Written and maintained by CASRAI Editorial Board
Published
On this page
The activated sludge process is a biological wastewater treatment process in which wastewater is mixed and aerated with a suspended culture of bacteria, called activated sludge, that consumes the biodegradable organic matter. The bacteria then settle out in a secondary clarifier. Most of the settled sludge is returned to the aeration tank to keep the culture working, and the surplus is removed as waste activated sludge.
This guide explains the loop step by step, separates the two measurements people confuse most often (MLSS and SVI) with a worked calculation, sets the process against the US secondary treatment limits in 40 CFR 133.102, and covers bulking, the main operating failure. The downloadable data table below the guide collects every number used here with its source.
Definition and scope
An EPA instructional monograph defines activated sludge as a biological wastewater treatment process in which a mixture of wastewater and biological floc is aerated so that material that would not settle is converted into material that does. The Eawag/SSWM factsheet describes the same thing from the biology side: activated sludge is suspended aerobic sludge consisting of flocs of active bacteria, which consume aerobically biodegradable organic substances from screened or pre-settled wastewater.
Two points of scope matter. First, the process only treats what bacteria can degrade; SSWM notes that activated sludge systems can handle domestic and industrial wastewater as long as the pollutants are biodegradable. Second, it is a secondary treatment step. It normally follows screening and primary settling and is sometimes followed by a polishing step such as tertiary filtration and disinfection. Treated water leaving the plant is judged by laboratory measurements such as BOD and suspended solids; for related laboratory measurements see our guides to the chemical oxygen demand test and the total suspended solids (TSS) test.
How the activated sludge process works
Taken together, the EPA monograph and the SSWM factsheet describe a closed loop with five working parts.
- Pre-treatment. Screening, and usually primary settling, remove coarse and settleable solids before the wastewater reaches the aeration tank. Extended aeration plants are the stated exception: the EPA monograph says they usually have no primary treatment.
- Aeration tank. Air or oxygen is supplied by pumping it into the tank or by surface aerators, and the contents are mixed to keep the sludge in suspension. The bacteria use the organic pollutants to grow, producing energy, water, carbon dioxide and new cells (SSWM). The mixture of wastewater and sludge in this tank is called mixed liquor.
- Secondary clarifier. The flocs are separated from the treated water by gravity settling. SSWM also notes that membrane filtration can replace settling in some designs.
- Return of settled sludge. Settled sludge is returned to the aeration tank so there is always an active culture to meet fresh wastewater. SSWM states that the rate of recirculation of settled sludge varies from 20 to 100 percent.
- Wasting of excess sludge. Growth produces more sludge than the system needs. The EPA monograph calls this excess sludge waste activated sludge; it is withdrawn and sent to further sludge treatment. SSWM lists a conventional chain of thickening, anaerobic digestion, incineration and safe disposal, and composting as a more sustainable alternative.
Operators control the balance between growth and removal rather than any single setting. The EPA monograph names food-to-microorganism ratio (F/M) and mean cell residence time (MCRT) as the control strategies in use, and states that there is no universal number for these parameters that will work for every plant. SSWM gives a related design figure: the solids retention time (SRT) in the reactor ranges from 3 to 5 days for BOD removal and from 3 to 18 days for nitrification, depending on temperature.
What are the 7 steps in wastewater treatment?
The sources used for this page do not define a fixed seven-step sequence, and the number of steps differs between textbooks and utilities. What they do agree on is the order of stages around the activated sludge unit: screening, primary settling, aeration with biological treatment, secondary clarification, return and wasting of sludge, optional tertiary polishing and disinfection, and treatment of the sludge removed. If a course, exam or permit document gives a numbered list, follow that document’s own list and use the stages here to place the activated sludge unit within it. For the drinking-water side of the same field, see drinking water treatment.
MLSS vs SVI: what is the difference?
