A Beral pipette is a disposable, single-piece liquid transfer dropper molded entirely from low-density polyethylene (LDPE), integrating a compressible suction bulb, an elongated stem barrel, and a dispensing orifice into a continuous, seamless polymer unit. Unlike traditional multi-part glass Pasteur pipettes that require attaching a separate rubber bulb, the unitary Beral pipette provides a shatterproof, chemically resistant, and biologically inert liquid handling tool designed for rapid, non-quantitative liquid transfers, slide dispensing, sample aliquoting, and microscale experimental procedures across clinical, research, and educational laboratories.
This page describes products and general use; it is not medical advice.
Who uses it: Clinical laboratory technicians, biomedical researchers, diagnostic kit manufacturers, histology specialists, and chemistry educators use Beral pipettes for safe, disposable fluid transfers where non-volumetric speed, biological inertness, and shatterproof handling are essential.
What a Beral pipette is: definition and origins
The Beral pipette represents one of the most widely used fluid-handling consumables in modern scientific practice. In laboratory terminology, it is frequently described interchangeably as an integral-bulb transfer pipette, polyethylene dropper, or disposable plastic Pasteur pipette. Structurally, the instrument consists of an enclosed, flexible upper bulb that serves as an integrated vacuum reservoir, connected seamlessly to a hollow tubular stem that terminates in a tapered dispensing tip. The entire device is manufactured from a single piece of polymer resin, eliminating mechanical joints, separate rubber bulbs, and fragile glass barrels.
The eponymous name “Beral” is the subject of a persistent misconception across academic and clinical laboratories. Many laboratory workers assume the pipette was named after an individual physician or research chemist named “Dr. Beral,” following the naming tradition of classic glassware such as the Pasteur pipette, Mohr burette, or Erlenmeyer flask. However, historical patent records and manufacturing registries confirm that the instrument is named after Beral Enterprises, Inc., a California-based medical and laboratory products company. In the mid-1970s and 1980s, inventors associated with Beral Enterprises, including Ralph F. Garren and colleagues, secured foundational patents (notably U.S. Reissue Patent US RE31555 and subsequent manufacturing patents such as US Patent 5,073,347) for thermally molding unitary plastic drop-dispensing pipettes. Over the subsequent decades, the commercial brand name became genericized across laboratory supply catalogs, scientific procurement databases, and educational curricula.
Within broader scientific liquid handling, the Beral pipette occupies a specific niche between precision volumetric instruments and crude bulk pouring. While precision tools like air-displacement micropipettes or Class A volumetric pipettes are engineered for quantitative analytical measurements with micro-liter accuracy, the Beral pipette is designed for non-quantitative fluid transfer, general specimen loading, reagent delivery, and microscale reaction handling. To understand where the Beral pipette sits across the full spectrum of laboratory pipetting equipment, researchers can consult our comprehensive overview of laboratory pipette categories, as well as our detailed analysis of transfer pipette types and selection criteria.
From a regulatory perspective in medical and diagnostic environments, disposable manual transfer pipettes used in clinical testing fall under the United States Food and Drug Administration (FDA) classification for clinical laboratory equipment. Under Title 21 of the Code of Federal Regulations (21 CFR § 862.2050), general-purpose laboratory equipment labeled or promoted for specific clinical or diagnostic procedures carries the classification product code JRC (Micro Pipette and liquid transfer apparatus). These devices are classified as Class I medical devices and are typically 510(k) exempt from premarket notification, subject to standard Current Good Manufacturing Practice (CGMP) quality controls, biological safety standards, and labeling regulations.
How Beral pipettes work and how they are built
The functional operation of a Beral pipette relies on manual elastomeric displacement and atmospheric pressure differential. When an operator squeezes the integrated polyethylene bulb, air within the internal cavity is compressed and partially evacuated through the open tip orifice. When the tip is immersed below the surface of a target liquid and compression is released, the elastic memory of the molded resin causes the bulb wall to return to its original spherical or oval geometry. This expansion creates an internal partial vacuum relative to ambient atmospheric pressure. Atmospheric pressure acting downward on the liquid surface forces fluid up through the stem into the lower barrel reservoir.
