Skip to main content
v2026.11,986 entries · CC-BY 4.0

Dry Ice SDS: Hazards, Exposure Limits and What Supplier Sheets Say

What a dry ice safety data sheet says about hazards, exposure limits, storage and disposal, and where three published sheets disagree.

Written and maintained by CASRAI Editorial Board

Published

On this page

A dry ice SDS is the safety data sheet for solid carbon dioxide (CAS 124-38-9, UN1845), and published supplier sheets agree on the physical hazards: extreme cold that can cause frostbite, and carbon dioxide vapour that is heavier than air and can displace oxygen in low or enclosed spaces. They disagree on how much of that is formally classified, so check the revision date and the regulatory format of the exact sheet your site holds.

What a dry ice SDS covers

Dry ice is solid carbon dioxide, which sublimes (turns directly to gas) at about -78 °C. A safety data sheet is the supplier’s standard hazard document for it, and the same substance is listed under several names: carbon dioxide, solid; carbon dioxide, solid or dry ice; dry ice; and, on older documents, MSDS (material safety data sheet). For search and for filing purposes these are one document type. For what the substance is and where it is used, see what dry ice is; for the contact-injury picture, see what happens if you touch dry ice.

Under the US Hazard Communication Standard, 29 CFR 1910.1200(g)(2), a safety data sheet must carry sixteen numbered sections in a fixed order, from Section 1 Identification to Section 16 Other information, including the date of preparation or last revision. The same paragraph tells employers what to do with the sheet: under (g)(8), the employer maintains copies in the workplace for each hazardous chemical and makes them readily accessible to employees during each work shift, with electronic access permitted as long as it creates no barrier to immediate access. A sheet that does not exist for the dry ice your lab receives, or that nobody on the shift can open, is the first gap an EHS review should close.

This page is about the carbon dioxide solid sheets. Cylinder and bulk gas sheets are a different document with different storage and pressure content; they are covered in the carbon dioxide SDS guide.

Reading a dry ice SDS section by section

Not all sixteen sections carry equal weight for a laboratory. The ones that decide how dry ice is received, stored and used are Sections 2, 7, 8, 10, 13 and 14. The statements below are taken from the Linde US sheet P-4575 (revision 05/23/2022, version 2.1), which states that it conforms to 29 CFR 1910.1200.

Section 2: hazard identification

The US sheet lists four hazard statements: may cause frostbite; may cause cryogenic burns or injury; may increase respiration and heart rate; and vapour may displace oxygen and cause rapid suffocation. Its precautionary statements include using and storing the product only outdoors or in a well-ventilated place, not handling it with bare hands, using protective gloves, not putting it in closed containers, and not entering confined areas until they are adequately ventilated.

Section 7: handling and storage

The sheet says to use tongs or insulated gloves, to store solid carbon dioxide in insulated containers that open from the top, and to keep lids loose enough that vapour from the subliming solid can escape. It states that carbon dioxide gas is about one and a half times as heavy as air and accumulates in low-lying areas, so ventilation must be adequate at floor or below-grade level. It also warns that some metals, such as carbon steel, may fracture easily at low temperature, and that skin can stick fast to very cold surfaces. The sheet describes delivery as 50-lb (22.7 kg) blocks wrapped in kraft paper, with pellets and nuggets also produced.

Section 8: exposure controls and personal protection

This is where the numbers sit. The US sheet lists an ACGIH threshold limit value (8-hour time-weighted average) of 5,000 ppm, an ACGIH short-term exposure limit of 30,000 ppm, an OSHA permissible exposure limit (8-hour time-weighted average) of 5,000 ppm and an IDLH (immediately dangerous to life or health) value of 40,000 ppm. For controls it says oxygen detectors should be used where asphyxiating gases may be released, with cold-insulating gloves for hands and safety glasses with side shields for the eyes.

Section 10: stability and reactivity

The incompatible materials listed are alkali metals, alkaline earth metals, acetylide-forming metals, chromium, titanium above 550 °C, uranium above 750 °C and magnesium above 775 °C. Electrical discharge and high temperature can decompose carbon dioxide into carbon monoxide and oxygen.

Sections 13 and 14: disposal and transport

Disposal wording is short on the US sheet: dispose of contents and container in accordance with container supplier or owner instructions. Transport information gives UN1845, carbon dioxide, solid, hazard class 9, with a reference to 49 CFR 173.140. Shipping rules sit outside the sheet itself; the dry ice shipping regulations guide and the medical specimen shipping guide cover them.