MLSS and SVI are both measured on mixed liquor, which is why they are mixed up, but they answer different questions. MLSS (mixed liquor suspended solids) is a concentration: how many milligrams of suspended solids are in each litre of mixed liquor. SVI (sludge volume index) is a settling characteristic: how much volume one gram of those solids occupies after settling. The EPA wastewater laboratory manual defines the SVI as the volume in millilitres occupied by one gram of mixed liquor suspended solids after 30 minutes of settling, and says the test is used to indicate changes in sludge characteristics.
| Feature | MLSS | SVI |
|---|---|---|
| What it measures | Mass of suspended solids per volume of mixed liquor | Volume occupied by one gram of those solids after settling |
| Unit | mg/L | mL/g |
| Question it answers | How much biomass is in the tank? | How well does the sludge settle? |
| Needs the other? | No | Yes: SVI is calculated using MLSS |
| Source | EPA monograph (solids inventory formula) | EPA wastewater laboratory manual, Test 11 |
Worked example: solids inventory from MLSS
The EPA monograph shows how MLSS becomes a mass of solids under aeration: pounds of solids equal MLSS in mg/L multiplied by aerator volume in million gallons multiplied by 8.34. Its example uses an aeration tank measuring 100 ft by 45 ft by 16.5 ft, about 0.55 million gallons, and an MLSS of 780 mg/L. That gives roughly 3,600 pounds of solids under aeration; the monograph reports 3,588 pounds.
Worked example: SVI from settled volume and MLSS
The laboratory manual gives the calculation as SVI = (percent settleable solids × 10,000) ÷ MLSS in mg/L. For a sample whose settled sludge occupies 18 percent of the volume after 30 minutes (180 mL per litre) and whose MLSS is 1,500 mg/L, SVI = (18 × 10,000) ÷ 1,500 = 120 mL/g. The same arithmetic in plain units: 180 mL/L of settled sludge divided by 1.5 g/L of solids is 120 mL per gram. The manual also defines the sludge density index as 100 ÷ SVI, which for this example is about 0.83.
Neither number is a pass or fail by itself. Given the monograph’s point that no single control value suits every plant, compare SVI with the same plant’s own record and treat a change as a prompt to look at the sludge, not as a stand-alone verdict.
Types of sludge in an activated sludge plant
People asking what sludge is in a water treatment plant usually mean one of the streams below. In this process the word covers both the living culture that does the treatment and the surplus that has to be handled.
| Term | What it is | Where it appears | Source |
|---|---|---|---|
| Activated sludge | Suspended aerobic sludge made of flocs of active bacteria | Aeration tank and clarifier | Eawag/SSWM |
| Return sludge | Settled solids sent from the clarifier back to the aeration tank | Recycle loop | EPA monograph; SSWM |
| Waste activated sludge | The excess sludge removed from the process | Withdrawn for further sludge treatment | EPA monograph |
| Primary sludge | Sludge from the primary treatment facilities, treated together with waste activated sludge | Primary settling | Eawag/SSWM |
Sludge from either source needs further treatment before disposal or reuse. SSWM lists this as one of the disadvantages of the process: the sludge, and possibly the effluent, require further treatment or appropriate discharge.
Return rate: a worked example
The EPA monograph also shows how return flow is estimated from settling. Return rate in million gallons per day equals aerator flow multiplied by the settleable solids fraction. In its example the aerator receives 4.0 MGD of primary effluent plus 1.0 MGD of return flow, so 5.0 MGD, and the settleable solids are 18 percent (360 mL in a 2 L sample). The return rate is 5.0 × 0.18 = 0.9 MGD, about 625 gallons per minute. The monograph then notes that a rate slightly higher than the calculated one is recommended.
Process variants
SSWM lists the well-known modifications of the basic design as sequencing batch reactors, oxidation ditches, deep shafts, extended aeration, moving beds and membrane bioreactors. Three are worth knowing because they change the numbers above.
- Sequencing batch reactor (SBR). The same tank does every job in turn: SSWM describes a cycle of five stages, fill, react, settle, draw and idle, so no separate clarifier is needed.
- Oxidation ditch. A large round or oval channel with horizontal aerators. SSWM gives a typical hydraulic retention time of 24 to 48 hours with a sludge age of 12 to 20 days, and says primary sedimentation is usually not required.
- Extended aeration. According to the EPA monograph these plants usually have no primary treatment and the aeration basin is sized for an 18 to 24 hour detention period. The long aeration and high sludge age produce a nitrified effluent and a stable, partially digested sludge.