To dispense the aspirated fluid, the operator applies gentle, controlled fingertip pressure to the bulb. The fluid exit rate and droplet detachment are governed by the speed and force of compression, the inner and outer diameters of the delivery orifice, and the liquid’s physical properties, including surface tension, viscosity, and fluid density. Releasing pressure halts flow, while complete compression expels any residual liquid column.
Beral pipettes are manufactured almost universally from Low-Density Polyethylene (LDPE), a thermoplastic made from the monomer ethylene. LDPE is selected for several distinctive engineering properties that directly benefit laboratory workflows:
- Elastic memory and flexibility: LDPE exhibits a low modulus of elasticity, allowing the bulb wall to flex repeatedly under manual fingertip compression without creasing, cracking, fatigue failure, or permanent deformation.
- Biological and chemical inertness: LDPE has a non-polar, saturated hydrocarbon backbone that does not react with biological fluids, whole blood, serum, cellular suspensions, culture media, or common aqueous laboratory reagents.
- Hydrophobic surface properties: The non-wetting surface characteristics of polyethylene minimize liquid binding and meniscus distortion, resulting in exceptionally low sample retention compared to untreated silicate glass.
- Shatterproof safety: Unlike borosilicate or soda-lime glass Pasteur pipettes, LDPE is completely unbreakable under normal laboratory handling. Dropping a loaded or empty Beral pipette on a concrete or tile floor will not cause shattering, eliminating a primary source of laboratory sharps injuries and hazardous spill aerosolization.
- Thermal sealability: LDPE possesses a melting point range between 105°C and 115°C, allowing the tip or stem of the pipette to be thermally sealed using a laboratory heat sealer, thermal impulse clamp, or heated forceps. This enables the device to function as an airtight, self-contained transport vial or cryogenic storage ampoule capable of withstanding liquid nitrogen vapor storage down to -50°C.
Types and styles of Beral pipettes
Although all Beral pipettes share the foundational single-piece LDPE construction, manufacturers produce distinct physical configurations tailored to specific analytical techniques, vessel geometries, and liquid characteristics. The table below outlines the primary functional styles of Beral pipettes utilized in clinical and research facilities.
| Pipette Style | Typical Stem and Tip Geometry | Standard Working Capacity | Nominal Drop Count | Key Laboratory Applications |
|---|---|---|---|---|
| Standard General Purpose | Cylindrical stem (approx. 140–155 mm), standard tapered orifice | 3.0 to 7.5 mL total; 2.0 to 3.5 mL draw | 20 to 25 drops/mL | General reagent addition, buffer transfers, routine aliquoting, and qualitative chemistry procedures. |
| Graduated Transfer | Molded volumetric rings along the stem (0.1, 0.25, 0.5, or 1.0 mL intervals) | 1.5 to 7.0 mL total; 0.8 to 3.4 mL draw | 20 to 25 drops/mL | Rapid volumetric estimations, culture media replenishment, and non-critical reagent additions. |
| Fine Tip / Capillary | Elongated, narrow capillary tip with reduced outer diameter | 1.3 to 5.8 mL total; 1.0 to 3.4 mL draw | 45 to 60 drops/mL | Hemocytometer chamber loading, 96-well microplate dispensing, slide smears, and micro-volume titrations. |
| Extra-Long / Narrow Stem | Extended flexible barrel (225 mm to 300 mm / 9 to 12 inches) | 6.0 to 23.0 mL total; 2.3 to 10.0 mL draw | 20 to 25 drops/mL | Sampling from deep volumetric flasks, narrow-neck bottles, cylinders, and 24-hour urine collection containers. |
| Mini / Pediatric | Compact, short stem (50 mm to 115 mm length) | 1.0 to 1.5 mL total; 0.8 to 1.0 mL draw | 21 to 45 drops/mL | Microcentrifuge tube sampling, diagnostic test kits, point-of-care cartridges, and pediatric blood aliquoting. |
| Paddle / Dual Purpose | Molded flattened paddle blade at the base of the bulb or stem | 0.8 to 1.0 mL total; 0.2 to 0.3 mL draw | 20 to 25 drops/mL | Slide agglutination testing, blood typing cards, specimen stirring, and cytological smear spreading. |
| Wide-Orifice / Slurry | Wide-bore tip opening (orifice diameter 3.0 mm to 5.5 mm) | 5.0 to 7.5 mL total; 3.0 to 3.5 mL draw | 12 to 15 drops/mL | Aspirating viscous cellular aggregates, food slurries, biological homogenates, and high-molecular-weight DNA without shear damage. |
