Skip to main content
v2026.11,986 entries · CC-BY 4.0

Griess Assay: How the Nitrite Test Works, Kits and Pitfalls

Griess assay explained: nitrite as a nitric oxide proxy, how two kit formats differ, when nitrate reduction is needed, and sample pitfalls.

Written and maintained by CASRAI Editorial Board

Published

On this page

The Griess assay is a colorimetric test that measures nitrite (NO₂⁻) in a liquid sample. Nitrite reacts with sulfanilamide under acidic conditions to form a diazonium salt, which couples with N-1-naphthylethylenediamine (NED) to give a pink-to-magenta azo dye read at about 540 nm. Because nitric oxide (NO) is too short-lived to measure directly in most biological samples, researchers use nitrite as an indirect readout of NO production, for example in cell culture supernatants.

Short answer: what the Griess assay does and does not tell you

The assay reports nitrite concentration in micromolar units, read against a standard curve prepared in the same matrix as the samples. It does not measure NO itself, and on its own it does not capture nitrate, the other stable NO breakdown product. If the experimental question is total NO production, the sample needs a nitrate-reduction step first, and the assay is then reported as nitrite plus nitrate (often written NOx). This page compares two commercial kit formats, explains when nitrate reduction is needed, and lists the sample-preparation steps most likely to spoil a result. The instrument side (reading absorbance in a 96-well plate) is covered in what a plate reader is and absorbance (optical density). This page describes a research-use laboratory method and is not clinical or diagnostic guidance.

Definition and scope

The diazotization reaction at the core of the assay was first described by Griess in 1879, according to Promega’s technical bulletin for its Griess Reagent System (TB229). Sun and colleagues, writing in Sensors in 2003, describe the same chemistry: nitrite and sulfanilamide react in acid to form a diazonium salt, the salt couples with NED to form a stable azo compound with an absorbance maximum near 540 nm, and absorbance is linear with nitrite concentration.

Why nitrite? NO has a half-life in a biological matrix that Sun and colleagues put at less than a second in the presence of haemoglobin to roughly 30 seconds, and it is rapidly oxidised to nitrite and nitrate. Bryan and Grisham (2007), reviewing methods to detect NO and its metabolites, likewise state that because NO has an extremely short half-life, its metabolites are what gets quantified, and they note that plasma or blood levels alone may not reflect tissue NO status. Promega describes nitrite as one of two primary, stable and nonvolatile breakdown products of NO. The assay therefore measures an accumulated metabolite, not a real-time NO signal.

Typical matrices named in the Promega bulletin are plasma, serum, urine and tissue culture medium. Promega’s stated detection limit is 2.5 µM (125 pmol) nitrite in ultrapure water, and it adds that sensitivity depends on the matrix. Cell Signaling Technology’s datasheet for its Griess Reagent Nitrite Measurement Kit (#13547) makes the same point: micromolar amounts of nitrite can be detected, with the range depending on the matrix or buffer. Both products are labelled for research use only; the CST datasheet states that its kit is not for diagnostic use.

How the assay is run in practice

The chemistry in two steps

Sulfanilamide diazotizes nitrite in an acidic medium (Promega’s reagent uses phosphoric acid). The diazonium product then couples with NED to form the coloured azo compound. Promega notes that purple or magenta colour forms immediately, that the colour may fade, and that plates should be read within 30 minutes through a 520 to 550 nm filter.

Standard curve

Both vendors call for a nitrite standard curve in every assay. In the Promega protocol the 0.1 M nitrite stock is diluted 1:1000 to 100 µM, then diluted in six serial twofold steps to give 100, 50, 25, 12.5, 6.25, 3.13 and 1.56 µM, plus a 0 µM blank. The bulletin specifies that the curve should be prepared in the same matrix or buffer as the samples, because interfering substances give different sensitivity in different media. Its Figure 2 shows separate curves for water, RPMI 1640 containing serum and phenol red, bovine plasma, calf serum and human urine, which makes the matrix effect visible rather than theoretical. The CST datasheet uses the same 100 to 1.56 µM range.

Layout in a 96-well plate

Promega’s protocol uses 50 µl of sample or standard in a flat-bottom 96-well plate, followed by 50 µl of sulfanilamide solution and then 50 µl of NED solution. CST’s protocol uses 100 µl of sample or standard plus 100 µl of a working reagent. Converting absorbance to concentration follows the same logic as other colorimetric plate assays, as set out in the Bradford standard-curve guide.

Sequential versus premixed reagent formats

The two kits examined here differ in how the two reagents are delivered, and that difference is the most practical thing to check before running a plate. The data table below sets the parameters side by side.

