Skip to main content
v2026.11,986 entries · CC-BY 4.0
LAC HealthSponsored

Shop aspiration pipette supplies

  • FDA registered
  • ISO 13485
  • BBB Accredited A+

Shop at LAC Health

Aspiration Pipette: What It Is, Types and Safe Use

What an aspiration pipette is, how the ungraduated vacuum-line pipet differs from the micromanipulation tool, and the aspiration system around it.

Written and maintained by CASRAI Editorial Board

Published

On this page

An aspiration pipette is a disposable, usually polystyrene pipet with no graduations and no filter plug that is attached to vacuum tubing to pull liquid out of a vessel, such as spent medium from a culture dish. The same words are also used for a different tool, a hand-held micro-pipette fitted with a finger-controlled bulb that draws cells or other small material into the tip during micromanipulation. Most catalogue searches mean the first sense, and this guide covers both so you can tell which one a listing describes.

What an aspiration pipette is

In its common laboratory sense, an aspiration pipette (also written aspirating pipette, aspirator pipette or aspiration pipet) is a removal tool, not a measuring tool. Greiner Bio-One’s CELLSTAR 2 mL aspiration pipet, as listed by USA Scientific, states that these pipettes do not have graduations or filter plugs, and that aspirating pipettes can be used with vacuum tubing for quick and easy liquid removal. Sarstedt describes its 2 mL aspiration pipette in similar terms: it is listed as unplugged, sterile, non-pyrogenic (endotoxin-free) and non-cytotoxic, and is meant for transferring liquid where precision is not needed and for aspirating liquids with a vacuum pump.

Who uses it: staff in tissue culture and cell biology laboratories who remove medium or wash buffer from flasks, plates and dishes, and technicians who set up and maintain vacuum aspiration stations. The second sense of the term is used by embryology and micromanipulation workers, described below.

This is the main difference from a serological pipette, which carries a printed scale and often a cotton plug because it is used to measure and dispense volumes. If you are looking for the measuring tools, start with what a pipette is; this page is about the removal tool that sits at the end of a vacuum line.

How it is built and how the system works

The pipettes described by the manufacturers above share a short list of features. Each is made of polystyrene, supplied sterile, and wrapped individually. Greiner’s 2 mL product is listed as individually wrapped and sold 1,000 to a case; Sarstedt lists one pipette per blister; Corning’s Falcon aspirating pipets, as listed by Genesee Scientific, are individually wrapped in thermoformed paper-plastic wrap and sold 200 to a case. Genesee also states that the Falcon pipets are noncytotoxic and nonpyrogenic, tested to less than 0.1 EU/ml, and describes them as a safer option than glass.

The absence of graduations and of a plug follows from the job. Because the pipette never measures anything, printing is unnecessary, and because liquid is moving away from the user into a collection vessel, there is no pipetting bulb or pump at the proximal end. The user instead pushes the wide end onto tubing connected to a vacuum source. Genesee’s listing for the Falcon pipets says they can be used for all vacuum-aspirating procedures.

The aspiration system behind the pipette

The pipette is only the visible part of the setup. The University of South Florida’s biosafety office describes a vacuum aspiration system as a chain: the pipette and tubing lead to a collection flask, then to an overflow flask, then to an in-line hydrophobic HEPA filter in front of the vacuum source. USF states that the collection flask should be sized to the volume it will receive, that the overflow flask should contain disinfectant, that a secondary container should hold the flasks, and that the primary flask should be filled to no more than about two thirds. USF also cites the CDC’s Biosafety in Microbiological Laboratories (BMBL, 6th edition), which calls for vacuum lines at biosafety level 2 to be protected with liquid disinfectant traps.

Types and variants

The term covers a small number of distinct products. The table below separates them by what they are used for and what makes each different.