Three published sheets compared

Because the three sheets examined here describe the same substance, differences between them reveal how format, jurisdiction and age change what a reader sees. The data table below sets them side by side: the Linde US sheet (2022), the Linde Malaysia sheet (2023) and a Flinn Scientific MSDS (2010). The most useful contrasts are these.

Classification: hazard statements versus “not classified”

The US sheet carries frostbite, cryogenic-injury and suffocation hazard statements in Section 2, yet its toxicological Section 11 lists every health class (acute toxicity, skin corrosion, eye damage, sensitisation, mutagenicity, carcinogenicity, reproductive toxicity, specific target organ toxicity and aspiration) as not classified. The Malaysian sheet, prepared to that country’s 2014 Industry Code of Practice on chemicals classification and hazard communication, says “Not classified” in Section 2 and lists no other hazards. The 2010 Flinn sheet predates that vocabulary: it gives an NFPA-style at-a-glance of Health 0, Flammability 0 and Reactivity 0, while its text says skin contact may cause frostbite and blisters. An auditor who reads only the Malaysian classification line could conclude dry ice carries no hazard, which is why the physical-hazard wording in Section 7 and Section 8 matters more than the classification line.

Exposure limits

All three sheets give 5,000 ppm as the 8-hour time-weighted average. The short-term values differ. The US sheet lists the ACGIH STEL at 30,000 ppm. The Malaysian sheet lists a United Kingdom workplace exposure limit short-term value of 15,000 ppm and 30,000 ppm for New Zealand and ACGIH. The Flinn sheet prints a short-term value of 3,000 ppm, which conflicts with the 30,000 ppm figure on the other sheets; a printed value like this should be checked against a current source before it is used.

Incompatibilities

The US sheet lists specific metals. The Malaysian sheet says “None” and refers the reader to ISO 11114 for compatibility information. The Flinn sheet carries no incompatibles list but notes that dusts of various metals are ignitable and explosive when suspended in carbon dioxide. A lab that wants the most conservative picture should read the longest list rather than the shortest.

Storage and disposal wording

Here the Malaysian sheet is the odd one: its handling and storage text uses compressed-gas container language, with valve guards and caps, containers stored upright and secured, and containers kept below 50 °C, while its disposal section tells the reader to return unused product in the original container to the supplier and to avoid discharge to atmosphere in large quantities. That wording suits cylinders, not a polystyrene box of pellets. The US sheet addresses the solid directly (insulated, top-opening containers with loose lids), and the Flinn sheet says to store in a vented cooler in a well-ventilated area and to dispose by placing it in an open container in a fume hood or outdoors to sublimate. For solid dry ice in a laboratory, the US and Flinn wording describes the situation more accurately, and any local rule your institution has adopted should be written against the physical form, not against whichever sheet happens to be in the binder.

Where it matters for labs and EHS officers

Match the sheet to the product you receive

The US sheet names the forms nuggets, pellets and blocks, and its trade names include Dry Ice and UltraIce. The sheet that names the product and supplier as received, with its revision date, is the one that describes that product; a generic carbon dioxide sheet may describe the gas instead. Cylinder and dry ice sheets are separate documents.

Checklist for an SDS review

  • Is the sheet in the 16-section format, with a revision date in Section 16 or the header?
  • Does Section 2 or Section 7 state the cold-contact hazard and the oxygen-displacement hazard, whatever the classification line says?
  • Do the exposure limits in Section 8 agree with the other sheets you hold (5,000 ppm TWA is the common figure above)?
  • Does the storage text describe a vented insulated container for solids, rather than cylinder handling?
  • Does the disposal text say what to do with unused solid (supplier instructions, or sublimation in a ventilated space)?
  • Is the document readily accessible to staff on each shift, as 29 CFR 1910.1200(g)(8) requires?

The common thread in all three sheets is ventilation and avoiding enclosed spaces. The US sheet advises oxygen detectors where asphyxiating gases may be released, and the precaution of not putting dry ice in closed containers appears in both the US precautionary statements and in the Flinn advice to use a vented cooler.

Common misunderstandings

“Not classified” does not mean “no hazard”

The Malaysian sheet and the health classes in the US Section 11 show “not classified”, while the US Section 2 carries frostbite and suffocation hazard statements for the same material. Classification is a formal output of a regulatory system; hazard statements and handling text describe how the product actually injures people.