  • Sequential addition (Promega G2930). Sulfanilamide goes into the well first and is incubated for 5 to 10 minutes at room temperature, protected from light; NED is then added and incubated for another 5 to 10 minutes. Promega explains the reason: sulfanilamide and NED compete for nitrite, so adding them together can reduce the signal.
  • Premixed working reagent (CST #13547). Reagent A (sulfanilamide) and reagent B (NED) are mixed in equal volumes to form a working reagent, and 100 µl of that mix is added to 100 µl of sample or standard in each well.

Sun and colleagues compared the variants in the literature: premixed sulfanilamide plus NED, NED added 10 minutes after sulfanilamide, and sequential addition. They report sequential addition as the most popular, giving the highest chromophore yield and being used in most commercial kits. The practical consequence is that results from two kits are not interchangeable by default: reagent order, volume and read wavelength all differ, so use the standard curve supplied with the kit that generated the data and do not pool absorbance values across formats.

Storage matters too. Promega specifies 2 to 10 °C, protected from light, with the components kept separate, because shelf life drops substantially if the reagents are mixed. The kit contains 1,000 reactions (two 25 ml bottles each of sulfanilamide and NED, and 1 ml of 0.1 M nitrite standard); the CST kit is sized for 500 assays.

Nitrite versus total NOx: when nitrate reduction is needed

CST’s datasheet states that estimating total NO produced requires measuring both nitrite and nitrate, and that nitrate should first be reduced using a nitrate reductase. Sun and colleagues describe the underlying logic: nitrate is measured by running a sample with and without a reducing agent, and the difference is nitrate. The reduction methods they review each carry a caveat.

Approach What it does Caveat reported by Sun et al. (2003)
Griess alone Measures nitrite only Does not include nitrate; NO’s stable products are nitrite and nitrate, so nitrite alone can understate total NO
Copperized cadmium reduction Reduces nitrate to nitrite before the Griess reaction Cadmium is toxic
Bacterial nitrate reductase Enzymatic reduction of nitrate to nitrite, using NADPH NADPH and NADP⁺ interfere with the Griess reaction, handled with recycling systems such as lactate dehydrogenase or glucose-6-phosphate dehydrogenase; batch variation and incomplete reduction at high concentrations are noted
Zinc reduction Reduces nitrate Described as too reactive, because it reduces nitrite further

For a typical cell-culture experiment the decision is therefore a design question rather than a technique question: if the claim is “this treatment changed nitrite in the supernatant”, Griess alone supports it; if the claim is “this treatment changed NO production”, report nitrite plus nitrate or state the limitation. The CST datasheet’s own worked example is RAW 264.7 supernatants with and without interferon-γ and LPS stimulation for 48 hours; the cell line and its handling are covered in the RAW 264.7 culture guide. A different test with a similar name, the microbiological nitrate reduction test, is a different test with a similar name and answers a different question.

Sample preparation and interference checklist

The checklist below consolidates the pre-analytical points stated in the three sources. Each item is attributed to a source in the Sources section.

  1. Match the matrix. Prepare the nitrite standards in the same buffer or medium as the samples (Promega TB229). Different matrices give different sensitivity.
  2. Run a standard curve on every plate or assay (Promega TB229; CST #13547).
  3. Add sulfanilamide before NED in sequential kits, and respect the stated incubation times, room temperature and light protection (Promega TB229).
  4. Read within 30 minutes of colour development because the colour may fade (Promega TB229).
  5. Deproteinize plasma and serum before the assay (Sun et al. 2003). Acid protein precipitation causes nitrite loss and should be avoided at any cost; the authors list Carrez reagents, zinc sulfate with NaOH, centrifugal membrane filters, and methanol or diethyl ether as alternatives. They report that zinc sulfate removes about half of protein and Carrez about 85 percent, and that centrifugal filtration takes one to three hours for plasma or serum without diluting the sample.
  6. Know the interferents. Sun et al. list ascorbate, reduced thiols and phosphate among compounds that interfere with the Griess reaction; N-G-nitro-L-arginine and heparin are named for enzyme-based assays.
  7. Run spike-recovery for each new sample type: add a fixed amount of nitrite (and nitrate, if reducing) and calculate percent recovery (Sun et al. 2003). Dilute samples if NOx is high.
  8. Look for nitrate contamination. The same paper lists anticoagulants, some culture media that contain nitrate, labware (tubes, tips, ultrafiltration membranes) and dust as contamination sources.

Common misunderstandings

“A positive Griess result means NO was produced.”

Nitrite is an indirect marker. Bryan and Grisham note that circulating levels may not reflect tissue NO status, and in culture the medium itself may contain nitrate or nitrite, which is why a medium-only control belongs in every plate.

“All Griess kits give the same numbers.”

Sun and colleagues observe that, at the time of their paper, no systematic cross-vendor comparison of kits existed. Kits also differ in reagent order and volume, as the data table shows, so values should be interpreted against each kit’s own standard curve.

“The colour is stable, so plates can wait.”

Promega advises reading within 30 minutes because the colour may fade, even though Sun et al. describe the azo compound as stable under assay conditions. Follow the kit bulletin.