| Exact Volume Dispenser | Calibrated capillary stem with side overflow relief reservoir | 20 µL to 400 µL fixed volume | Pre-calibrated single stroke | Point-of-care lateral flow assays, field diagnostic kits, and fixed micro-volume clinical transfers. |
Each style addresses specific physical constraints at the laboratory bench. For example, standard general-purpose pipettes facilitate rapid bulk liquid movement where volume precision is secondary to throughput. Conversely, fine-tip capillary models restrict the droplet detachment mass, generating micro-droplets of approximately 16 to 22 microliters, making them indispensable for loading hemocytometer counting grids, electrophoretic sample wells, or small reaction vials without liquid overflow. The data table below compares technical parameters and dimensional specifications across several commercial models.
Sizes and specifications that matter: capacity, bulb draw, and drop counts
When selecting or utilizing Beral pipettes, laboratory personnel must evaluate three distinct volumetric parameters that are frequently conflated: total capacity, bulb draw volume, and delivered drop volume.
- Total Vessel Capacity: This figure reflects the total internal volume of the entire device, encompassing both the stem and the fully expanded bulb cavity. A pipette labeled with a total capacity of 7.5 mL cannot aspirate 7.5 mL in a single draw; that figure indicates the complete fluid volume the unit could physically hold if filled to the brim.
- Bulb Draw Volume: This measurement defines the maximum liquid volume displaced and drawn into the stem during a single, full manual compression of the bulb. For instance, a standard 7.5 mL capacity pipette typically features a bulb draw between 3.2 mL and 3.5 mL. Liquid remains within the stem and lower neck reservoir, preventing liquid from rising into the upper compression zone of the bulb where release could cause splashing.
- Graduated Increment Span: On graduated Beral pipettes, molded graduation marks are located along the stem barrel. Common graduations extend to 1.0 mL (with 0.25 mL subdivisions) or to 3.0 mL (with 0.5 mL subdivisions). These markings represent approximate volume indicators rather than analytical volumetric lines, carrying an inherent delivery variance of approximately ±5% to ±10% depending on operator technique and fluid surface tension.
- Drop Count per Milliliter (Drops/mL): The drop count specifies the nominal number of free-falling droplets delivered per milliliter of pure deionized water at 20°C when dispensed vertically at a 90-degree angle. Standard Beral pipettes deliver between 20 and 25 drops per mL (corresponding to 40 to 50 µL per drop), whereas fine-tip Beral pipettes deliver 45 to 60 drops per mL (yielding 16 to 22 µL per drop).
Mathematical drop-volume calculation and microscale titration example
In educational microscale chemistry and field diagnostic screening, Beral pipettes are frequently employed to perform drop-count titrations or micro-volume stoichiometry. To establish quantitative consistency, the nominal volume of an individual droplet (V_drop) is derived from the verified drop count per milliliter (N_drops) according to the following relationship:
V_drop (µL) = 1,000 µL / N_drops
Consider a practical laboratory scenario: A researcher is utilizing a thin-stem Beral pipette (such as the Flinn Scientific AP1444) calibrated with distilled water at 28 drops per milliliter to deliver an indicator solution into a 12-well reaction strip. Applying the formula:
V_drop = 1,000 µL / 28 drops ≈ 35.71 µL per drop
If the protocol specifies adding exactly 0.25 mL (250 µL) of reagent to each reaction well, the required drop count is calculated as:
Number of drops = 250 µL / 35.71 µL per drop ≈ 7.0 drops
Delivering 7 vertical drops from the calibrated thin-stem pipette delivers approximately 250 µL of solution with adequate precision for microscale screening. However, if the fluid viscosity or surface tension differs significantly from water—such as when handling serum, glycerol solutions, or ethanol—laboratory staff must perform an empirical bench calibration by dispensing a counted number of drops into a tared analytical balance or graduated cylinder, an approach detailed in our laboratory guide to pipette calibration intervals and methods.