Type Typical use Key difference Source
Disposable aspirating pipet, 2 mL Removing liquid through vacuum tubing No graduations, no filter plug, sterile, individually wrapped (Greiner CELLSTAR) USA Scientific listing
Disposable aspiration pipette with tip, 2 mL Transferring liquid without a need for precision, and vacuum-pump aspiration Unplugged, sterile, non-pyrogenic and non-cytotoxic (Sarstedt) Sarstedt product page
Disposable aspirating pipets, 2 mL and 5 mL Vacuum-aspirating procedures and sterile aspirating or dispensing of non-toxic solutions Non-graduated, non-plugged, offered in two sizes (Corning Falcon) Genesee Scientific listing
Hand-held aspiration pipette for micromanipulation Drawing sample media into a micro-pipette, for example in IVF and ICSI work A finger-fitted elastomer ring with an aspirating bulb lets the operator control volume, placement and speed (US patent 8273009) Google Patents

Aspirator pipette

Aspirator pipette is a naming variant. Suppliers file the same ungraduated vacuum-line products under aspirating, aspiration and aspirator wording, so a search under any of them returns the same product class. The patent literature uses aspiration for the hand-held device instead.

Pipette aspiration as an action

Pipette aspiration also names the act of drawing liquid up into a pipette or tip, which is a general pipetting step covered in the guide to reverse pipetting and the other pipette pages on this site. That meaning has no connection with the vacuum-line product described here, so check the context of a listing before assuming which one it means.

The micromanipulation aspiration device

US patent 8273009, titled Pipette aspiration device, describes an elastomer ring that fits on a finger together with an aspirating bulb, used to aspirate sample media into a micro-pipette during micromanipulation. The patent lists in vitro fertilisation and intracytoplasmic sperm injection among its applications, including handling of oocyte-cumulus complexes and denuding. It says the operator controls the volume, placement and speed of aspiration. The patent does not define aspiration pipette as a term, and this is a description of one patented device, not a general standard for the category.

Sizes and specifications that matter

The manufacturer listings give few numbers, and the data table below records only the values they state. Volume is nominal: since the pipettes are not graduated, a 2 mL or 5 mL label describes the pipette’s capacity class, not a scale you can read. The only length stated in any of the listings is 13.71 in. for the 5 mL Falcon pipet; no length is given for the 2 mL products, so confirm the length against the manufacturer’s current specification before matching a pipette to a flask neck or hood height.

The properties that the sources treat as defining are the following.

  • Graduations: none. Greiner and Genesee both say so explicitly.
  • Plug: none. Greiner, Sarstedt and Genesee all list the pipettes as unplugged.
  • Sterility: sterile, individually packed.
  • Endotoxin and cytotoxicity: Sarstedt lists non-pyrogenic, endotoxin-free and non-cytotoxic; Genesee states noncytotoxic and nonpyrogenic, tested to less than 0.1 EU/ml.
  • Material: polystyrene.

How to choose

The sources do not publish a selection standard, so the criteria below are limited to what the product listings themselves say about intended use.

  • Removing liquid versus measuring it. Greiner and Sarstedt describe their pipettes as removal tools, Sarstedt noting that precision is not needed. If you must deliver a defined volume, an ungraduated aspiration pipette is the wrong product class; see sterile pipettes for the measuring family.
  • Sterile work. Genesee recommends the Falcon pipets for tissue culture and for non-toxic solutions that need to be aspirated or dispensed in a sterile environment, and all three suppliers list sterile products. Check that the product you are ordering carries the sterility statement you need.
  • Pyrogen and cytotoxicity statements. Where your protocol needs endotoxin-free or non-cytotoxic consumables, compare the statements on the listing, since Sarstedt and Genesee state them and the Greiner listing does not.
  • Size. The sources offer 2 mL (Greiner, Sarstedt, Corning) and 5 mL (Corning). Capacity and length are separate questions; see the specification section above.
  • Tip-style products. Sarstedt lists its aspiration pipette as supplied with a tip. A related but different device is the Beral pipette, a transfer pipette that is squeezed by hand rather than connected to vacuum.

Safe use and handling basics

Aspirated liquid from cell culture can carry biological material, so the safety question belongs to the whole system, not to the pipette. The USF guidance summarised here is a single institution’s published practice, and it cites the CDC’s BMBL; your own institution’s biosafety office decides what applies in your laboratory.

