathway rather than requiring a novel FDA De Novo classification, DeepHealth demonstrated that extending an image-based prediction horizon does not introduce unmanaged clinical risks when deployed as an adjunct risk assessment tool. The application built on prior European validations of DeepHealth’s two-year prediction model. In a benchmark study led by researchers at the Karolinska Institute and published in Science Translational Medicine involving more than 154,000 screening participants, the underlying technology demonstrated a 2.4-fold higher sensitivity compared with the Tyrer-Cuzick model when identifying the top 12 percent of women at highest risk eligible for supplemental MRI screening.

Clinical and Advocacy Sector Reaction

Breast cancer advocacy organizations and clinical imaging societies have closely tracked the transition from static, age-based screening guidelines toward individualized risk-adapted screening protocols. As reported by Imaging Technology News, patient advocates emphasized that static screening intervals fail to capture variable biological susceptibility.

“Everyone’s biology and breast cancer risk are different, yet too often we take a one-size-fits-all approach to screening and care. Better approaches have been long overdue,” emphasized Victoria Smart, Senior Vice President of Mission at Susan G. Komen. “Personalized approaches that help people understand their risk, make decisions about their health and get the care they need, as early as possible, reflects the innovation essential to ending deaths from breast cancer.”

Clinical radiology trade publications, including Radiology Business, highlighted that the software addresses significant operational bottlenecks in radiology practices. Radiologists frequently encounter compliance barriers under updated national breast density notification mandates, which require informing patients of their tissue density but frequently leave providers without automated pathways to determine which patients genuinely benefit from supplemental imaging.

Implications for Radiology Research, Academic Medical Centers, and Clinical Trials

The introduction of an FDA-cleared five-year image-based risk prediction tool presents wide-ranging implications for academic medical centers, clinical research coordinators, and health services investigators. For clinical trialists designing breast cancer chemoprevention or risk-reduction trials, Mammo Risk provides an automated tool to enrich trial populations. Instead of enrolling thousands of average-risk individuals and observing low event rates over extended time horizons, prospective clinical trials can use image-derived risk thresholds to enroll high-risk cohorts with higher statistical power and smaller sample sizes.

Academic radiology departments deploying predictive algorithms must establish multidisciplinary quality management and governance protocols. Investigators must implement systematic AI output verification frameworks to continuously audit algorithm calibration and ensure reproducibility across diverse patient demographics. Research offices conducting investigator-initiated diagnostic studies should align validation protocols with established ISO 20916 clinical performance study guidelines to maintain stringent clinical data integrity.

Commercial Rollout, Reimbursement Coding, and Next Steps

Following FDA clearance, DeepHealth announced immediate commercial availability of Mammo Risk for health systems, imaging center operators, and hospital networks throughout the United States. In the coming months, RadNet plans to embed Mammo Risk into its nationwide clinical operations, integrating the software into its proprietary Enhanced Breast Cancer Detection (EBCD) program across hundreds of outpatient imaging centers.

To facilitate standardized tracking and claims submission, the American Medical Association (AMA) established a dedicated Category III Current Procedural Terminology (CPT) code for image-based breast cancer risk assessment, scheduled to take effect on January 1, 2027. Category III codes enable healthcare providers and researchers to record utilization, establish clinical practice patterns, and collect real-world health economic evidence necessary for future conversion into permanent Category I CPT reimbursement codes.

DeepHealth will present clinical validation data, workflow analytics, and health equity outcomes at the Radiological Society of North America (RSNA 2026) 112th Scientific Assembly and Annual Meeting in Chicago, Illinois. Demonstrations and podium presentations will take place at Booth 1329 in the South Hall of McCormick Place, focusing on real-world evidence of risk prediction accuracy across racially diverse patient populations.

Sources

Ask CASRAI · full access

Ask about this story

Full access: large monthly usage, up to 10 source passages behind each answer, and MCP and API access for Claude Code, Codex and other CLIs. Cancel any time.

An AI assistant for research: funder rules, compliance, methods and publishing. It links the sources behind its answers and labels answers that come from a web search.

Answers draw on CASRAI's guides and dictionary plus the federal and funder documents we index: Federal Register, Grants.gov, Regulations.gov and UKRI.

Works on this site and inside Claude, Cursor and the AI tools you already use.

Everything CASRAI publishes — this page, the dictionary, the guides and the news — stays open to read, with no account and no card.

Referenced across the research world

University of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logoUniversity of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logo
  • University of Cambridge logo
  • Columbia University logo
  • Crossref logo
  • University of Edinburgh logo
  • Harvard University logo
  • University of Oxford logo
  • Princeton University logo
  • Stanford School of Medicine logo
  • University College London logo
  • ORCID logo

View CASRAI adoption →