Chemical compatibility and sterilization standards
Understanding the chemical resilience and thermal boundaries of low-density polyethylene is critical to avoiding specimen contamination, equipment degradation, or benchtop chemical hazards.
Polymer chemical compatibility profile
LDPE demonstrates exceptional chemical resistance against a wide range of common laboratory substances:
- Aqueous inorganic solutions: Demonstrates complete resistance to dilute and concentrated non-oxidizing acids (hydrochloric acid, dilute sulfuric acid, phosphoric acid) and concentrated alkaline solutions (sodium hydroxide, potassium hydroxide, ammonium hydroxide).
- Biological fluids and buffers: Inert in the presence of whole blood, serum, urine, cell culture media, phosphate-buffered saline (PBS), and standard tris-EDTA formulations.
- Aqueous salt solutions: Resistant to concentrated metal salts, biological staining dyes, and aqueous indicators.
- Short-chain alcohols: Compatible with methanol, ethanol, and isopropanol for short-term fluid transfers and surface sterilization.
Conversely, LDPE exhibits significant chemical vulnerabilities when exposed to non-polar organic solvents and strong oxidizing agents:
- Aromatic and chlorinated hydrocarbons: Exposure to benzene, toluene, xylene, chloroform, carbon tetrachloride, or methylene chloride causes rapid polymer absorption, swelling, softening, and structural failure. The pipette barrel becomes gummy, and low-molecular-weight polymer additives may leach into the sample.
- Strong oxidizers: Concentrated fuming nitric acid, hydrogen peroxide (>30%), and aqua regia cause surface oxidation and embrittlement over extended exposure.
- Volatile ethers and ketones: Diethyl ether and acetone cause moderate swelling and softening; high vapor pressure solvents also evaporate rapidly inside the bulb, causing fluid to drip involuntarily from the tip orifice.
Sterilization and packaging grades
Beral pipettes are supplied commercially in two primary packaging configurations based on clinical and microbiological sterility requirements:
- Non-sterile bulk packaging: Packed in bulk polybags containing 250, 400, or 500 units. These are intended for general chemistry laboratories, routine teaching classrooms, sample preparation steps that do not require asepsis, and high-throughput non-biological waste handling.
- Sterile packaging: Subjected to validated terminal sterilization via gamma irradiation or ethylene oxide (EtO) gas exposure. These are packaged either individually in peel-apart medical paper/film pouches or in multi-packs (e.g., 5, 10, or 20 pipettes per sealed pack) with certified sterility assurance levels (SAL 10^-6). Sterile units are certified free of detectable RNase, DNase, pyrogens (endotoxins), and human DNA, rendering them suitable for clinical phlebotomy processing, tissue culture transfers, molecular diagnostic specimen handling, and blood banking serology.
A critical operational rule: Beral pipettes cannot be autoclaved. Steam autoclave cycles operate at 121°C (250°F) under 15 psi pressure, which exceeds the thermal melting point of LDPE (105°C to 115°C). Autoclaving causes LDPE pipettes to melt, distort, and fuse into an unusable polymer mass.
How to choose the right Beral pipette
Selecting the optimal Beral pipette style requires evaluating four practical parameters based on the physical requirements of the assay and the container geometry:
- Match the stem length to the vessel depth: Standard 140 mm to 155 mm pipettes are designed for routine test tubes, microcentrifuge tubes, and standard 100 mL beakers. If sampling from volumetric flasks, 500 mL media bottles, or deep 24-hour urine collection containers, choose an extra-long stem pipette (225 mm to 300 mm) to reach the container bottom without submerging the non-sterile bulb or the operator’s gloves into the vessel neck.