Frequently asked questions

What does the Griess assay measure?

Nitrite in a liquid sample, through a two-step diazotization reaction that produces a pink azo dye read near 540 nm (Sun et al. 2003; Promega TB229). It is used as an indirect measure of NO.

Can the Griess assay measure nitrate?

Not directly. Nitrate must first be reduced to nitrite, for example with nitrate reductase as recommended in the CST datasheet, and the nitrate value is then calculated as the difference between the reduced and unreduced sample (Sun et al. 2003).

What wavelength is used?

Promega specifies a 520 to 550 nm filter and CST specifies 550 nm; Sun et al. give an absorbance maximum of 540 nm.

What is the detection limit?

Promega states 2.5 µM (125 pmol) nitrite in ultrapure water, and notes that sensitivity depends on the matrix. CST gives no single figure, stating only that micromolar nitrite is detectable and the range depends on the matrix.

Why add the two reagents separately?

Promega states that sulfanilamide and NED compete for nitrite, so sulfanilamide is added first and NED second. CST instead premixes the reagents as a working reagent, so follow the instructions of the kit in use.

Can the assay be used on plasma or serum?

Both Promega and Sun et al. list plasma and serum as matrices, but Sun et al. state that deproteinization is needed and that acid precipitation loses nitrite.

Sources

  • Promega Corporation. Griess Reagent System, Technical Bulletin TB229 (G2930), rev. 10/24. https://promega.com/~/media/files/resources/protocols/technical%20bulletins/0/griess%20reagent%20system%20protocol.pdf (read 2026-11-15)
  • Cell Signaling Technology. Griess Reagent Nitrite Measurement Kit #13547, datasheet rev. 09/30/20. https://media.cellsignal.com/pdf/13547.pdf (read 2026-11-15)
  • Sun J, Zhang X, Broderick M, Fein H. Measurement of nitric oxide production in biological systems by using Griess reaction assay. Sensors 2003;3(8):276-284. https://www.mdpi.com/1424-8220/3/8/276 (read 2026-11-15)
  • Bryan NS, Grisham MB. Methods to detect nitric oxide and its metabolites in biological samples. Free Radic Biol Med 2007;43(5):645-657. doi:10.1016/j.freeradbiomed.2007.04.026, PMID 17664129 (abstract read 2026-11-15)

Data: Griess assay kit formats: Promega G2930 vs Cell Signaling #13547

Side-by-side of the published protocol parameters of two commercial Griess nitrite kits, compiled from the Promega TB229 technical bulletin and the Cell Signaling Technology #13547 datasheet, both read on 2026-11-15. Values are as stated by each vendor for its own kit and are not a performance comparison.

Griess assay kit formats: Promega G2930 vs Cell Signaling #13547
ParameterPromega Griess Reagent System (G2930)Cell Signaling Technology #13547
Reagent deliverySequential: sulfanilamide first, then NEDPremixed: reagents A and B mixed in equal volumes as a working reagent
Volume per well50 µl sample + 50 µl sulfanilamide + 50 µl NED100 µl sample or standard + 100 µl working reagent
Incubation5-10 min after each reagent, room temperature, protected from lightNot stated on the datasheet read
Read wavelength520-550 nm filter550 nm
Standard curve range100 to 1.56 µM nitrite plus 0 µM100 to 1.56 µM nitrite
Reactions per kit1,000500
Stated sensitivity2.5 µM (125 pmol) nitrite in ultrapure water; depends on matrixMicromolar nitrite; range depends on matrix or buffer
Intended useResearch; matrices include plasma, serum, urine, tissue culture mediumResearch use only, not diagnostic; example RAW 264.7 supernatants

Sources

Compiled by CASRAI from the sources above. Free to reuse under CC BY 4.0 with attribution.

Follow CASRAI

Research-administration guidance, standards updates and independent tool reviews.

Ask CASRAI · full access

Ask about Griess Assay: How the Nitrite Test Works, Kits and Pitfalls

Full access: large monthly usage, up to 10 source passages behind each answer, and MCP and API access for Claude Code, Codex and other CLIs. Cancel any time.

An AI assistant for research: funder rules, compliance, methods and publishing. It links the sources behind its answers and labels answers that come from a web search.

Answers draw on CASRAI's guides and dictionary plus the federal and funder documents we index: Federal Register, Grants.gov, Regulations.gov and UKRI.

Works on this site and inside Claude, Cursor and the AI tools you already use.

Everything CASRAI publishes — this page, the dictionary, the guides and the news — stays open to read, with no account and no card.

Referenced across the research world

University of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logoUniversity of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logo
  • University of Cambridge logo
  • Columbia University logo
  • Crossref logo
  • University of Edinburgh logo
  • Harvard University logo
  • University of Oxford logo
  • Princeton University logo
  • Stanford School of Medicine logo
  • University College London logo
  • ORCID logo

View CASRAI adoption →