Where the process matters: effluent limits and laboratory monitoring
For US publicly owned treatment works, 40 CFR 133.102 defines the minimum effluent quality attainable by secondary treatment, and activated sludge is one of the processes plants use to meet it. For 5-day biochemical oxygen demand (BOD5) the 30-day average may not exceed 30 mg/L, the 7-day average may not exceed 45 mg/L, and the 30-day average percent removal may not be less than 85 percent. The permitting authority may allow CBOD5 in place of BOD5 at 25 mg/L (30-day), 40 mg/L (7-day) and 85 percent removal. Suspended solids carry the same 30, 45 and 85 percent figures. Effluent pH must stay between 6.0 and 9.0 unless the plant shows that it adds no inorganic chemicals and that industrial sources do not push pH outside that range.
These are minimums, and a well-run plant can do better: SSWM cites a typical high-quality activated sludge effluent at or below 10 mg/L for both BOD and TSS, and general BOD and TSS removal of 80 to 100 percent depending on influent, set-up and temperature. Whether a result meets a permit depends on the approved analytical method, and 40 CFR Part 136 governs those; see 40 CFR Part 136 test procedures and how results are reported in a discharge monitoring report. For the wider discipline these measurements belong to, see what is environmental engineering.
For laboratories supporting a plant, the practical split is straightforward. The process control tests (MLSS, settleability, SVI) are run on mixed liquor to steer the plant day to day. The compliance tests (BOD5 or CBOD5, TSS, pH) are run on final effluent to show the permit is met.
Bulking and foaming: the main operating failure
SSWM identifies two of the most serious problems with the activated sludge process: bulking, in which sludge from the aeration tank will not settle, and the development of biological surface foam. Bulking can be caused by organisms that grow in filamentous form instead of in flocs, or by microorganisms that incorporate large volumes of water into their cells so that their density is near that of water. Foaming is caused most often by excessive growth of Nocardia.
This is where SVI earns its place. A sludge that stops settling shows up as a larger volume per gram of solids, so a rising SVI is one way bulking appears in the laboratory record. SSWM lists the controls for filamentous organisms: adding chemicals such as chlorine or hydrogen peroxide to the recycled sludge, changing the dissolved oxygen concentration in the aeration tank, and adding nutrients and growth factors to favour other microorganisms. For Nocardia it lists avoiding recycling of the skimmed foam, or adding a chemical agent such as polymers or chlorine on the surface.
Advantages and limits
SSWM summarises the case for the process as resistance to organic and hydraulic shock loads, operation across a range of loading rates, high effluent quality, the possibility of nutrient removal, little land compared with natural systems such as waste stabilisation ponds, and the ability to be modified to meet specific discharge limits. The same factsheet lists the costs: high energy consumption and a constant electricity supply, high capital and operating costs, operation by skilled personnel, exposure to complicated chemical and microbiological problems, and the need for expert design and construction. It describes the process as highly mechanised and mainly suited to centralised systems where energy, spare parts and skilled labour are available.
Common misunderstandings
- SVI is not MLSS. MLSS is a concentration in mg/L; SVI is a volume per gram in mL/g after 30 minutes of settling, and it is calculated from MLSS.
- Sludge is not waste at every point in the loop. Return sludge is the working culture. Only the excess, waste activated sludge, leaves the process.
- There is no universal setting. The EPA monograph states there is no universal number for F/M, MCRT and similar parameters that works for every plant, so figures from another plant or a textbook are starting points for comparison, not targets.
- Secondary treatment limits are minimums. The 30 mg/L and 85 percent figures in 40 CFR 133.102 describe the minimum level attainable by secondary treatment, not what a well-operated plant is limited to producing.
- Settling removes the sludge, not every pollutant. SSWM notes that nutrient removal needs a set-up of aerated and non-aerated chambers rather than a single aerated tank.
Frequently asked questions
What is sludge in a water treatment plant?
In an activated sludge plant, sludge is the solid material that settles out of the water. It includes the working biological culture (activated sludge) that is returned to the aeration tank, and the surplus waste activated sludge and primary sludge that are removed for further sludge treatment.
What is the difference between MLSS and SVI?
MLSS is the concentration of suspended solids in the mixed liquor, in mg/L. SVI is the volume in millilitres occupied by one gram of those solids after 30 minutes of settling (EPA wastewater laboratory manual). SVI is calculated from the settled volume and MLSS, so the two are related but measure different things: biomass present versus settling behaviour.
What are the 7 steps in wastewater treatment?
The sources used here do not fix a seven-step list. The stages around an activated sludge unit are screening, primary settling, aeration, secondary clarification, sludge return and wasting, optional polishing and disinfection, and sludge treatment.
