Skip to main content
v2026.11,986 entries · CC-BY 4.0
LAC HealthSponsored

Shop meyerding retractor supplies

  • FDA registered
  • ISO 13485
  • BBB Accredited A+

Shop at LAC Health

Meyerding Retractor: What It Is, FDA Class and How to Read a Listing

What a Meyerding retractor is, why FDA lists self-retaining neurosurgery retractors as Class II, and what to check in a listing.

Written and maintained by CASRAI Editorial Board

Published · Last updated

On this page

General product information only, not medical advice and not a surgical technique guide.

Short answer

A Meyerding retractor is a self-retaining laminectomy retractor: a ratcheting, scissor-style instrument whose blades hold the edges of an incision apart. In FDA data, listings for it can carry product code GZT, a Class II neurosurgery code under 21 CFR 882.4800, which is not the same class as a general hand retractor.

Definition and scope

The FDA regulation for self-retaining retractors for neurosurgery, 21 CFR 882.4800, describes the device as a self-locking device used to hold the edges of a wound open during neurosurgery, and classifies it as Class II (performance standards). The FDA product code GZT is named “Retractor, Self-Retaining, For Neurosurgery” under that regulation, reviewed by the Neurology panel, and is not an implant (openFDA, data last updated 2026-10-19).

In AccessGUDID, a Markham-Meyerding self-retaining hemilaminectomy retractor from Ambler Surgical (DI 00190660139117) is described as a 6 3/4 inch instrument with a 2 1/2 inch by 1 inch wide blade on the left side, a single hook on the right side, and a ring handle with ratchet. Its GMDN term is “Laminectomy retractor, self-retaining”, described as a self-locking instrument that draws aside the margins of an incision so the lamina of the vertebral posterior arch can be excised. This page does not describe how the instrument is used in surgery.

How it is described in practice

Catalogue and regulatory records describe the instrument in a consistent set of attributes. Reading a listing means checking each one:

  • Product code and class. The Ambler GUDID record lists product code GZT, which openFDA maps to Class 2.
  • Reusable, supplied non-sterile. The same record states the device is not sterile, requires sterilization before use (moist heat or steam), and is not single-use.
  • Overall length and blade size. A Teleflex listing for Meyerding laminectomy retractors (item KM55430) shows lengths of 6 1/2 in (16.5 cm), 9 1/2 in (24.0 cm) and 10 in (25.5 cm), blade depth by width of 57.0 x 25.0, 51.0 x 25.0 and 41.0 x 25.0 mm, and a sharp distal style. The listing does not state which blade size goes with which length, so confirm the pairing on the specific item.
  • Symmetric or one-sided. The Markham-Meyerding record above has a wide blade on one side and a single hook on the other.
  • MRI labeling. The Ambler record carries no MRI safety information.

Names for the same family of instrument vary between records. The table lists the names that appear in the cited records.

Name in the record Where it appears What it shows
Meyerding laminectomy retractors Teleflex listing KM55430 Three lengths, three blade sizes, sharp distal style
Markham-Meyerding self-retaining hemilaminectomy retractor AccessGUDID, Ambler Surgical Wide blade left, single hook right, ring handle with ratchet
Laminectomy retractor, self-retaining GMDN term on the GUDID record Generic device-nomenclature name; the term’s status is listed as obsolete

Where it matters for labs, clinics and supply decisions

The name “retractor” does not determine regulatory class. The same word appears under two different FDA product codes:

Product code FDA device name Regulation Class
GZT Retractor, Self-Retaining, For Neurosurgery 21 CFR 882.4800 Class 2
GAD Retractor 21 CFR 878.4800 (general manual instruments) Class 1

Both rows are from openFDA classification data checked on 2026-10-30. So when comparing records for a retractor, compare the product code and the labeled intended use, not the instrument name. Related hand-held retractors on this site, such as the Richardson retractor and the Weitlaner retractor, are covered in their own guides; see also the overview of surgical retractors, retractor blades and neurosurgical instruments.

Common misunderstandings

  • “It arrives sterile and is single-use.” The Ambler GUDID record says the opposite: reusable and non-sterile, with sterilization required before use.
  • “All retractors are Class I.” The general Retractor code GAD is Class 1, but the self-retaining neurosurgery code GZT is Class 2.
  • “Meyerding” means one fixed size. Records show several lengths and blade sizes under the name.

FAQ

Is a Meyerding retractor Class 1 or Class 2?

A record that carries product code GZT is Class 2 under 21 CFR 882.4800. The Ambler Markham-Meyerding record lists GZT. A retractor listed under code GAD is Class 1 instead, so check the code on the specific product.

Is a Meyerding retractor sterile?

The AccessGUDID record for the Ambler Markham-Meyerding retractor says it is not sterile, is reusable, and needs steam sterilization before use. Follow the manufacturer’s instructions for use for the product in hand.

What sizes are listed?

The Teleflex listing KM55430 shows 6 1/2, 9 1/2 and 10 inch lengths with blade depth by width of 57.0 x 25.0, 51.0 x 25.0 and 41.0 x 25.0 mm; the Ambler record is 6 3/4 inches.

Sources

  • eCFR, 21 CFR 882.4800, Self-retaining retractor for neurosurgery, https://www.ecfr.gov/current/title-21/section-882.4800 (checked 2026-10-30).
  • openFDA device classification, product codes GZT and GAD, https://api.fda.gov/device/classification.json (data last updated 2026-10-19; checked 2026-10-30).
  • NLM AccessGUDID, DI 00190660139117, https://accessgudid.nlm.nih.gov/devices/00190660139117 (checked 2026-10-30).
  • Teleflex, Meyerding Laminectomy Retractors KM55430, https://us.myteleflex.com/en/USD/All-Categories/Surgical-Instruments/Orthopedic/Meyerding-Laminectomy-Retractors/p/KM55430 (manufacturer listing, checked 2026-10-30).

Follow CASRAI

Research-administration guidance, standards updates and independent tool reviews.

Ask CASRAI · free to try

Ask about Meyerding Retractor: What It Is, FDA Class and How to Read a Listing

2 free questions a day, no account.

An AI assistant for research: funder rules, compliance, methods and publishing. It links the sources behind its answers and labels answers that come from a web search.

Answers draw on CASRAI's guides and dictionary plus the federal and funder documents we index: Federal Register, Grants.gov, Regulations.gov and UKRI.

Works on this site and inside Claude, Cursor and the AI tools you already use.

Everything CASRAI publishes — this page, the dictionary, the guides and the news — stays open to read, with no account and no card.

Referenced across the research world

University of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logoUniversity of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logo
  • University of Cambridge logo
  • Columbia University logo
  • Crossref logo
  • University of Edinburgh logo
  • Harvard University logo
  • University of Oxford logo
  • Princeton University logo
  • Stanford School of Medicine logo
  • University College London logo
  • ORCID logo

View CASRAI adoption →