Skip to main content
v2026.11,986 entries · CC-BY 4.0
LAC HealthSponsored

Shop true draw lancet supplies

  • FDA registered
  • ISO 13485
  • BBB Accredited A+

Shop at LAC Health

True Draw Lancet (TRUEdraw Device): What FDA Cleared and Who Can Use It

True draw lancet means the TRUEdraw lancing device: what FDA cleared (K221072), five depth levels, and why it is for one patient at home.

Written and maintained by CASRAI Editorial Board

Published · Last updated

On this page

Quick answer: “True draw lancet” usually means the TRUEdraw Lancing Device from Trividia Health, a reusable spring-driven lancing device that holds a separate disposable lancet. FDA cleared it (510(k) K221072, decision date 2022-10-18) for multiple use by a single patient in a home setting, and states it is not suitable for healthcare professionals using it on multiple patients in a healthcare setting.

This page describes products and general use; it is not medical advice.

Who this is for: buyers, clinic and school staff and students who need to know what the device is, what FDA cleared it for, and which setting it belongs in. See also what a lancet is and blood sugar test lancets.

What it is: a lancing device, not a lancet

Two parts are easy to confuse. The lancing device is the reusable, pen-style holder. The lancet is the small sterile needle it holds, and it is a separate single-use item. CDC uses the term “fingerstick devices”, also called lancing devices, for the holders that prick the skin to obtain drops of blood for testing.

FDA’s summary describes the TRUEdraw device as “a reusable lancet base that uses compatible single-use, sterile lancets” to obtain a drop of blood from a fingertip or an alternative site (the forearm) using the clear end cap. Its stated indication is hygienic collection of capillary blood for testing purposes from the side of a fingertip and from alternative sites such as the forearm. Capillary collection in general is covered in capillary blood collection.

Who uses it: people testing their own blood at home, one person per device. It is over-the-counter, home-use equipment.

How it is built and operated

The FDA 510(k) summary lists these design points for the subject device:

  • Mechanical, spring-driven mechanism; plastic body with metal internal springs.
  • Depth adjustment in 5 levels by twisting the nozzle/end cap, with finer settings possible by placing the indicator arrow between the numbers.
  • An alternative-site clear cap is included in the cleared configuration.

The depth settings control how far the needle extends; they are separate from the lancet’s own gauge, which is explained in lancet gauge sizes.

What FDA cleared: the regulatory record

Item Record Source
Device name TRUEdraw Lancing Device / Mini Lancing Device FDA 510(k) database, K221072
Applicant Trividia Health, Inc. (Fort Lauderdale, Florida) FDA 510(k) summary
FDA classification name Multiple Use Blood Lancet For Single Patient Use Only FDA 510(k) database
Regulation 21 CFR 878.4850, Blood lancets FDA clearance letter
Class and product code Class II; product code QRL FDA clearance letter and database
Decision Substantially Equivalent, 2022-10-18 (received 2022-04-12) FDA 510(k) database
Predicate device Accu-Chek Softclix lancing device (K214022) FDA 510(k) summary
Difference from predicate Forearm is the only alternative site listed; the predicate lists palm, upper arm and forearm FDA 510(k) summary
Setting and users Single patient, home setting; multiple uses by that one patient FDA 510(k) summary

A 510(k) “substantially equivalent” decision means FDA found the device substantially equivalent to a predicate. It is not an approval of a specific lancet brand. The summary also reports bench testing under the special controls of 21 CFR 878.4850(c), including that the lancet blade can be manually changed with every use, and a compatibility check against commonly available general-use lancets (lancet body diameter, exposed needle length, body length and fit).

Who may use it

FDA’s summary says the device is “for use only on a single patient in a home setting” and is not suitable for use by healthcare professionals with multiple patients in a healthcare setting. CDC’s guidance for glucose monitoring points the same way: “Never use fingerstick devices for more than one person”, and “Never reuse lancets.” CDC recommends that providers label fingerstick devices and use them on a single patient only, and says single-use, auto-disabling fingerstick devices should be used in settings where assisted blood glucose monitoring is performed.

That gives a plain decision point for clinics, schools and care facilities: a reusable home lancing device cleared for one patient is a different product class from the single-use, auto-disabling devices CDC describes for assisted monitoring. Learn more about sharps handling in FDA-cleared sharps containers.

How to verify before you buy or stock it

Each item below is something a supplier or manufacturer can document:

  • The 510(k) number and indication. Look up K221072 in FDA’s 510(k) database and confirm the cleared indication matches your use (single patient, home).
  • The manufacturer’s instructions for use. Ask for the current IFU for the device and for the lancets you plan to pair with it.
  • A written lancet compatibility statement. The FDA summary reports compatibility with commonly available general-use lancets, but fit depends on the specific lancet’s dimensions, so get compatibility confirmed in writing for the exact lancet.
  • Lot and expiry information on the lancets. See do lancets expire.

Catalogue listings for diagnostic and monitoring supplies are available under diagnostic, monitoring and imaging supplies.

Safe use and handling basics

  • One device, one person. Do not share it or lend it, including with family members.
  • Use a new lancet each time; CDC says never reuse lancets.
  • CDC advises wearing gloves during blood glucose monitoring, and dedicated or disinfected meters between people.
  • Put used lancets in an approved sharps container.

Follow the manufacturer’s instructions for use for loading, depth setting and cleaning. Questions about your own testing belong with your clinician.

Common mistakes

  • Calling the device a lancet. The device and the needle are separate items, bought and replaced separately.
  • Using one lancing device on several people. The cleared labeling is single patient, home setting; CDC says never to use fingerstick devices for more than one person.
  • Reusing a lancet. CDC says never reuse lancets.
  • Assuming any lancet is cleared with it. FDA reports compatibility testing with commonly available general-use lancets; it does not list every lancet brand.

FAQ

What is a true draw lancet?

The phrase usually refers to the TRUEdraw Lancing Device from Trividia Health. Strictly, the device is the lancing device and the lancet is the disposable needle it holds.

What is the true draw lancet device cleared for?

Hygienic collection of capillary blood for testing from the side of a fingertip and from alternative sites such as the forearm, by a single patient in a home setting (FDA K221072).

Is it Class I or Class II?

Class II, under 21 CFR 878.4850, product code QRL.

Can a clinic or school nurse use it on several people?

No. FDA’s summary says it is not suitable for use by healthcare professionals with multiple patients in a healthcare setting, and CDC says never to use fingerstick devices for more than one person.

How many depth settings does it have?

Five levels, set by twisting the nozzle/end cap, with finer adjustment between numbers. See also what a glucometer is and glucose test strips.

Sources

Follow CASRAI

Research-administration guidance, standards updates and independent tool reviews.

Ask CASRAI · free to try

Ask about True Draw Lancet (TRUEdraw Device): What FDA Cleared and Who Can Use It

2 free questions a day, no account.

An AI assistant for research: funder rules, compliance, methods and publishing. It links the sources behind its answers and labels answers that come from a web search.

Answers draw on CASRAI's guides and dictionary plus the federal and funder documents we index: Federal Register, Grants.gov, Regulations.gov and UKRI.

Works on this site and inside Claude, Cursor and the AI tools you already use.

Everything CASRAI publishes — this page, the dictionary, the guides and the news — stays open to read, with no account and no card.

Referenced across the research world

University of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logoUniversity of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logo
  • University of Cambridge logo
  • Columbia University logo
  • Crossref logo
  • University of Edinburgh logo
  • Harvard University logo
  • University of Oxford logo
  • Princeton University logo
  • Stanford School of Medicine logo
  • University College London logo
  • ORCID logo

View CASRAI adoption →