What are the different types of sludge?
In this process the types are activated sludge (the bacterial flocs), return sludge (settled solids sent back to the aeration tank), waste activated sludge (the excess removed), and primary sludge (from primary settling).
What does the activated sludge process remove?
SSWM describes it as removing aerobically biodegradable organic substances, effective for soluble, colloidal and particulate material, with designs that can also add nitrification, denitrification and biological phosphorus removal.
Sources
- Legal Information Institute, Cornell Law School: 40 CFR 133.102 Secondary treatment, checked 2026-11-19
- Eawag/SSWM: Activated Sludge factsheet, checked 2026-11-19
- US EPA NSCEP: Activated Sludge (Instructional Resources Monograph, 1973), checked 2026-11-19
- US EPA NSCEP: Wastewater Laboratory Procedures and Chemistry, Test 11 Settleability of Activated Sludge Solids, checked 2026-11-19
Data: Activated sludge process: effluent limits, design ranges and worked control calculations
Compiles the US secondary treatment effluent limits from 40 CFR 133.102, the design and operating ranges for activated sludge variants published by Eawag/SSWM and the EPA 1973 monograph, and three worked control calculations (solids inventory, return rate and sludge volume index) from EPA training documents. Each row cites the single source it was taken from.
Period covered: Sources read 2026-11-19.
| Parameter (unit) | Group | Value or range | Source |
|---|---|---|---|
| BOD5, 30-day average maximum (mg/L) | Secondary treatment limit (40 CFR 133.102) | 30 | 40 CFR 133.102(a)(1) |
| BOD5, 7-day average maximum (mg/L) | Secondary treatment limit (40 CFR 133.102) | 45 | 40 CFR 133.102(a)(2) |
| BOD5, minimum 30-day average removal (percent) | Secondary treatment limit (40 CFR 133.102) | 85 | 40 CFR 133.102(a)(3) |
| CBOD5 alternative, 30-day average maximum (mg/L) | Secondary treatment limit (40 CFR 133.102) | 25 | 40 CFR 133.102(a)(4) |
| CBOD5 alternative, 7-day average maximum (mg/L) | Secondary treatment limit (40 CFR 133.102) | 40 | 40 CFR 133.102(a)(4) |
| Suspended solids, 30-day average maximum (mg/L) | Secondary treatment limit (40 CFR 133.102) | 30 | 40 CFR 133.102(b) |
| Suspended solids, 7-day average maximum (mg/L) | Secondary treatment limit (40 CFR 133.102) | 45 | 40 CFR 133.102(b) |
| Effluent pH range | Secondary treatment limit (40 CFR 133.102) | 6.0 to 9.0 | 40 CFR 133.102(c) |
| Solids retention time for BOD removal (days) | Design range | 3 to 5 | Eawag/SSWM |
| Solids retention time for nitrification (days) | Design range | 3 to 18 | Eawag/SSWM |
| Settled sludge recirculation rate (percent) | Operating range | 20 to 100 | Eawag/SSWM |
| Oxidation ditch hydraulic retention time (hours) | Variant design range | 24 to 48 | Eawag/SSWM |
| Oxidation ditch sludge age (days) | Variant design range | 12 to 20 | Eawag/SSWM |
| Extended aeration basin detention period (hours) | Variant design range | 18 to 24 | EPA monograph, 1973 |
| Worked example: solids under aeration (lb), 780 mg/L x 0.55 MG x 8.34 | Worked calculation | 3588 | EPA monograph, 1973 (reported figure) |
| Worked example: return rate (MGD), 5.0 MGD x 18 percent | Worked calculation | 0.9 | EPA monograph, 1973 |
| Worked example: SVI (mL/g), 18 percent settled and MLSS 1,500 mg/L | Worked calculation | 120 | EPA laboratory manual, Test 11 (arithmetic recomputed) |
Sources
- 40 CFR 133.102 Secondary treatment (LII) (accessed 2026-11-19)
- Eawag/SSWM Activated Sludge factsheet (accessed 2026-11-19)
- US EPA Activated Sludge Instructional Resources Monograph (1973) (accessed 2026-11-19)
- US EPA Wastewater Laboratory Procedures and Chemistry, Test 11 (accessed 2026-11-19)
Compiled by CASRAI from the sources above. Free to reuse under CC BY 4.0 with attribution.