- Match the tip orifice to the target volume and precision: For routine fluid transfers where speed is essential, standard tips (20–25 drops/mL) provide optimal flow. For microplate filling, slide droplet dispensing, or hemocytometer loading, select a fine-tip or ultra-fine capillary model (45–60 drops/mL) to prevent surface tension bridging and well cross-contamination.
- Evaluate fluid viscosity and cellular integrity: When aspirating viscous reagents, high-density microbial slurries, or delicate cellular aggregates (such as embryonic cell clusters or un-sheared high-molecular-weight genomic DNA), use wide-orifice slurry pipettes (tip diameter > 3.0 mm). Narrow standard tips generate excessive hydrodynamic shear stress, which can lyse fragile cells or fragment macromolecular DNA.
- Confirm regulatory and cleanliness requirements: For clinical diagnostic testing, blood transfusion serology, or molecular biology protocols, specify certified gamma-irradiated, individually wrapped sterile pipettes. For general chemical synthesis, education, or non-critical reagent additions, bulk non-sterile pipettes provide substantial procurement cost savings.
Safe laboratory handling and biosafety practices
Proper physical handling ensures reproducible droplet volume delivery while preventing aerosol generation, cross-contamination, and biological exposure.
Dispensing technique and droplet geometry
To achieve consistent drop volume delivery, the operator must hold the Beral pipette strictly vertical at a 90-degree angle to the receiving surface or vessel. When a pipette is held at a 45-degree angle, the liquid droplet contacts the exterior side wall of the tip before detaching, increasing the effective contact area and altering the balance between gravitational pull and surface tension forces. This can alter delivered droplet volume by 15% to 30% relative to vertical delivery. The operator should compress the bulb steadily until the droplet forms, hangs freely at the tip orifice, and falls under its own weight without touching the receiving vessel wall.
Eliminating laboratory hazards
The historical replacement of glass Pasteur pipettes with integral LDPE Beral pipettes resolved several major occupational health hazards in biological and chemical laboratories. In earlier eras of laboratory practice, technicians routinely used rubber suction bulbs fitted onto fragile glass tubes, or resorted to hazardous mouth pipetting—a practice now globally prohibited by international biosafety guidelines. The risks and clinical transmission hazards associated with legacy fluid transfer techniques are documented in our review of why mouth pipetting was banned and the technologies that replaced it.
By integrating the suction bulb directly into a flexible, shatterproof polymer structure, Beral pipettes eliminate glass puncture lacerations, avoid air leakage at bulb-stem friction junctions, and prevent fluid from accidentally being drawn past an open upper stem into a suction mechanism. Furthermore, because Beral pipettes are cost-effective single-use consumables, they eliminate the risk of cross-contamination inherent in attempting to wash and reuse narrow glass droppers.
Biohazard disposal and environmental handling
After handling biological fluids, infectious clinical specimens, viral transport media, or toxic reagents, Beral pipettes must be discarded immediately into designated biohazard sharps containers or heavy-duty biohazard solid waste receptacles. While LDPE is technically recyclable under resin identification code 4, laboratory-contaminated pipettes cannot enter municipal plastic recycling streams. Regulated medical waste containing used pipettes undergoes commercial high-temperature incineration or centralized autoclave shredding before authorized landfill deposition.
Common mistakes when using Beral pipettes
Despite their simplicity, procedural errors with Beral pipettes can compromise experimental outcomes and analytical reproducibility:
- Mistake 1: Relying on molded graduations for analytical quantification. Molded graduation marks on Beral pipettes provide only qualitative reference guides. Using a graduated Beral pipette in place of a calibrated volumetric pipette or micropipette for quantitative chemical assay formulation introduces systematic volume errors of 5% to 15%.
- Mistake 2: Inverting or tilting the pipette horizontally when loaded. Holding a filled Beral pipette horizontally or turning it upside down allows fluid to enter the upper bulb reservoir. When the bulb is compressed again, trapped liquid can trap air pockets, spray uncontrollably, create aerosol misting, or contaminate subsequent transfers.