  • Protect the vacuum line. USF describes the collection flask feeding an overflow flask with disinfectant and then an in-line hydrophobic HEPA filter, and notes that BMBL calls for liquid disinfectant traps on vacuum lines at BSL-2.
  • Do not overfill. USF says to fill the primary flask to no more than about two thirds, and to size flasks to the expected volume.
  • Disinfect the collected liquid. USF specifies a 10 percent final bleach concentration, with 9 parts tissue-culture medium to 1 part bleach and 30 minutes of contact time before the liquid goes down the drain. It also notes that antifoam is needed because foam will shut off the vacuum.
  • Watch the filter. USF says to replace a hydrophobic filter that is wet or clogged, and to clamp the line before removing the filter or a flask.
  • Use a fresh sterile pipette. The pipettes are sold sterile and individually wrapped, which suits single use. Open the wrapping only when the pipette is needed.

The hand-held micromanipulation device is operated by trained clinical or embryology staff. Step-by-step use of it is outside the scope of this page.

Common mistakes

  • Treating the 2 mL label as a measuring scale. The pipettes carry no graduations, so they cannot be used to dispense an accurate volume.
  • Connecting the pipette to bare vacuum. Without the flask, disinfectant overflow trap and in-line filter described by USF, aspirated liquid can reach the building vacuum.
  • Letting the collection flask fill past about two thirds, which USF’s guidance warns against.
  • Ignoring foam. USF states foam will shut off the vacuum, so use antifoam where it is likely.
  • Mixing the two senses of the term. A patented hand-held aspiration device for micromanipulation and a disposable vacuum-line pipet are unrelated products that share a name. Do not buy or specify one from a listing that describes the other.
  • Confusing it with other devices. An aspiration needle (see what an aspiration needle is) is a different instrument, and so is a pipette pump (pipette pumps), which drives measuring pipettes.

Sources

Data: Stated specifications of disposable aspirating pipettes from three manufacturers' listings

Specifications of ungraduated aspirating pipettes (Greiner CELLSTAR, Sarstedt, Corning Falcon) compiled from manufacturer and distributor listings; only values the listings state are included, and not-stated marks gaps.

Stated specifications of disposable aspirating pipettes from three manufacturers' listings
ProductNominal volume (mL)MaterialSterileGraduationsPlugPackagingStated length (in)
Greiner CELLSTAR aspiration pipet2PolystyreneYesNoneNone (no filter plug)Individually wrapped, 1000 per casenot stated
Sarstedt aspiration pipette with tip, 86.1252.0112PolystyreneYesnot statedUnplugged1 per blisternot stated
Corning Falcon aspirating pipet, 12-3202PolystyreneYesNone (non-graduated)None (non-plugged)Individually wrapped, 200 per casenot stated
Corning Falcon aspirating pipet, 12-3235PolystyreneYesNone (non-graduated)None (non-plugged)Individually wrapped, 200 per case13.71

Sources

Compiled by CASRAI from the sources above. Free to reuse under CC BY 4.0 with attribution.

Follow CASRAI

Research-administration guidance, standards updates and independent tool reviews.

Ask CASRAI · free to try

Ask about Aspiration Pipette: What It Is, Types and Safe Use

2 free questions a day, no account.

An AI assistant for research: funder rules, compliance, methods and publishing. It links the sources behind its answers and labels answers that come from a web search.

Answers draw on CASRAI's guides and dictionary plus the federal and funder documents we index: Federal Register, Grants.gov, Regulations.gov and UKRI.

Works on this site and inside Claude, Cursor and the AI tools you already use.

Everything CASRAI publishes — this page, the dictionary, the guides and the news — stays open to read, with no account and no card.

Referenced across the research world

University of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logoUniversity of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logo
  • University of Cambridge logo
  • Columbia University logo
  • Crossref logo
  • University of Edinburgh logo
  • Harvard University logo
  • University of Oxford logo
  • Princeton University logo
  • Stanford School of Medicine logo
  • University College London logo
  • ORCID logo

View CASRAI adoption →