An old MSDS is not the same as a current SDS

The Flinn document is a 2010 MSDS. It is not in the 29 CFR 1910.1200 sixteen-section SDS format of the US sheet and is more than ten years older. Use it to see how wording changed, and rely on a sheet from your own supplier for current compliance.

The short-term limit is not one number

Different bodies list different short-term values (15,000 ppm UK, 30,000 ppm ACGIH and New Zealand on the sheets above), so a quoted limit needs its issuing body and country attached.

Disposal text is supplier-specific

One sheet defers to the supplier, one says return unused product, one says sublimate in a hood or outdoors. They are not interchangeable instructions, and a laboratory should follow the supplier or institutional rule that applies to the product it actually holds.

Sources

Data: Dry ice (solid carbon dioxide) SDS comparison: Linde US 2022, Linde Malaysia 2023, Flinn MSDS 2010

Side-by-side comparison of what three published safety data sheets for solid carbon dioxide say about format, classification, exposure limits, incompatibles, storage and disposal. Compiled by CASRAI from the three sheets listed as sources, each read in full text; cells restate the sheet wording in shortened form.

Period covered: Sheet revisions 2010, 2022 and 2023.

Dry ice (solid carbon dioxide) SDS comparison: Linde US 2022, Linde Malaysia 2023, Flinn MSDS 2010
AttributeLinde US P-4575 (rev 05/23/2022)Linde Malaysia (rev 03/04/2023)Flinn MSDS 212.50 (rev 09/27/2010)
Regulatory formatStates conformity to 29 CFR 1910.1200 (US Hazard Communication)Industry Code of Practice on chemicals classification and hazard communication (2014)Older MSDS layout; no regulation cited in the text read
Section 2 classification and hazard wordingHazard statements: may cause frostbite; cryogenic burns or injury; may increase respiration and heart rate; vapour may displace oxygen and cause rapid suffocationNot classified; other hazards: noneNFPA-style Health 0, Flammability 0, Reactivity 0; text says skin contact may cause frostbite and blisters
8-hour TWA exposure limit5000 ppm (ACGIH, OSHA PEL)5000 ppm (Malaysia, Germany, UK, ACGIH, New Zealand)5000 ppm
Short-term exposure limit30000 ppm (ACGIH)15000 ppm (UK WEL); 30000 ppm (New Zealand, ACGIH)3000 ppm as printed (conflicts with 30000 ppm elsewhere)
Incompatible materialsAlkali metals, alkaline earth metals, acetylide-forming metals, chromium, titanium above 550 C, uranium above 750 C, magnesium above 775 CNone; refers to ISO 11114No list; notes dusts of various metals are ignitable and explosive when suspended in carbon dioxide
Storage wordingInsulated containers opening from the top; loose lids; ventilation at floor or below-grade levelCompressed-gas container wording: valve guards, upright and secured, below 50 C, well ventilatedVented cooler in a well-ventilated area
Hand and eye protectionCold-insulating gloves; safety glasses with side shields; tongs or insulated gloves for handlingWorking gloves, EN 388 level 1 or higher; safety glasses with side shields (EN 166)Chemical splash goggles, chemical-resistant gloves, chemical-resistant apron
Disposal wordingIn accordance with container supplier or owner instructionsContact supplier; return unused product in original container; avoid large discharge to atmospherePlace in an open container in a fume hood or outdoors and allow to sublimate

Sources

Compiled by CASRAI from the sources above. Free to reuse under CC BY 4.0 with attribution.

Follow CASRAI

Research-administration guidance, standards updates and independent tool reviews.

Ask CASRAI · full access

Ask about Dry Ice SDS: Hazards, Exposure Limits and What Supplier Sheets Say

Full access: large monthly usage, up to 10 source passages behind each answer, and MCP and API access for Claude Code, Codex and other CLIs. Cancel any time.

An AI assistant for research: funder rules, compliance, methods and publishing. It links the sources behind its answers and labels answers that come from a web search.

Answers draw on CASRAI's guides and dictionary plus the federal and funder documents we index: Federal Register, Grants.gov, Regulations.gov and UKRI.

Works on this site and inside Claude, Cursor and the AI tools you already use.

Everything CASRAI publishes — this page, the dictionary, the guides and the news — stays open to read, with no account and no card.

Referenced across the research world

University of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logoUniversity of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logo
  • University of Cambridge logo
  • Columbia University logo
  • Crossref logo
  • University of Edinburgh logo
  • Harvard University logo
  • University of Oxford logo
  • Princeton University logo
  • Stanford School of Medicine logo
  • University College London logo
  • ORCID logo

View CASRAI adoption →