- Mistake 3: Dispensing drops at variable or oblique angles. Dispensing reagents while tilting the pipette at varying angles between 30 and 60 degrees causes substantial droplet volume variation. Consistent drop-count protocols require maintaining a steady 90-degree vertical orientation throughout dispensing.
- Mistake 4: Attempting to autoclave LDPE pipettes for reuse. Attempting to sterilize used LDPE pipettes in a standard 121°C steam autoclave causes the polymer to soften and melt, creating an expensive cleaning problem in the autoclave chamber and destroying the pipettes.
- Mistake 5: Using Beral pipettes with non-polar organic solvents. Using LDPE pipettes with chloroform, methylene chloride, toluene, or diethyl ether causes rapid polymer swelling, sample contamination through leached oligomers, and involuntary dripping caused by solvent vapor pressure buildup inside the bulb.
- Mistake 6: Drawing fluid into the upper bulb during aspiration. Forcefully squeezing and releasing the bulb beyond the stem’s fluid capacity can draw aggressive reagents into the upper bulb chamber, making complete drainage impossible and generating trapped bubbles during dispensing.
Frequently asked questions
What is the difference between a Beral pipette and a Pasteur pipette?
A traditional Pasteur pipette consists of a hollow glass tube with a tapered tip that requires attaching an independent rubber bulb or latex dropper teat to create suction. A Beral pipette is an all-in-one, unitary transfer pipette molded from a single piece of low-density polyethylene (LDPE), incorporating an integral squeeze bulb that cannot detach or leak air.
Why is it called a Beral pipette?
The name derives from Beral Enterprises, Inc., the medical products manufacturing company that patented and commercialized unitary, thermally molded plastic drop-dispensing pipettes in the 1970s and 1980s. Over time, the corporate brand name genericized across laboratory supply catalogs to describe one-piece plastic transfer pipettes.
How many drops are in 1 mL using a Beral pipette?
A standard general-purpose Beral pipette delivers between 20 and 25 drops per milliliter of pure water, equating to a nominal drop volume of 40 to 50 microliters. Fine-tip capillary Beral pipettes deliver between 45 and 60 drops per milliliter, producing smaller micro-droplets of approximately 16 to 22 microliters.
Can Beral pipettes be autoclaved and reused?
No. Beral pipettes are manufactured from low-density polyethylene (LDPE), which has a melting point range of 105°C to 115°C. Standard steam autoclave cycles operate at 121°C, which will melt and deform the plastic. They are designed and certified as single-use disposable consumables.
How accurate are the graduation markings on a Beral pipette?
Graduation markings molded onto Beral pipette stems are approximate reference indicators intended for rough volume estimation, typically carrying an inherent uncertainty of ±5% to ±10%. They should never be used for analytical or quantitative chemistry procedures that require calibrated volumetric accuracy.
How do you heat-seal a Beral pipette for sample storage?
Because LDPE melts between 105°C and 115°C, the tip or stem of a loaded Beral pipette can be sealed by pinching it with heated laboratory forceps or pressing it against a commercial thermal impulse heat sealer. Once cooled, the sealed plastic forms a leak-tight container suitable for transport or cryogenic storage in liquid nitrogen down to -50°C.
Sources
- U.S. Food and Drug Administration (FDA) — 21 CFR § 862.2050: General purpose laboratory equipment labeled or promoted for a specific medical use (Product Code JRC, Class I, 510(k) exempt). https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfcfr/cfrsearch.cfm?fr=862.2050 (checked 2026-11-14).
- United States Patent and Trademark Office — Reissue Patent US RE31555 (Original US Pat. 3,938,392) and US Patent 5,073,347: Unitary molded plastic drop-dispensing pipettes assigned to Beral Enterprises, Inc. (Inventors: Ralph F. Garren et al.). https://patents.google.com/patent/USRE31555E/en (checked 2026-11-14).
- Globe Scientific Inc. — Technical Data Sheet and Catalog: Low-Density Polyethylene (LDPE) Transfer Pipets (Standard, Graduated, Fine Tip, Extra-Long, and Mini Specifications). https://www.globescientific.com/laboratory-supplies/pipets/transfer-pipets/ (checked 2026-11-14).
