What Is an FFP3 Mask? EN 149 Class and Use

FFP3 mask explained: EN 149 filter limits vs FFP2, HSE protection factor 20, NR and D markings, and what it cannot protect against.

Written and maintained by CASRAI Editorial Board

Published · Last updated

On this page

An FFP3 mask is a European-standard filtering facepiece respirator: a disposable half mask that filters airborne particles and sits in the highest of the three EN 149 filter classes (FFP1, FFP2, FFP3). This page describes products and general use; it is not medical advice.

Who uses it: workers and staff who handle hazardous dusts, mists or biological agents under an employer’s respiratory protection programme, and the buyers and safety officers who specify that equipment.

Ask CASRAI · free to tryQuestion about this guide? Ask CASRAI answers with linked sources. 2 free questions a day, no account.

Ask your first question freeSubscribe

What an FFP3 mask is

“FFP” stands for filtering facepiece against particles. The “3” is the class with the strictest filter limits. The British Health and Safety Executive (HSE) lists FFP3 disposable half masks under standard BS EN 149 with a protection factor of 20, against 10 for FFP2 and 4 for FFP1 (HSE, HSG53, 4th edition 2013, Figure 8; read 2026-11-08). The mask body itself is the filter, so no separate cartridge is fitted.

It protects against particles only. A manufacturer datasheet (Moldex Air FFP masks, GB 03-16) states that FFP masks do not protect against gases and vapours, and that they must not be used where the contaminant is unknown, at dangerous levels, or where oxygen is below 19.5 % by volume.

How it is built

The Moldex datasheet describes FFP3 masks made from a polypropylene filter layer, EVA, a polyethylene nose seal and clip, a polyester/Lycra strap and, on valved models, a natural rubber exhalation valve. Listed weights are 26 to 30 g. Because materials vary by manufacturer, check the instructions for use (IFU) of the exact product.

FFP1, FFP2 and FFP3 compared

Class HSE protection factor (FFP1 is 4) Max. filter penetration (EN 149, per datasheet) Max. total inward leakage, 8 of 10 subjects (per datasheet)
FFP2 10 6 % 8 %
FFP3 20 1 % 2 %

Sources: HSE HSG53 Figure 8 (protection factors); Moldex Air FFP masks datasheet GB 03-16, “Testing according to EN 149:2001 + A1:2009” (penetration after loading with 120 mg paraffin oil; total inward leakage across ten test subjects).

The common “99 % versus 94 %” shorthand is a loose reading of these limits. The standard sets a maximum filter penetration and a maximum total inward leakage, and the leakage figure includes the face seal and valve, which is why fit matters as much as the filter.

What the markings mean

  • NR: not reusable. HSE guidance says to dispose of masks marked NR after a single shift (8 hours).
  • D: the mask passed the dolomite dust clogging test, per the Moldex datasheet.
  • Valved or non-valved: Moldex lists both versions in FFP3 (for example 3200 non-valved and 3205 valved in sizes M/L; 3250 and 3255 in size S). The valve is a design feature; it is the manufacturer’s IFU that states how each model is to be used.

What FFP3 is rated for

The Moldex datasheet gives FFP3 a limit of 20 times the workplace exposure limit and lists harmful and carcinogenic dusts, water- and oil-based mists and aerosols, biological agents of risk group 2 and 3, and CMR (carcinogenic, mutagenic, reproductive toxic) substances. Whether a given hazard is covered is a risk-assessment question for the employer, not something this page can decide.

Sizes

Model (Moldex) Size Valve
3200 M/L No
3205 M/L Yes
3250 S No
3255 S Yes

Source: Moldex Air FFP masks datasheet GB 03-16. Other makers use their own size ranges.

Safe use and handling basics

  • Fit testing. HSE’s table states fit testing is required for disposable half masks, by qualitative or quantitative method. See the respirator fit test guide for the US OSHA framework.
  • Wear time. HSE lists continuous wear time for disposable half masks as less than one hour at a medium work rate.
  • Replace a mask that is damaged or where breathing resistance rises because the filter has clogged (Moldex datasheet).
  • Training and no modification. The datasheet states the user must be trained and the mask must never be modified.

Common mistakes

  • Treating the class as a guarantee without a seal: leakage around the face is part of the EN 149 total inward leakage measure.
  • Using it against gases or vapours, which FFP masks do not filter.
  • Reusing an NR mask beyond a single shift.

FFP2 is the middle class, covered in What Is an FFP2 Mask?. The Korean KF94 grade is compared with N95 in What Is a KF94 Mask?. For reusable options, see half-face respirators, and for the wider category, what PPE means.

FAQ

Is an FFP3 mask better than an FFP2?

It has stricter EN 149 limits: 1 % maximum filter penetration against 6 %, and 2 % total inward leakage against 8 % (Moldex datasheet), and an HSE protection factor of 20 against 10. Both need a good face fit to deliver that.

Does an FFP3 mask protect against gases?

No. The manufacturer datasheet states FFP masks do not protect against gases and vapours.

Can an FFP3 mask be reused?

Not if it is marked NR; HSE says to dispose of NR masks after a single shift of 8 hours.

Sources

  • Health and Safety Executive, HSG53 Respiratory protective equipment at work, 4th edition 2013: hse.gov.uk/pubns/books/hsg53.htm (read 2026-11-08).
  • Moldex-Metric, Moldex Air FFP masks datasheet GB 03-16 (manufacturer document; model, size, material and marking details on this page). No stable public URL for this document could be confirmed, so check the current datasheet or product manual on the manufacturer’s site, moldex.com, before relying on model-specific details.
  • Moldex-Metric, Datasheet FFP masks, EHO-GB 06-13 (Smart series), at moldex.com (read 2026-11-08): its EN 149:2001 + A1:2009 test summary states maximum filter penetration of 6 % (FFP2) and 1 % (FFP3), and maximum total inward leakage of 8 % (FFP2) and 2 % (FFP3) for 8 of 10 test subjects.

Follow CASRAI

Research-administration guidance, standards updates and independent tool reviews.

Ask CASRAI · free to try

Ask about What Is an FFP3 Mask? EN 149 Class and Use

2 free questions a day, no account.

An AI assistant for research: funder rules, compliance, methods and publishing. It links the sources behind its answers and labels answers that come from a web search.

Answers draw on CASRAI's guides and dictionary plus the federal and funder documents we index: Federal Register, Grants.gov, Regulations.gov and UKRI.

Works on this site and inside Claude, Cursor and the AI tools you already use.

Everything CASRAI publishes — this page, the dictionary, the guides and the news — stays open to read, with no account and no card.

Referenced across the research world

University of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logoUniversity of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logo
  • University of Cambridge logo
  • Columbia University logo
  • Crossref logo
  • University of Edinburgh logo
  • Harvard University logo
  • University of Oxford logo
  • Princeton University logo
  • Stanford School of Medicine logo
  • University College London logo
  • ORCID logo

View CASRAI adoption →