- Thermo Fisher Scientific — Samco Transfer Pipets Specification Guide and Catalog (Models 212, 222, 225, 282, Exact Volume, and Padl-Pet). https://www.thermofisher.com/order/catalog/product/212 (checked 2026-11-14).
- Flinn Scientific — Laboratory Consumables and Safety Catalog: Beral-Type Pipets (AP1444, AP1445, AP1447, AP1448) and Microscale Laboratory Protocol Standards. https://www.flinnsci.com/beral-type-pipets-thin-stem-pkg.-of-500/ap1444/ (checked 2026-11-14).
- Cole-Parmer — Disposable LDPE Transfer Pipettes Technical Specifications (Model 2525410 Large Bulb and Drop Count Benchmarks). https://www.coleparmer.com/i/cole-parmer-disposable-transfer-pipettes-ldpe-5-0-ml-large-bulb/2525410 (checked 2026-11-14).
Data: Beral and Transfer Pipette Technical Specifications by Style and Manufacturer
Comparative specifications of commercial low-density polyethylene (LDPE) Beral and transfer pipettes across leading manufacturers, compiling total capacities, bulb draw volumes, overall lengths, nominal drop counts, and primary laboratory applications.
| Style and Model | Manufacturer | Total Capacity (mL) | Bulb Draw (mL) | Total Length (mm) | Drops per Milliliter (drops/mL) | Nominal Drop Volume (uL) | Primary Application |
|---|---|---|---|---|---|---|---|
| Small Bulb Graduated (Cat 212) | Thermo Scientific Samco | 3.9 | 2.1 | 140 | 25 | 40 | General routine aqueous liquid transfer and aliquotting |
| Large Bulb Graduated (Cat 222) | Thermo Scientific Samco | 5.8 | 3.4 | 155 | 25 | 40 | General laboratory transfer and reagent dispensing |
| Graduated Large Bulb (2525410) | Cole-Parmer | 5 | 3.4 | 145 | 25 | 40 | Approximate volumetric transfer with 0.25 mL graduations |
| Thin Stem Beral Pipet (AP1444) | Flinn Scientific | 4 | 3 | 150 | 28 | 36 | Microscale chemistry, microtitrations, and reaction wells |
| Fine Tip Capillary (137035) | Globe Scientific | 5.8 | 3.4 | 153 | 50 | 20 | Hemocytometer loading, multi-well microplates, and slide smears |
| Mini Fine Tip (137015) | Globe Scientific | 1.3 | 1 | 51 | 45 | 22 | Micro-volume dispensing and pediatric diagnostic spot tests |
| Extra-Long 9-Inch (138010) | Globe Scientific | 6 | 2.3 | 225 | 25 | 40 | Reaching deep into volumetric flasks and reagent bottles |
| Extra-Long 12-Inch (138030) | Globe Scientific | 23 | 10 | 300 | 21 | 48 | Large-volume sampling from 24-hour urine collection containers |
| Extra-Large Bulb (AP1445) | Flinn Scientific | 7.5 | 3.2 | 155 | 20 | 50 | Bulk reagent aspiration and rapid solution transfer |
| Padl-Pet Dual Purpose (Cat 295) | Thermo Scientific Samco | 0.8 | 0.2 | 124 | 20 | 50 | Slide agglutination testing and biological smear spreading |
| Wide-Orifice Slurry (Cat 993) | Thermo Scientific Samco | 7.5 | 3.3 | 132 | 13 | 77 | Suspensions, viscous fluids, and fragile cellular aggregates |
Sources
- Thermo Scientific Samco Transfer Pipets Specification Guide (accessed 2026-11-14)
- Globe Scientific LDPE Transfer Pipets Technical Data (accessed 2026-11-14)
- Flinn Scientific Beral-Type Pipets Catalog (accessed 2026-11-14)
- Cole-Parmer Disposable Transfer Pipettes Technical Specifications (accessed 2026-11-14)
Compiled by CASRAI from the sources above. Free to reuse under CC BY 4.0 with attribution.